copy

Return to an address of the Honourable the House of Commons, dated 5 May 1868, for: copy of correspondence and papers relating to the establishment of telegraphic communication between India, Singapore, China and Australia, since the 21st day of February

Archives, Room Use Only - HE8374.G74 1868




copy

Quantification of the mixed-valence and intervalence charge transfer properties of a cofacial metal–organic framework via single crystal electronic absorption spectroscopy

Chem. Sci., 2020, Advance Article
DOI: 10.1039/D0SC01521K, Edge Article
Open Access
Patrick W. Doheny, Jack K. Clegg, Floriana Tuna, David Collison, Cameron J. Kepert, Deanna M. D'Alessandro
Gaining a fundamental understanding of charge transfer mechanisms in three-dimensional Metal–Organic Frameworks (MOFs) is crucial to the development of electroactive and conductive porous materials.
To cite this article before page numbers are assigned, use the DOI form of citation above.
The content of this RSS Feed (c) The Royal Society of Chemistry




copy

A versatile nanoreactor for complementary in situ X-ray and electron microscopy studies in catalysis and materials science

Two in situ `nanoreactors' for high-resolution imaging of catalysts have been designed and applied at the hard X-ray nanoprobe endstation at beamline P06 of the PETRA III synchrotron radiation source. The reactors house samples supported on commercial MEMS chips, and were applied for complementary hard X-ray ptychography (23 nm spatial resolution) and transmission electron microscopy, with additional X-ray fluorescence measurements. The reactors allow pressures of 100 kPa and temperatures of up to 1573 K, offering a wide range of conditions relevant for catalysis. Ptychographic tomography was demonstrated at limited tilting angles of at least ±35° within the reactors and ±65° on the naked sample holders. Two case studies were selected to demonstrate the functionality of the reactors: (i) annealing of hierarchical nanoporous gold up to 923 K under inert He environment and (ii) acquisition of a ptychographic projection series at ±35° of a hierarchically structured macroporous zeolite sample under ambient conditions. The reactors are shown to be a flexible and modular platform for in situ studies in catalysis and materials science which may be adapted for a range of sample and experiment types, opening new characterization pathways in correlative multimodal in situ analysis of functional materials at work. The cells will presently be made available for all interested users of beamline P06 at PETRA III.




copy

A portable on-axis laser-heating system for near-90° X-ray spectroscopy: application to ferropericlase and iron silicide

A portable IR fiber laser-heating system, optimized for X-ray emission spectroscopy (XES) and nuclear inelastic scattering (NIS) spectroscopy with signal collection through the radial opening of diamond anvil cells near 90°with respect to the incident X-ray beam, is presented. The system offers double-sided on-axis heating by a single laser source and zero attenuation of incoming X-rays other than by the high-pressure environment. A description of the system, which has been tested for pressures above 100 GPa and temperatures up to 3000 K, is given. The XES spectra of laser-heated Mg0.67Fe0.33O demonstrate the potential to map the iron spin state in the pressure–temperature range of the Earth's lower mantle, and the NIS spectra of laser-heated FeSi give access to the sound velocity of this candidate of a phase inside the Earth's core. This portable system represents one of the few bridges across the gap between laser heating and high-resolution X-ray spectroscopies with signal collection near 90°.




copy

Limited angle tomography for transmission X-ray microscopy using deep learning

In transmission X-ray microscopy (TXM) systems, the rotation of a scanned sample might be restricted to a limited angular range to avoid collision with other system parts or high attenuation at certain tilting angles. Image reconstruction from such limited angle data suffers from artifacts because of missing data. In this work, deep learning is applied to limited angle reconstruction in TXMs for the first time. With the challenge to obtain sufficient real data for training, training a deep neural network from synthetic data is investigated. In particular, U-Net, the state-of-the-art neural network in biomedical imaging, is trained from synthetic ellipsoid data and multi-category data to reduce artifacts in filtered back-projection (FBP) reconstruction images. The proposed method is evaluated on synthetic data and real scanned chlorella data in 100° limited angle tomography. For synthetic test data, U-Net significantly reduces the root-mean-square error (RMSE) from 2.55 × 10−3 µm−1 in the FBP reconstruction to 1.21 × 10−3 µm−1 in the U-Net reconstruction and also improves the structural similarity (SSIM) index from 0.625 to 0.920. With penalized weighted least-square denoising of measured projections, the RMSE and SSIM are further improved to 1.16 × 10−3 µm−1 and 0.932, respectively. For real test data, the proposed method remarkably improves the 3D visualization of the subcellular structures in the chlorella cell, which indicates its important value for nanoscale imaging in biology, nanoscience and materials science.




copy

X-ray photon correlation spectroscopy of protein dynamics at nearly diffraction-limited storage rings

This study explores the possibility of measuring the dynamics of proteins in solution using X-ray photon correlation spectroscopy (XPCS) at nearly diffraction-limited storage rings (DLSRs). We calculate the signal-to-noise ratio (SNR) of XPCS experiments from a concentrated lysozyme solution at the length scale of the hydrodynamic radius of the protein molecule. We take into account limitations given by the critical X-ray dose and find expressions for the SNR as a function of beam size, sample-to-detector distance and photon energy. Specifically, we show that the combined increase in coherent flux and coherence lengths at the DLSR PETRA IV yields an increase in SNR of more than one order of magnitude. The resulting SNR values indicate that XPCS experiments of biological macromolecules on nanometre length scales will become feasible with the advent of a new generation of synchrotron sources. Our findings provide valuable input for the design and construction of future XPCS beamlines at DLSRs.




copy

DeepRes: a new deep-learning- and aspect-based local resolution method for electron-microscopy maps

In this article, a method is presented to estimate a new local quality measure for 3D cryoEM maps that adopts the form of a `local resolution' type of information. The algorithm (DeepRes) is based on deep-learning 3D feature detection. DeepRes is fully automatic and parameter-free, and avoids the issues of most current methods, such as their insensitivity to enhancements owing to B-factor sharpening (unless the 3D mask is changed), among others, which is an issue that has been virtually neglected in the cryoEM field until now. In this way, DeepRes can be applied to any map, detecting subtle changes in local quality after applying enhancement processes such as isotropic filters or substantially more complex procedures, such as model-based local sharpening, non-model-based methods or denoising, that may be very difficult to follow using current methods. It performs as a human observer expects. The comparison with traditional local resolution indicators is also addressed.




copy

Hypothesis for a mechanism of beam-induced motion in cryo-electron microscopy

Estimates of heat-transfer rates during plunge-cooling and the patterns of ice observed in cryo-EM samples indicate that the grid bars cool much more slowly than do the support foil and sample near the middle of the grid openings. The resulting transient temperature differences generate transient tensile stresses in the support foil. Most of this foil stress develops while the sample is liquid and cooling toward its glass transition Tg, and so does not generate tensile sample stress. As the grid bars continue cooling towards the cryogen temperature and contracting, the tensile stress in the foil is released, placing the sample in compressive stress. Radiation-induced creep in the presence of this compressive stress should generate a doming of the sample in the foil openings, as is observed experimentally. Crude estimates of the magnitude of the doming that may be generated by this mechanism are consistent with observation. Several approaches to reducing beam-induced motion are discussed.




copy

Scanning electron microscopy as a method for sample visualization in protein X-ray crystallography

Developing methods to determine high-resolution structures from micrometre- or even submicrometre-sized protein crystals has become increasingly important in recent years. This applies to both large protein complexes and membrane proteins, where protein production and the subsequent growth of large homogeneous crystals is often challenging, and to samples which yield only micro- or nanocrystals such as amyloid or viral polyhedrin proteins. The versatile macromolecular crystallography microfocus (VMXm) beamline at Diamond Light Source specializes in X-ray diffraction measurements from micro- and nanocrystals. Because of the possibility of measuring data from crystalline samples that approach the resolution limit of visible-light microscopy, the beamline design includes a scanning electron microscope (SEM) to visualize, locate and accurately centre crystals for X-ray diffraction experiments. To ensure that scanning electron microscopy is an appropriate method for sample visualization, tests were carried out to assess the effect of SEM radiation on diffraction quality. Cytoplasmic polyhedrosis virus polyhedrin protein crystals cryocooled on electron-microscopy grids were exposed to SEM radiation before X-ray diffraction data were collected. After processing the data with DIALS, no statistically significant difference in data quality was found between datasets collected from crystals exposed and not exposed to SEM radiation. This study supports the use of an SEM as a tool for the visualization of protein crystals and as an integrated visualization tool on the VMXm beamline.




copy

New zeolite-like RUB-5 and its related hydrous layer silicate RUB-6 structurally characterized by electron microscopy

This study made use of a recently developed combination of advanced methods to reveal the atomic structure of a disordered nanocrystalline zeolite using exit wave reconstruction, automated diffraction tomography, disorder modelling and diffraction pattern simulation. By applying these methods, it was possible to determine the so far unknown structures of the hydrous layer silicate RUB-6 and the related zeolite-like material RUB-5. The structures of RUB-5 and RUB-6 contain the same dense layer-like building units (LLBUs). In the case of RUB-5, these building units are interconnected via additional SiO4/2 tetrahedra, giving rise to a framework structure with a 2D pore system consisting of intersecting 8-ring channels. In contrast, RUB-6 contains these LLBUs as separate silicate layers terminated by silanol/sil­oxy groups. Both RUB-6 and RUB-5 show stacking disorder with intergrowths of different polymorphs. The unique structure of RUB-6, together with the possibility for an interlayer expansion reaction to form RUB-5, make it a promising candidate for interlayer expansion with various metal sources to include catalytically active reaction centres.




copy

CM01: a facility for cryo-electron microscopy at the European Synchrotron

Recent improvements in direct electron detectors, microscope technology and software provided the stimulus for a `quantum leap' in the application of cryo-electron microscopy in structural biology, and many national and international centres have since been created in order to exploit this. Here, a new facility for cryo-electron microscopy focused on single-particle reconstruction of biological macromolecules that has been commissioned at the European Synchrotron Radiation Facility (ESRF) is presented. The facility is operated by a consortium of institutes co-located on the European Photon and Neutron Campus and is managed in a similar fashion to a synchrotron X-ray beamline. It has been open to the ESRF structural biology user community since November 2017 and will remain open during the 2019 ESRF–EBS shutdown.




copy

Methods for merging data sets in electron cryo-microscopy

Recent developments have resulted in electron cryo-microscopy (cryo-EM) becoming a useful tool for the structure determination of biological macromolecules. For samples containing inherent flexibility, heterogeneity or preferred orientation, the collection of extensive cryo-EM data using several conditions and microscopes is often required. In such a scenario, merging cryo-EM data sets is advantageous because it allows improved three-dimensional reconstructions to be obtained. Since data sets are not always collected with the same pixel size, merging data can be challenging. Here, two methods to combine cryo-EM data are described. Both involve the calculation of a rescaling factor from independent data sets. The effects of errors in the scaling factor on the results of data merging are also estimated. The methods described here provide a guideline for cryo-EM users who wish to combine data sets from the same type of microscope and detector.




copy

Flexible workflows for on-the-fly electron-microscopy single-particle image processing using Scipion

Electron microscopy of macromolecular structures is an approach that is in increasing demand in the field of structural biology. The automation of image acquisition has greatly increased the potential throughput of electron microscopy. Here, the focus is on the possibilities in Scipion to implement flexible and robust image-processing workflows that allow the electron-microscope operator and the user to monitor the quality of image acquisition, assessing very simple acquisition measures or obtaining a first estimate of the initial volume, or the data resolution and heterogeneity, without any need for programming skills. These workflows can implement intelligent automatic decisions and they can warn the user of possible acquisition failures. These concepts are illustrated by analysis of the well known 2.2 Å resolution β-galactosidase data set.




copy

XTIP – the world's first beamline dedicated to the synchrotron X-ray scanning tunneling microscopy technique

In recent years, there have been numerous efforts worldwide to develop the synchrotron X-ray scanning tunneling microscopy (SX-STM) technique. Here, the inauguration of XTIP, the world's first beamline fully dedicated to SX-STM, is reported. The XTIP beamline is located at Sector 4 of the Advanced Photon Source at Argonne National Laboratory. It features an insertion device that can provide left- or right-circular as well as horizontal- and vertical-linear polarization. XTIP delivers monochromatic soft X-rays of between 400 and 1900 eV focused into an environmental enclosure that houses the endstation instrument. This article discusses the beamline system design and its performance.




copy

Versatile compact heater design for in situ nano-tomography by transmission X-ray microscopy

A versatile, compact heater designed at National Synchrotron Light Source-II for in situ X-ray nano-imaging in a full-field transmission X-ray microscope is presented. Heater design for nano-imaging is challenging, combining tight spatial constraints with stringent design requirements for the temperature range and stability. Finite-element modeling and analytical calculations were used to determine the heater design parameters. Performance tests demonstrated reliable and stable performance, including maintaining the exterior casing close to room temperature while the heater is operating at above 1100°C, a homogenous heating zone and small temperature fluctuations. Two scientific experiments are presented to demonstrate the heater capabilities: (i) in situ 3D nano-tomography including a study of metal dealloying in a liquid molten salt extreme environment, and (ii) a study of pore formation in icosahedral quasicrystals. The progression of structural changes in both studies were clearly resolved in 3D, showing that the new heater enables powerful capabilities to directly visualize and quantify 3D morphological evolution of materials under real conditions by X-ray nano-imaging at elevated temperature during synthesis, fabrication and operation processes. This heater design concept can be applied to other applications where a precise, compact heater design is required.




copy

LamNI – an instrument for X-ray scanning microscopy in laminography geometry

Across all branches of science, medicine and engineering, high-resolution microscopy is required to understand functionality. Although optical methods have been developed to `defeat' the diffraction limit and produce 3D images, and electrons have proven ever more useful in creating pictures of small objects or thin sections, so far there is no substitute for X-ray microscopy in providing multiscale 3D images of objects with a single instrument and minimal labeling and preparation. A powerful technique proven to continuously access length scales from 10 nm to 10 µm is ptychographic X-ray computed tomography, which, on account of the orthogonality of the tomographic rotation axis to the illuminating beam, still has the limitation of necessitating pillar-shaped samples of small (ca 10 µm) diameter. Large-area planar samples are common in science and engineering, and it is therefore highly desirable to create an X-ray microscope that can examine such samples without the extraction of pillars. Computed laminography, where the axis of rotation is not perpendicular to the illumination direction, solves this problem. This entailed the development of a new instrument, LamNI, dedicated to high-resolution 3D scanning X-ray microscopy via hard X-ray ptychographic laminography. Scanning precision is achieved by a dedicated interferometry scheme and the instrument covers a scan range of 12 mm × 12 mm with a position stability of 2 nm and positioning errors below 5 nm. A new feature of LamNI is a pair of counter-rotating stages carrying the sample and interferometric mirrors, respectively.




copy

Identification of Ca-rich dense granules in human platelets using scanning transmission X-ray microscopy

Whole-mount (WM) platelet preparation followed by transmission electron microscopy (TEM) observation is the standard method currently used to assess dense granule (DG) deficiency (DGD). However, due to the electron-density-based contrast mechanism in TEM, other granules such as α-granules might cause false DG detection. Here, scanning transmission X-ray microscopy (STXM) was used to identify DGs and minimize false DG detection of human platelets. STXM image stacks of human platelets were collected at the calcium (Ca) L2,3 absorption edge and then converted to optical density maps. Ca distribution maps, obtained by subtracting the optical density maps at the pre-edge region from those at the post-edge region, were used to identify DGs based on the Ca richness. DGs were successfully detected using this STXM method without false detection, based on Ca maps for four human platelets. Spectral analysis of granules in human platelets confirmed that DGs contain a richer Ca content than other granules. The Ca distribution maps facilitated more effective DG identification than TEM which might falsely detect DGs. Correct identification of DGs would be important to assess the status of platelets and DG-related diseases. Therefore, this STXM method is proposed as a promising approach for better DG identification and diagnosis, as a complementary tool to the current WM TEM approach.




copy

A design of resonant inelastic X-ray scattering (RIXS) spectrometer for spatial- and time-resolved spectroscopy

The optical design of a Hettrick–Underwood-style soft X-ray spectrometer with Wolter type 1 mirrors is presented. The spectrometer with a nominal length of 3.1 m can achieve a high resolving power (resolving power higher than 10000) in the soft X-ray regime when a small source beam (<3 µm in the grating dispersion direction) and small pixel detector (5 µm effective pixel size) are used. Adding Wolter mirrors to the spectrometer before its dispersive elements can realize the spatial imaging capability, which finds applications in the spectroscopic studies of spatially dependent electronic structures in tandem catalysts, heterostructures, etc. In the pump–probe experiments where the pump beam perturbs the materials followed by the time-delayed probe beam to reveal the transient evolution of electronic structures, the imaging capability of the Wolter mirrors can offer the pixel-equivalent femtosecond time delay between the pump and probe beams when their wavefronts are not collinear. In combination with some special sample handing systems, such as liquid jets and droplets, the imaging capability can also be used to study the time-dependent electronic structure of chemical transformation spanning multiple time domains from microseconds to nanoseconds. The proposed Wolter mirrors can also be adopted to the existing soft X-ray spectrometers that use the Hettrick–Underwood optical scheme, expanding their capabilities in materials research.




copy

Fluorescence-detected quick-scanning X-ray absorption spectroscopy

Time-resolved X-ray absorption spectroscopy (XAS) offers the possibility to monitor the state of materials during chemical reactions. While this technique has been established for transmission measurements for a number of years, XAS measurements in fluorescence mode are challenging because of limitations in signal collection as well as detectors. Nevertheless, measurements in fluorescence mode are often the only option to study complex materials containing heavy matrices or in samples where the element of interest is in low concentration. Here, it has been demonstrated that high-quality quick-scanning full extended X-ray absorption fine-structure data can be readily obtained with sub-second time resolution in fluorescence mode, even for highly diluted samples. It has also been demonstrated that in challenging samples, where transmission measurements are not feasible, quick fluorescence can yield significant insight in reaction kinetics. By studying the fast high-temperature oxidation of a reduced LaFe0.8Ni0.8O3 perovskite type, an example where the perovskite matrix elements prevent measurements in fluorescence, it is shown that it is now possible to follow the state of Ni in situ at a 3 s time resolution.




copy

Correlative vibrational spectroscopy and 2D X-ray diffraction to probe the mineralization of bone in phosphate-deficient mice

Bone crystallite chemistry and structure change during bone maturation. However, these properties of bone can also be affected by limited uptake of the chemical constituents of the mineral by the animal. This makes probing the effect of bone-mineralization-related diseases a complicated task. Here it is shown that the combination of vibrational spectroscopy with two-dimensional X-ray diffraction can provide unparalleled information on the changes in bone chemistry and structure associated with different bone pathologies (phosphate deficiency) and/or health conditions (pregnancy, lactation). Using a synergistic analytical approach, it was possible to trace the effect that changes in the remodelling regime have on the bone mineral chemistry and structure in normal and mineral-deficient (hypophosphatemic) mice. The results indicate that hypophosphatemic mice have increased bone remodelling, increased carbonate content and decreased crystallinity of the bone mineral, as well as increased misalignment of crystallites within the bone tissue. Pregnant and lactating mice that are normal and hypophosphatemic showed changes in the chemistry and misalignment of the apatite crystals that can be related to changes in remodelling rates associated with different calcium demand during pregnancy and lactation.




copy

New attempt to combine scanning electron microscopy and small-angle scattering in reciprocal space

An attempt has been made to combine small-angle scattering of X-rays or neutrons with scanning electron microscopy in reciprocal space, in order to establish a structural analysis method covering a wide range of sizes from micro- to macro-scales.




copy

A closer look at superionic phase transition in (NH4)4H2(SeO4)3: impedance spectroscopy under pressure

The proton-conducting material (NH4)4H2(SeO4)3 is examined to check whether its conductivity spectra are sensitive to subtle changes in the crystal structure and proton dynamics caused by external pressure. The AC conductivity was measured using impedance spectroscopy, in the frequency range from 100 Hz to 1 MHz, at temperatures 260 K < T < 400 K and pressures 0.1 MPa < p < 500 MPa. On the basis of the impedance spectra, carefully analyzed at different thermodynamic conditions, the p–T phase diagram of the crystal is constructed. It is found to be linear in the pressure range of the experiment, with the pressure coefficient value dTs/dp = −0.023 K MPa−1. The hydrostatic pressure effect on proton conductivity is also presented and discussed. Measurements of the electrical conductivity versus time were performed at a selected temperature T = 352.3 K and at pressures 0.1 MPa < p < 360 MPa. At fixed thermodynamic conditions (p = 302 MPa, T = 352.3 K), the sluggish solid–solid transformation from low conducting to superionic phase was induced. It is established that the kinetics of this transformation can be described by the Avrami model with an effective Avrami index value of about 4, which corresponds to the classical value associated with the homogeneous nucleation and three-dimensional growth of a new phase.




copy

A closer look at superionic phase transition in (NH4)4H2(SeO4)3: impedance spectroscopy under pressure

The proton-conducting crystal (NH4)4H2(SeO4)3 is examined to check whether its conductivity spectra and the phase transition to the superprotonic phase are sensitive to subtle changes in the crystal structure and proton dynamics caused by various thermodynamic conditions. It is established that the kinetics of this transformation can be described using the Avrami model with an effective Avrami index value associated with homogeneous nucleation and three-dimensional growth of a new phase.




copy

X-ray diffraction from strongly bent crystals and spectroscopy of X-ray free-electron laser pulses

The use of strongly bent crystals in spectrometers for pulses of a hard X-ray free-electron laser is explored theoretically. Diffraction is calculated in both dynamical and kinematical theories. It is shown that diffraction can be treated kinematically when the bending radius is small compared with the critical radius given by the ratio of the Bragg-case extinction length for the actual reflection to the Darwin width of this reflection. As a result, the spectral resolution is limited by the crystal thickness, rather than the extinction length, and can become better than the resolution of a planar dynamically diffracting crystal. As an example, it is demonstrated that spectra of the 12 keV pulses can be resolved in the 440 reflection from a 20 µm-thick diamond crystal bent to a radius of 10 cm.




copy

my windows phone is not copying




copy

Issues Copying a Compilation Album to My iPod




copy

The many flavours of halogen bonds – message from experimental electron density and Raman spectroscopy

Experimental electron-density studies based on high-resolution diffraction experiments allow halogen bonds between heavy halogens to be classified. The topological properties of the electron density in Cl⋯Cl contacts vary smoothly as a function of the inter­action distance. The situation is less straightforward for halogen bonds between iodine and small electronegative nucleophiles, such as nitro­gen or oxygen, where the electron density in the bond critical point does not simply increase for shorter distances. The number of successful charge–density studies involving iodine is small, but at least individual examples for three cases have been observed. (a) Very short halogen bonds between electron-rich nucleophiles and heavy halogen atoms resemble three-centre–four-electron bonds, with a rather symmetric heavy halogen and without an appreciable σ hole. (b) For a narrow inter­mediate range of halogen bonds, the asymmetric electronic situation for the heavy halogen with a pronounced σ hole leads to rather low electron density in the (3,−1) critical point of the halogen bond; the properties of this bond critical point cannot fully describe the nature of the associated inter­action. (c) For longer and presumably weaker contacts, the electron density in the halogen bond critical point is only to a minor extent reduced by the presence of the σ hole and hence may be higher than in the aforementioned case. In addition to the electron density and its derived properties, the halogen–carbon bond distance opposite to the σ hole and the Raman frequency for the associated vibration emerge as alternative criteria to gauge the halogen-bond strength. We find exceptionally long C—I distances for tetra­fluoro­diiodo­benzene molecules in cocrystals with short halogen bonds and a significant red shift for their Raman vibrations.




copy

Effects of air pollution on Mediterranean plants could be studied with reflectance spectroscopy

A technique called reflectance spectroscopy is the subject of a new literature review focusing on the use of this tool to study the effects of air pollution on vegetation. In particular, the researchers suggest that the technique could be more widely applied in the Mediterranean region, to study the effects of climate change and air pollution, which will be detrimental to crop growth as well as other vegetation. It could also be used as a more general biomonitoring technique for assessing pollutant levels in the environment.




copy

Orangutan copy cats

How smart are copy cats? Maybe it depends on your species




copy

New copyright rules bring busy replica furniture industry in the U.K. to a halt

The era of ersatz Eames chairs and knockoff Noguchi coffee tables comes to an end.



  • Remodeling & Design

copy

Write Website Copy That Sells - Try a Little Flesh with Your Flash

Writing with technology makes sense, but writing for people still makes the sale. Here are two great ways to connect with people across broadband and create copy that sells.




copy

Using Blind Carbon Copy (BCC) For Email Privacy

People expect that you treat their email addresses, personal and other contact details privately. The BCC option provides a sure fire method of not abusing anyones trust and divulging their email address to possible spammers or others to whom it should not be given. This article discusses BCC and it's advantages and disadvantages.




copy

The Cure for Crummy Copy: Laura Belgray of Talking Shrimp on Marketing Smarts [Podcast]

Laura Belgray, founder of Talking Shrimp and co-creator of The Copy Cure, shares tips for writing copy that converts.




copy

VideoSolo DVD Copy New Released – A Simple and High-quality DVD Copy Software

VideoSolo DVD Copy is able to 1:1 copy DVD to a blank DVD disc or copy DVD to hard drive as ISO/folder. For someone who wants to make DVD backups, it may be worth looking at.




copy

SonoPath Announces Copyright and Trademark of SDEP® Ultrasound Protocol

SonoPath LLC announced the copyright and trademark approval of their popular SDEP® veterinary ultrasound training techniques: Sonographic Diagnostic Efficiency Protocol (SDEP) Small Animal Abdominal Imaging and Sonographic Diagnostic Efficiency




copy

Enago Launches AuthorONE - An AI-powered Manuscript Assessment and Automated Copy-editing Solution for Publishers

Unlike other solutions, AuthorONE delivers explainable, actionable results.




copy

What Copycats Know About Innovation

Oded Shenkar, professor at Ohio State University's Fisher College of Business and author of "Copycats."




copy

Newport Man Pleads Guilty to Copyright Infringement for Creating Illegal Video Streaming and Downloading Websites




copy

We rate Aldi's copycat Magnum and Cornetto ice creams and Twister lollies

Laura Nightingale tested out seven of Aldi's icy desserts to see how they stacked up against the big brands




copy

GoCopy – The Best Adobe InDesign Collaboration Tool

GoCopy is the simplest way for copywriters and designers to collaborate better on Adobe InDesign content. Get your copy free!




copy

Fluorescent nanoscopy device and method

A method for analysis of an object dyed with fluorescent coloring agents. Separately fluorescing visible molecules or nanoparticles are periodically formed in different object parts, the laser produces the oscillation thereof which is sufficient for recording the non-overlapping images of the molecules or nanoparticles and for decoloring already recorded fluorescent molecules, wherein tens of thousands of pictures of recorded individual molecule or nanoparticle images, in the form of stains having a diameter on the order of a fluorescent light wavelength multiplied by a microscope amplification, are processed by a computer for searching the coordinates of the stain centers and building the object image according to millions of calculated stain center co-ordinates corresponding to the co-ordinates of the individual fluorescent molecules or nanoparticles. Two-dimensional and three-dimensional images are provided for proteins, nucleic acids and lipids with different coloring agents.




copy

Cable-free arthroscopy

The present invention relates to an arthroscopy apparatus, comprising at least three elements selected from: a conventional arthroscopic lens (12), to which there is coupled a power supply device or capsule, in the inside of which is the power source (1), and a miniature camera (8), characterized by not comprising connecting cables.




copy

Peri-critical reflection spectroscopy devices, systems, and methods

Spectroscopy apparatuses oriented to the critical angle of the sample are described that detecting the spectral characteristics of a sample wherein the apparatus consists of an electromagnetic radiation source adapted to excite a sample with electromagnetic radiation introduced to the sample at a location at an angle of incidence at or near a critical angle of the sample; a transmitting crystal in communication with the electromagnetic radiation source and the sample, the transmitting crystal having a high refractive index adapted to reflect the electromagnetic radiation internally; a reflector adapted to introduce the electromagnetic radiation to the sample at or near an angle of incidence near the critical angle between the transmitting crystal and sample; and a detector for detecting the electromagnetic radiation from the sample. Also, provided herein are methods, systems, and kits incorporating the peri-critical reflection spectroscopy apparatus.




copy

Method for copy protection

A method for copy protection in which an audiovisual or audio data is divided into a plurality of portions. The plurality of portions is at least partly scrambled and prepared so as to be stored on a record carrier in the scrambled order. This is done so that a physical position on the record carrier, e.g., a sector of the record carrier, where a respective portions of the divided data is stored depends on the scrambled order.




copy

Network-based revocation, compliance and keying of copy protection systems

A method of authenticating a device involves establishing a local connection between a local target device and a local source device; at the source device, obtaining credentials of the target device via the local connection; at the source device, sending the credentials to a cloud authentication server via a secure communication channel; at the cloud authentication server, checking the credentials of the target device against a database of known good devices; at the source device, receiving a message from the cloud authentication server via the secure communication channel, said message indicating that the target device is authenticated; and delivering content from the source device to the target device on the condition that the target device is authenticated. This abstract is not to be considered limiting, since other embodiments may deviate from the features described in this abstract.




copy

Sample preparation for spectroscopy analysis

A sample is cleaned up for spectroscopic analysis by receiving a slide substrate having the sample thereon, fixing the sample to a substrate surface of the slide substrate by applying heat to the slide substrate for a predetermined heating time and incubating the sample on the slide substrate for a predetermined incubation time after fixing the sample to the slide substrate. The sample is further cleaned by washing the sample on the slide substrate after the sample has been incubated and drying the sample by applying heat to the slide substrate for a predetermined drying time, wherein the sample on the slide substrate after drying has retained particles of interest and interferant particles are removed from the substrate. A substrate is also provided for sample collection, which is culturable and Raman silent.




copy

Sialendoscopy demonstration apparatus

Models, kits and methods useful in the demonstration of sialendoscopy devices and techniques are described. An exemplary demonstration apparatus comprises a support structure, an insert structure contacting the support structure, and a duct structure contacting the insert structure. The insert structure has a top surface defining a first opening and a bottom surface defining a second opening, and defines a channel with a first end in communication with the first opening and a second end in communication with the second opening. The duct structure comprises an elongate tubular member and has a first end in fluid communication with the first opening of the insert member, a second end, and defines a lumen extending from the first end to the second end. A portion of the duct structure is releasably disposed within the channel defined by the insert structure.




copy

Copying cutting device for wood lathes

A copying cutting device for wood lathes including two securing stems, two form securing devices each transversely mounted at the bottom end of each securing stem, a guide track device mounted above the securing stems, a cutter mounting device having a cutter mounted thereon screwably provided at the bottom side of the guide track device, and a form tracing device screwably disposed at the rear end of the cutter. The forms securing device positions a copy, and a tracing rod of the form tracing device urges against the tracing edge of the copy. The cutter slides in the cutter mounting device, which in turn slides in the guide track device. The cutter cuts the workpiece following the contour of the copy with the help of the tracing rod.




copy

Mixcloud Launches A DJ Live Streaming Platform With Copyright Figured Out

The live streaming scene might feel crowded, but this week Mixcloud has introduced their own endeavor. They’ve launched a streaming platform built specifically for DJs, Mixcloud Live—not only taking on streaming giants like Facebook, Twitch, and Youtube, but also creating much-needed relief for DJ streams that are continually flagged for copyright. The team at Mixcloud […]

The post Mixcloud Launches A DJ Live Streaming Platform With Copyright Figured Out appeared first on DJ TechTools.




copy

Delhi HC restrains Campus from selling shoe range on Puma’s copyright plaint

Campus Activewear is part of the Synergy Action Group that sells 100,000 pairs of shoes every day through more than 50,000, mostly third-party, outlets, according to Action Shoes’ website.