ubs

Snort Subscriber Rules Update 2024-10-24

Posted by Research via Snort-sigs on Oct 24

Talos Snort Subscriber Rules Update

Synopsis:
This release adds and modifies rules in several categories.

Details:
Talos has added and modified multiple rules in the file-multimedia,
malware-cnc, protocol-snmp and server-webapp rule sets to provide
coverage for emerging threats from these technologies.

For a complete list of new and modified rules please see:

https://www.snort.org/advisories




ubs

Snort Subscriber Rules Update 2024-10-29

Posted by Research via Snort-sigs on Oct 29

Talos Snort Subscriber Rules Update

Synopsis:
This release adds and modifies rules in several categories.

Details:
Talos has added and modified multiple rules in the browser-firefox,
malware-cnc, malware-other, os-linux and server-webapp rule sets to
provide coverage for emerging threats from these technologies.

For a complete list of new and modified rules please see:

https://www.snort.org/advisories




ubs

Snort Subscriber Rules Update 2024-10-31

Posted by Research via Snort-sigs on Oct 31

Talos Snort Subscriber Rules Update

Synopsis:
This release adds and modifies rules in several categories.

Details:
Talos has added and modified multiple rules in the malware-cnc,
malware-other and server-other rule sets to provide coverage for
emerging threats from these technologies.

For a complete list of new and modified rules please see:

https://www.snort.org/advisories




ubs

Snort Subscriber Rules Update 2024-11-04

Posted by Research via Snort-sigs on Nov 04

Talos Snort Subscriber Rules Update

Synopsis:
This release adds and modifies rules in several categories.

Details:
Talos has added and modified multiple rules in the and server-webapp
rule sets to provide coverage for emerging threats from these
technologies.

For a complete list of new and modified rules please see:

https://www.snort.org/advisories




ubs

Snort Subscriber Rules Update 2024-11-07

Posted by Research via Snort-sigs on Nov 07

Talos Snort Subscriber Rules Update

Synopsis:
This release adds and modifies rules in several categories.

Details:
Talos has added and modified multiple rules in the browser-plugins and
server-webapp rule sets to provide coverage for emerging threats from
these technologies.

For a complete list of new and modified rules please see:

https://www.snort.org/advisories




ubs

Snort Subscriber Rules Update 2024-11-12

Posted by Research via Snort-sigs on Nov 12

Talos Snort Subscriber Rules Update

Synopsis:
Talos is aware of vulnerabilities affecting products from Microsoft
Corporation.

Details:
Microsoft Vulnerability CVE-2024-43451:
A coding deficiency exists in Microsoft Windows SmartScreen that may
lead to spoofing.

Rules to detect attacks targeting these vulnerabilities are included in
this release and are identified with:
Snort 2: GID 1, SIDs 62022 through 62023,
Snort 3: GID 1, SID 300612....




ubs

Could Subscription-Based Heat Pumps Be the Future of Electrification?

Scandinavian green energy startup Aira plans to offer a 10-year service guarantee and a monthly fee that includes installation, maintenance.




ubs

Schematics and docs needed for communication systems of substation protective relaying system

Communication systems of electric utilities have become increasingly critical to electric system protection, operation, and maintenance. For fast tripping and clearing of system faults, communication-aided relaying has become a common protection scheme, particularly in line protection. Control centers depend on... Read more

The post Schematics and docs needed for communication systems of substation protective relaying system appeared first on EEP - Electrical Engineering Portal.




ubs

The problem of induced voltages in control cables in high voltage substations

Cabling in power substations is very important due to the fact that they are the longest parts of a system and therefore act as efficient antennas that pickup and or radiate noise. In HV substations, there are different kinds of conductors... Read more

The post The problem of induced voltages in control cables in high voltage substations appeared first on EEP - Electrical Engineering Portal.




ubs

The essential HV/EHV substation auxiliary facilities you should know about

Nowadays, HV/EHV substations have become pretty complex from the design point of view. Besides the main electrical equipment, which must be designed and selected correctly, there are several auxiliary facilities without which a substation would not be able to operate... Read more

The post The essential HV/EHV substation auxiliary facilities you should know about appeared first on EEP - Electrical Engineering Portal.




ubs

Design issues in HV busbar protection systems (substation topology and DC power supply)

This technical article discusses criteria and requirements for designing protection systems for busbars in HV/EHV networks. One of the most critical requirements is reliable busbar relay protection to assure power system integrity during fault conditions. This requirement is further emphasized because... Read more

The post Design issues in HV busbar protection systems (substation topology and DC power supply) appeared first on EEP - Electrical Engineering Portal.




ubs

Tricks in designing and analyzing schematics and diagrams of high voltage substations

High voltage power substations are complex networks of power and control connections, represented by design elements like- Single Line Diagrams, layout and block diagrams, schematics, logic diagrams, schedules, and so many more. Wiring diagrams and schematics, in a sense, are... Read more

The post Tricks in designing and analyzing schematics and diagrams of high voltage substations appeared first on EEP - Electrical Engineering Portal.




ubs

Good practice in the design of concrete and steel structures in power substations

The process of designing a substation usually begins with the general substation layout, which is dependent on the required safety clearance and insulation withstand, as well as the permissible loads delivered to substation equipment and structures. The permissible loads, in... Read more

The post Good practice in the design of concrete and steel structures in power substations appeared first on EEP - Electrical Engineering Portal.




ubs

Secondary equipment you should always consider when retrofitting existing HV substation

This approach assumes retrofitting and upgrading old substation secondary equipment such as intelligent electronic devices (IEDs), monitoring sensors, power apparatus, communication protocol and operating standards to improve the overall performance or reduce cost without disrupting the continuity of service. For... Read more

The post Secondary equipment you should always consider when retrofitting existing HV substation appeared first on EEP - Electrical Engineering Portal.




ubs

The true art of control, monitoring and protection provided by Substation Automation Systems

The Substation Automation Systems, often known as SASs, are responsible for a tremendous variety of tasks. These include some extremely important actions, such as clearing faults in a timely manner in order to maintain the physical condition of power system... Read more

The post The true art of control, monitoring and protection provided by Substation Automation Systems appeared first on EEP - Electrical Engineering Portal.




ubs

ATS Schematics and Logic Analysis for a Substation 415V AC Auxiliary Supply Panel

In modern electrical power systems, ensuring a reliable and continuous supply of electricity is critical, particularly in facilities where downtime can result in significant operational disruptions and financial losses. Low voltage automatic transfer schemes at substations play a vital role... Read more

The post ATS Schematics and Logic Analysis for a Substation 415V AC Auxiliary Supply Panel appeared first on EEP - Electrical Engineering Portal.




ubs

Best practice in hard times: How to safeguard the hundreds and thousands of substations

Like it or not, hard times are in front of us, by all means. I won’t deal the hard times now, but instead, I’ll shortly say that it’s all about the energy resources and who owns them. It’s also not... Read more

The post Best practice in hard times: How to safeguard the hundreds and thousands of substations appeared first on EEP - Electrical Engineering Portal.




ubs

How (should) power utilities handle grid failures by utilizing mobile substations

Every nation has numerous vital facilities that are largely dependent on electricity to function. Infrastructures that are critical to a quick response to outages include the public health system, the communications sector, and government services like emergency first responders. Nonetheless,... Read more

The post How (should) power utilities handle grid failures by utilizing mobile substations appeared first on EEP - Electrical Engineering Portal.




ubs

Mechanical Check, Visual Inspection and Electrical Test of the Substation Grounding System (1)

Substation earthing, or grounding, is essential for electrical safety and reliability in substations, which are critical nodes in the power distribution network. Proper earthing ensures safe dissipation of fault currents into the ground, preventing dangerous voltage build-ups that could cause... Read more

The post Mechanical Check, Visual Inspection and Electrical Test of the Substation Grounding System (1) appeared first on EEP - Electrical Engineering Portal.




ubs

Energy metering in LV/MV substations and utilities: Dos and don’ts in installation and operation

Energy meters are one of the most important components for monitoring and data acquisition in a power system network with roles in every part of the power system network, from the generation to the commercialized end-users, through multiple transmission and... Read more

The post Energy metering in LV/MV substations and utilities: Dos and don’ts in installation and operation appeared first on EEP - Electrical Engineering Portal.




ubs

A quick reminder to substation transformer basics and safety precautions, dos and don’ts

Let us remind ourselves of the basics of substation transformer parts, their operation principles, and do’s and don’ts for safety measures and precautions. For novice substation engineers it’s important to recognize every single detail of a transformer and later to... Read more

The post A quick reminder to substation transformer basics and safety precautions, dos and don’ts appeared first on EEP - Electrical Engineering Portal.




ubs

Mechanical Check, Visual Inspection and Electrical Test of the Substation Grounding System (2)

At the beginning of my career in 2005, I had the opportunity to work at a 500kV substation with the National Transmission and Dispatch Company in Pakistan. During this time, I was introduced to various tools and techniques that were... Read more

The post Mechanical Check, Visual Inspection and Electrical Test of the Substation Grounding System (2) appeared first on EEP - Electrical Engineering Portal.




ubs

Choosing between AIS and GIS substation design: Factors you MUST take into consideration

For the last sixty years, gas-insulated substation (GIS) has been used in applications related to substations all over the world, and this use of the technology is becoming an increasingly common asset for those who make use of substations. GIS... Read more

The post Choosing between AIS and GIS substation design: Factors you MUST take into consideration appeared first on EEP - Electrical Engineering Portal.




ubs

A detailed checklist for the installation and commissioning of Gas-Insulated Substations (GIS)

Gas-insulated substations (GIS) are critical components of modern electrical power systems, providing efficient and compact solutions for the transmission and distribution of electricity. These substations utilize sulfur hexafluoride (SF6) gas as an insulating and arc-quenching medium, offering several advantages over... Read more

The post A detailed checklist for the installation and commissioning of Gas-Insulated Substations (GIS) appeared first on EEP - Electrical Engineering Portal.




ubs

Substation Equipment Maintenance: Often Neglected Until Something Big Drops Dead

The aging process starts the moment new substation equipment is put into service; how quickly it happens depends on a number of factors, including the equipment’s use, the environment, the quality of maintenance, and many more. However, things aren’t the... Read more

The post Substation Equipment Maintenance: Often Neglected Until Something Big Drops Dead appeared first on EEP - Electrical Engineering Portal.




ubs

Bringing new life to an old Air-Insulated Substation (AIS)

An increasing number of substations globally are aging, while the construction of new ones is hindered by competitive limitations, rigorous environmental rules, and community acceptance issues. Simultaneously, the demand for electricity is consistently escalating, resulting in increased short circuit levels... Read more

The post Bringing new life to an old Air-Insulated Substation (AIS) appeared first on EEP - Electrical Engineering Portal.




ubs

Eight substation equipment needed to power up data center

A few years ago I participated in an interesting project Telenor Data Center in Belgrade – The most advanced technical building in the region of Central and Eastern Europe. The building extends to 2,600 square meters and has the most... Read more

The post Eight substation equipment needed to power up data center appeared first on EEP - Electrical Engineering Portal.




ubs

LV/MV power substation equipment and wiring requirements you must understand

The space requirements of a power substation depend on the equipment to be housed, and on whether a new building can be erected for it or it has to be fitted into an existing building. In the case of an... Read more

The post LV/MV power substation equipment and wiring requirements you must understand appeared first on EEP - Electrical Engineering Portal.




ubs

Thoughtful considerations to design MV/LV distribution substations for extended service life

The installation of a new MV/LV electrical substation is often part of a more global project, and it is not always the subject of very detailed attention. However, the consideration of simple and practical criteria is not always dictated by... Read more

The post Thoughtful considerations to design MV/LV distribution substations for extended service life appeared first on EEP - Electrical Engineering Portal.




ubs

Capacitor banks in substations: Schemes, relay settings, and protective measures

Let’s discuss capacitor banks, but this time, not the basics. Let’s study the double-star capacitor bank configuration and protective techniques used in the substations. How important is to choose the right current transformer ratio, calculate rated and maximum overload currents,... Read more

The post Capacitor banks in substations: Schemes, relay settings, and protective measures appeared first on EEP - Electrical Engineering Portal.




ubs

Modern practice for LV/MV substation and power distribution systems within buildings

In the present era, the presence of reliable and uninterrupted electricity is commonly assumed in the majority of nations. Nevertheless, in many nations, this is susceptible to frequent disruptions caused by a range of issues, including as insufficient supply, inefficient... Read more

The post Modern practice for LV/MV substation and power distribution systems within buildings appeared first on EEP - Electrical Engineering Portal.




ubs

Vulnerable carbon stores twice as high where permafrost subsidence is factored in, new research finds

Sinking terrain caused by the loss of ice and soil mass in permafrost is causing deeper thaw than previously thought and making vulnerable twice as much carbon as estimates that don’t account for this shifting ground.

The post Vulnerable carbon stores twice as high where permafrost subsidence is factored in, new research finds appeared first on GeoSpace.




ubs

Coca-Cola Company's New Subscription Service Sells Out in 3 Hours

The Coca-Cola Company announced the launch of The Coca-Cola Insiders Club, a subscription service offering a limited number of people the chance to taste over 20 of the company’s new beverages set to launch early next year.




ubs

Molded Fiber Labeling for round fiber molded tubs to premiere at interpack

A glue-free label solution, Molded Fiber Labeling involves 100% mono-material packaging that can be fully recycled or composted.




ubs

Quadpack and PSB Industries subsidiary Texen to combine into a single group

The new group will be positioned among the Top 5 cosmetics packaging companies worldwide, boasting combined sales of around €350 million.




ubs

Crespel & Deiters Group opens corrugating subsidiary in Mexico

Leading European wheat adhesive specialist improves service for corrugated board manufacturers in Latin America.





ubs

Japan government reportedly mulls continuing electricity, gas price subsidies next year

For some context, these subsidies did come to an end in May but were reinstated in August through to October to cope with the warmer weather. Subsequently, they were continued until this year-end but the funds had to be drawn from reserves in the budget for the fiscal year that started in April.

NHK is now reporting that the government is considering keeping these subsidies from January through to March next year. Amid a higher cost of living in key populated areas such as Tokyo, the measure above is mainly to try and combat rising consumer prices.

This article was written by Justin Low at www.forexlive.com.




ubs

Regulation (EU) 2024/1938 of the European Parliament and of the Council of 13 June 2024 on Standards of Quality and Safety for Substances of Human Origin Intended for Human Application and Repealing Directives 2002/98/EC and 2004/23/EC

Room 21, Parliament Buildings



  • Windsor Framework Democratic Scrutiny Committee

ubs

Regulation (EU) 2024/1938 on Standards of Quality and Safety for Substances of Human Origin intended for Human Application

Room 21, Parliament Buildings



  • Windsor Framework Democratic Scrutiny Committee

ubs

Banking Hubs in Northern Ireland: Cash Access UK

Room 21, Parliament Buildings



  • Committee for Finance

ubs

COM(2022)748 Proposal for a Regulation Amending Regulation (EC) 1272/2008 on Classification, Labelling and Packaging of Substances and Mixtures: Department for the Economy; Department of Health; Department of Justice

Room 30, Parliament Buildings



  • Windsor Framework Democratic Scrutiny Committee

ubs

Chicago Cubs Reach Settlement Over Alleged ADA Violations




ubs

Biden’s Green Energy Subsidies Are Making China Great Again – Using Biden-Harris IRA law to ‘expand their solar dominance’

Biden’s Green Energy Subsidies Are Making China Great Again The left-wing site Politico was surprisingly honest with this headline: Biden is desperately trying to lure solar panel production from China to the United States with lavish subsidies. But the companies that are taking the cash and hanging a shingle are… Chinese: When Biden and congressional Democrats passed the […]




ubs

Arraez, Marlins break tie in eighth inning, sweep Cubs to move to 10-0 in one-run games

Marlins returned to a season-best three games over .500 as Luis Arraez, who drove in two runs, logged at least one hit for the 25th time in the season's 29 games.




ubs

[ E.212 (09/16) ] - The international identification plan for public networks and subscriptions

The international identification plan for public networks and subscriptions




ubs

TR.FSR - Factual subscriber-base reporting and protected content delivery in a conditional access system (CAS)

TR.FSR - Factual subscriber-base reporting and protected content delivery in a conditional access system (CAS)




ubs

Operational Bulletin No. 1280 (15.XI.2023) and Annexed List: <br/> Mobile Network Codes (MNC) for the international identification plan for public networks and subscriptions (According to Recommendation ITU-T E.212 (09/2016)) (Position on 15 Novemb

Operational Bulletin No. 1280 (15.XI.2023) and Annexed List:
Mobile Network Codes (MNC) for the international identification plan for public networks and subscriptions (According to Recommendation ITU-T E.212 (09/2016)) (Position on 15 November 2023)




ubs

Mobile Network Codes (MNC) for the international identification plan for public networks and subscriptions (According to Recommendation ITU-T E.212 (09/2016))

Mobile Network Codes (MNC) for the international identification plan for public networks and subscriptions (According to Recommendation ITU-T E.212 (09/2016))




ubs

[ Q.4014.2 (04/19) ] - PSTN/ISDN terminal equipment using IP multimedia core network subsystem; Conformance testing - Part 2: Test suite structure and test purposes

PSTN/ISDN terminal equipment using IP multimedia core network subsystem; Conformance testing - Part 2: Test suite structure and test purposes