io

Imaging P-glycoprotein Induction at the Blood-Brain Barrier of a Beta-Amyloidosis Mouse Model with 11C-Metoclopramide PET

P-glycoprotein (ABCB1) plays an important role at the blood-brain barrier (BBB) in promoting the clearance of neurotoxic beta-amyloid (Aß) peptides from the brain into the blood. ABCB1 expression and activity were found to be decreased in the brains of Alzheimer disease (AD) patients. Treatment with drugs which induce cerebral ABCB1 activity may be a promising approach to delay the build-up of Aß deposits in the brain by enhancing the clearance of Aß peptides from the brain. The aim of this study was to investigate whether PET with the weak ABCB1 substrate radiotracer 11C-metoclopramide can measure ABCB1 induction at the BBB in a beta-amyloidosis mouse model (APP/PS1-21 mice) and in wild-type mice. Methods: Groups of wild-type and APP/PS1-21 mice aged 50 or 170 days underwent 11C-metoclopramide baseline PET scans or scans after intraperitoneal treatment with the rodent pregnane X receptor (PXR) activator 5-pregnen-3β-ol-20-one-16α-carbonitrile (PCN, 25 mg/kg) or its vehicle over 7 days. At the end of the PET scans, brains were harvested for immunohistochemical analysis of ABCB1 and Aß levels. In separate groups of mice, radiolabeled metabolites of 11C-metoclopramide were determined in plasma and brain at 15 min after radiotracer injection. As an outcome parameter of cerebral ABCB1 activity, the elimination slope of radioactivity washout from the brain (kE,brain) was calculated. Results: PCN treatment resulted in an increased clearance of radioactivity from the brain as reflected by significant increases in kE,brain (from +26% to +54% relative to baseline). Immunohistochemical analysis confirmed ABCB1 induction in the brains of PCN-treated APP/PS1-21 mice with a concomitant decrease in Aß levels. There was a significant positive correlation between kE,brain values and ABCB1 levels in the brain. In wild-type mice, a significant age-related decrease in kE,brain values was found. Metabolite analysis showed that the majority of radioactivity in the brain was composed of unmetabolized 11C-metoclopramide in all animal groups. Conclusion: 11C-metoclopramide can measure ABCB1 induction in the mouse brain without the need to consider an arterial input function and may find potential application in AD patients to non-invasively evaluate strategies to enhance the clearance properties of the BBB.




io

18F-Fluorodeoxyglucose Positron Emission Tomography / Computed Tomography in Left-Ventricular Assist Device Infection: Initial Results Supporting the Usefulness of Image-Guided Therapy

Background: Accurate definition of the extent and severity of left-ventricular assist device (LVAD) infection may facilitate therapeutic decision making and targeted surgical intervention. Here, we explore the value of 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for guidance of patient management. Methods: Fifty-seven LVAD-carrying patients received 85 whole-body 18F-FDG PET/CT scans for the work-up of device infection. Clinical follow-up was obtained over a period of up to two years. Results: PET/CT showed various patterns of infectious involvement of the 4 LVAD components: driveline entry point (77% of cases), subcutaneous driveline path (87%), pump pocket (49%) and outflow tract (58%). Driveline smears revealed staphylococcus or pseudomonas strains as the underlying pathogen in a majority of cases (48 and 34%, respectively). At receiver-operating characteristics analysis, an 18F-FDG standardized uptake value (SUV) >2.5 was most accurate to identify smear-positive driveline infection. Infection of 3 or all 4 LVAD components showed a trend towards lower survival vs infection of 2 or less components (P = 0.089), while involvement of thoracic lymph nodes was significantly associated with adverse outcome (P = 0.001 for nodal SUV above vs below median). Finally, patients that underwent early surgical revision within 3 months after PET/CT (n = 21) required significantly less inpatient hospital care during follow-up when compared to those receiving delayed surgical revision (n = 11; p<0.05). Conclusion: Whole-body 18F-FDG PET/CT identifies the extent of LVAD infection and predicts adverse outcome. Initial experience suggests that early image-guided surgical intervention may facilitate a less complicated subsequent course.




io

18F-fluorodexyglucose Position Emission Tomography identifies altered brain metabolism in patients with Cri du Chat syndrome

Cri-Du-Chat Syndrome (CdCs) is a rare genetic disease caused by a deletion in the short arm of chromosome 5 (5p) with a variable clinical spectrum. To date no study in literature has ever investigated the alterations of brain glucose metabolism in these subjects by means of [18F]fluoro-2-deoxy-d-glucose Positron Emission Tomography/Computed Tomography (18F-FDG PET/CT). The aims of this study were to detect difference in brain FDG metabolism in patients affected by CdCs with different clinical presentations and identify possible "brain metabolic phenotypes" of this syndrome. Methods: 6 patients (age: 5 M and 1 F, age range: 10-27) with CdCs were assessed for presence of cognitive and behavioral symptoms with a battery of neuropsychological tests and then classified as patient with a severe or mild phenotype. Then, patients underwent a brain 18F-FDG PET/CT scan. PET/CT findings were compared to a control group, matched for age and sex, by using statistical parametric mapping (SPM). Association of different clinical phenotypes and 18F-FDG PET/CT findings was investigated. Results: Four patients presented a severe phenotype, whereas 2 patients demonstrated mild phenotype. SPM single subject and group analysis compared to the control cohort revealed a significant hypometabolism in the left temporal lobe (BAs 20, 36 and 38), in the right frontal subcallosal gyrus (BA 34) and caudate body, and in the cerebellar tonsils (p<0.001). Hypermetabolism (P = 0.001) was revealed in the right superior and precentral frontal gyrus (BA 6) in patient group compared to the control cohort. In SPM single subject analysis the hypermetabolic areas were detected only in patients with a severe phenotype. Conclusion: This study revealed different patterns of brain glucose metabolism in patients with severe and mild phenotype compared to control subjects. In particular, the hypermetabolic abnormalities in the brain, evaluated by18F-FDG PET/CT, seem to correlate with the severe phenotype in patients with CdCs.




io

Radiation dosimetry and biodistribution of 68Ga-FAPI-46 PET imaging in cancer patients

Background: Targeting cancer-associated fibroblasts (CAFs) has become an attractive goal for diagnostic imaging and therapy as they can constitute as much as 90% of tumor mass. The serine protease fibroblast activation protein (FAP) is overexpressed selectively in CAFs, drawing interest in FAP as a stromal target. The quinoline-based FAP-inhibitor PET tracer, 68Ga-FAPI-04, has been previously shown to yield high tumor-to-background ratios (TBR) in patients with various cancers. Recent developments towards an improved compound for therapeutic application have identified FAPI-46 as a promising agent due to a longer tumor retention time in comparison with FAPI-04. Here we present a PET biodistribution and radiation dosimetry study of 68Ga-FAPI-46 in cancer patients. Methods: Six patients with different cancers underwent serial 68Ga-FAPI-46 PET/CT scans at three time points following radiotracer injection: 10 minutes, 1 hour, and 3 hours. The source organs consisted of the kidneys, bladder, liver, heart, spleen, bone marrow, uterus, and body remainder. OLINDA/EXM v.1.1 software was used to fit and integrate the kinetic organ activity data to yield total body and organ time-integrated activity coefficients/residence times and finally organ absorbed doses. Standardized uptake values (SUV) and TBR were generated from the contoured tumor and source organ volumes. Spherical volumes in muscle and blood pool were also obtained for TBR (Tumor SUVmax / Organ SUVmean). Results: At all timepoints, the highest organ SUVmax was observed in the liver. Tumor and organ mean SUVs decreased whereas TBRs in all organs but the uterus increased with time. The highest TBRs at 3 hours were observed with the bone marrow (31.1), muscle (22.8), heart (19.1), and spleen (19.0). Organs with the highest effective doses were the bladder wall (2.41E-03 mSv/MBq), followed by ovaries (1.15E-03 mSv/MBq) and red marrow (8.49E-04mSv/MBq). The average effective total body dose was 7.80E-03 mSv/MBq. Thus for administration of 200 MBq 68Ga-FAPI-46 the effective total body dose is 1.56 mSv ± 0.26 mSv, in addition to approximately 3.7 mSv from one low-dose CT scan done for attenuation correction. Conclusion: 68Ga-FAPI-46 PET/CT has a favorable dosimetry profile with an estimated whole body dose of 5.3 mSv for an administration of 200 MBq (5.4 mCi) of 68Ga-FAPI-46 (1.56± 0.26 mSv from the PET tracer and 3.7 mSv from one low-dose CT scan). The biodistribution study showed high TBRs increasing over time, suggesting high diagnostic performance and favorable tracer kinetics for potential therapeutic applications.




io

Does 2-FDG-PET Accurately Reflect Quantitative In vivo Glucose Utilization?

2-Deoxy-2-[18F]fluoro-D-glucose (2-FDG) with positron emission tomography (2-FDG-PET) is undeniably useful in the clinic, among other uses, to monitor change over time using the 2-FDG standardized uptake values (SUV) metric. This report suggests some potentially serious caveats for this and related roles for 2-FDG PET. Most critical is the assumption that there is an exact proportionality between glucose metabolism and 2-FDG metabolism, called the lumped constant, LC. This report describes that LC is not constant for a specific tissue and may be variable before and after disease treatment. The purpose of this work is not to deny the clinical value of 2-FDG PET; it is a reminder that when one extends the use of an appropriately qualified imaging method, new observations may arise and further validation would be necessary. Current understanding of glucose-based energetics in vivo is based on the quantification of glucose metabolic rates with 2-FDG PET, a method that permits the non-invasive assessment in various human disorders. However, 2-FDG is only a good substrate for facilitated-glucose transporters (GLUTs) but not for sodium-dependent glucose co-transporters (SGLTs), which have recently been shown to be distributed in multiple human tissues. Thus, the GLUT-mediated in vivo glucose utilization measured by 2-FDG PET would be blinded to the potentially substantial role of functional SGLTs in glucose transport and utilization. Therefore, in these circumstances the 2-FDG LC used to quantify in vivo glucose utilization should not be expected to remain constant. 2-FDG LC variations have been especially significant in tumors, particularly at different stages of cancer development, affecting the accuracy of quantitative glucose measures and potentially limiting the prognostic value of 2-FDG, as well as its accuracy in monitoring treatments. SGLT-mediated glucose transport can be estimated using α-methyl-4-deoxy-4-[18F]fluoro-D-glucopyranoside (Me-4FDG). Utilizing both 2-FDG and Me-4FDG should provide a more complete picture of glucose utilization via both GLUT and SGLT transporters in health and disease stages. Given the widespread use of 2-FDG PET to infer glucose metabolism, appreciating the potential limitations of 2-FDG as a surrogate for glucose metabolic rate and the potential reasons for variability in LC is relevant. Even when the readout for the 2-FDG PET study is only an SUV parameter, variability in LC is important, particularly if it changes over the course of disease progression (e.g., an evolving tumor).




io

What You See Is Not What You Get - On the Accuracy of Voxel-Based Dosimetry in Molecular Radiotherapy

Due to improvements in quantitative SPECT/CT, voxel-based dosimetry for radionuclide therapies has aroused growing interest as it promises the visualization of absorbed doses at a voxel level. In this work, SPECT/CT-based voxel-based dosimetry of a 3D printed 2-compartment kidney phantom was performed, and the resulting absorbed dose distributions were examined. Additionally, the potential of the PETPVC partial-volume correction tool was investigated. Methods: Both kidney compartments (70% cortex, 30% medulla) were filled with different activity concentrations and SPECT/CT imaging was performed. The images were reconstructed using varying reconstruction settings (iterations, subsets, and post-filtering). Based on these activity concentration maps, absorbed dose distributions were calculated with pre-calculated 177Lu voxel S values and an empirical kidney half-life. An additional set of absorbed doses was calculated after applying PETPVC for partial-volume correction of the SPECT reconstructions. Results: SPECT/CT imaging blurs the two discrete sub-organ absorbed dose values into a continuous distribution. While this effect is slightly improved by applying more iterations, it is enhanced by additional post-filtering. By applying PETPVC, the absorbed dose values are separated into 2 peaks. Although this leads to a better agreement between SPECT/CT-based and nominal values, considerable discrepancies remain. In contrast to the calculated nominal absorbed doses of 7.8/1.6 Gy (cortex/medulla), SPECT/CT-based voxel-level dosimetry resulted in mean absorbed doses ranging from 3.0-6.6 Gy (cortex) and 2.7-5.1 Gy (medulla). PETPVC led to improved ranges of 6.1-8.9 Gy (cortex) and 2.1-5.4 Gy (medulla). Conclusion: Our study shows that 177Lu quantitative SPECT/CT imaging leads to voxel-based dose distributions largely differing from the real organ distribution. SPECT/CT imaging and reconstruction deficiencies might directly translate into unrealistic absorbed dose distributions, thus questioning the reliability of SPECT-based voxel-level dosimetry. Therefore, SPECT/CT reconstructions should be adapted to ensure an accurate quantification of the underlying activity and, therefore, absorbed dose in a volume-of-interest of the expected object size (e.g. organs, organ sub-structures, lesions or voxels). As an example, PETPVC largely improves the match between SPECT/CT-based and nominal dose distributions. In conclusion, the concept of voxel-based dosimetry should be treated with caution. Specifically, it should be kept in mind that the absorbed dose distribution is mainly a convolved version of the underlying SPECT reconstruction.




io

Quantitative 3D assessment of 68Ga-DOTATOC PET/MRI with diffusion-weighted imaging to assess imaging markers for gastroendopancreatic neuroendocrine tumors: Preliminary results

68Ga-DOTATOC-PET/MRI (68Gallium-DOTATOC-positron emission tomography/magnetic resonance imaging) combines the advantages of PET in the acquisition of metabolic-functional information with the high soft tissue contrast of MRI. Standardized uptake values (SUV) in tumors were suggested as a measure of somatostatin receptor expression. A challenge with receptor ligands is, that the distribution volume is confined to tissues with tracer-uptake, potentially limiting SUV quantification. In this study, different functional, three-dimensional (3D) SUV, apparent diffusion coefficient (ADC) parameters and arterial tumor enhancement were tested for the characterization of gastroendopancreatic neuroendocrine tumors (GEP-NET). Methods: For this single-center, cross-sectional study, 22 patients with 24 histologically confirmed GEP-NET lesions (15 men/7 women; median, 61 years, range, 43-81 years), who received hybrid 68Ga-DOTA-PET/MRI examinations at 3T between January 2017 and July 2019 met eligibility criteria. SUVs, tumor-to-background ratios (TBR), the total functional tumor volume (TFTV), ADCmean and ADCmin were measured based on volumes of interest (VOI) and examined with receiver operating characteristic analysis to determine cut-off values for differentiation between low and intermediate grade GEP-NET. Spearman’s rank correlation coefficients were used to assess correlations between functional imaging parameters. Results: The ratio of PET-derived SUVmean and diffusion-weighted imaging (DWI)-derived ADCmin was introduced as a combined variable to predict tumor grade, outperforming single predictors. Based on a threshold ratio of 0.03 to be exceeded, tumors could be classified as grade 2 with a sensitivity of 86% and specificity of 100%. SUV and functional ADC values as well as arterial contrast enhancement parameters showed non-significant and mostly negligible correlations. Conclusion: As receptor density and tumor cellularity appear to be independent, potentially complementary phenomena, the combined PET/MRI ratio SUVmean/ADCmin may be used as a novel biomarker, allowing to differentiate between grade 1 and 2 GEP-NET.




io

Early Detection in a Mouse Model of Pancreatic Cancer by Imaging DNA Damage Response Signalling

Rationale: Despite its widespread use in oncology, the PET radiotracer 18F-FDG is ineffective for improving early detection of pancreatic ductal adenocarcinoma (PDAC). An alternative strategy for early detection of pancreatic cancer involves visualisation of high-grade pancreatic intraepithelial neoplasias (PanIN-3), generally regarded as the non-invasive precursors of PDAC. The DNA damage response is known to be hyper-activated in late-stage PanINs. Therefore, we investigated whether the SPECT imaging agent, 111In-anti-H2AX-TAT, allows visualisation of the DNA damage repair marker H2AX in PanIN-3s in an engineered mouse model of PDAC, to facilitate early detection of PDAC. Methods: Genetically engineered KPC mice (KRasLSL.G12D/+; p53LSL.R172H/+; PdxCre) were imaged with 18F-FDG and 111In-anti-H2AX-TAT. PanIN/PDAC presence visualised by histology was compared with autoradiography and immunofluorescence. Separately, the survival of KPC mice imaged with 111In-anti-H2AX-TAT was evaluated. Results: In KPC mouse pancreata, H2AX expression was increased in high-grade PanINs, but not in PDAC, corroborating earlier results obtained from human pancreas sections. Uptake of 111In-anti-H2AX-TAT, but not 111In-IgG-TAT or 18F-FDG, within the pancreas was positively correlated with the age of KPC mice, which was correlated with the number of high-grade PanINs. 111In-anti-H2AX-TAT localises preferentially in high-grade PanIN lesions, but not in established PDAC. Younger, non-tumour-bearing KPC mice that show uptake of 111In-anti-H2AX-TAT in the pancreas survive significantly shorter than mice with physiological 111In-anti-H2AX-TAT uptake. Conclusion: 111In-anti-H2AX-TAT imaging allows non-invasive detection of DNA damage repair signalling upregulation in pre-invasive PanIN lesions and is a promising new tool to aid in the early detection and staging of pancreatic cancer.




io

Head to head prospective comparison of quantitative lung scintigraphy and segment counting in predicting pulmonary function of lung cancer patients undergoing video-assisted thoracoscopic lobectomy

Prediction of post-operative pulmonary function in lung cancer patients before tumor resection is essential for patient selection for surgery and is conventionally done with a non-imaging segment counting method (SC) or a two-dimensional planar lung perfusion scintigraphy (PS). The purpose of this study was to compare quantitative analysis of PS to single photon emission computed tomography/computed tomography (SPECT/CT) and to estimate the accuracy of SC, PS and SPECT/CT in predicting post-operative pulmonary function in patients undergoing lobectomy. Methods: Seventy-five non-small cell lung cancer (NSCLC) patients planned for lobectomy were prospectively enrolled (68% males, average age 68.1±8 years ). All patients completed pre-operative forced expiratory volume capacity (FEV1), diffusing capacity of the lung for carbon monoxide (DLCO), Tc99m-MAA lung perfusion scintigraphy with PS and SPECT/CT quantification. A subgroup of 60 patients underwent video-assisted thoracoscopic (VATS) lobectomy and measurement of post-operative FEV1 and DLCO. Relative uptake of the lung lobes estimated by PS and SPECT/CT were compared. Predicted post-operative FEV1 and DLCO were derived from SC, PS and SPECT/CT. Prediction results were compared between the different methods and the true post-operative measurements in patients who underwent lobectomy. Results: Relative uptake measurements differed significantly between PS and SPECT/CT in right lung lobes, with a mean difference of -8.2±3.8, 18.0±5.0 and -11.5±6.1 for right upper, middle and lower lobes respectively (p<0.001). The differences between the methods in the left lung lobes were minor with a mean difference of -0.4±4.4 (p>0.05) and -2.0±4.0 (p<0.001) for left upper and lower lobes respectively. No significant difference and strong correlation (R=0.6-0.76, p<0.001) were found between predicted post-operative lung function values according to SC, PS, SPECT/CT and the actual post-operative FEV1 and DLCO. Conclusion: Although lobar quantification parameters differed significantly between PS and SPECT/CT, no significant differences were found between the predicted post-operative lung function results derived from these methods and the actual post-operative results. The additional time and effort of SPECT/CT quantification may not have an added value in patient selection for surgery. SPECT/CT may be advantageous in patients planned for right lobectomies but further research is warranted.




io

177Lu-NM600 targeted radionuclide therapy extends survival in syngeneic murine models of triple-negative breast cancer

Triple negative breast cancer (TNBC) remains the most aggressive subtype of breast cancer leading to the worst prognosis. Because current therapeutic approaches lack efficacy, there is a clinically unmet need for effective treatment alternatives. Herein, we demonstrate a promising strategy utilizing a tumor-targeting alkylphosphocholine (NM600) radiolabeled with 177Lu for targeted radionuclide therapy (TRT) of TNBC. In two murine syngeneic models of TNBC, we confirmed excellent tumor targeting and rapid normal tissue clearance of the PET imaging analog 86Y-NM600. Based on longitudinal PET/CT data acquired with 86Y-NM600, we estimated the dosimetry of therapeutic 177Lu-NM600, which showed larger absorbed doses in the tumor compared to normal tissues. Administration of 177Lu-NM600 resulted in significant tumor growth inhibition and prolonged overall survival in mice bearing syngeneic 4T07 and 4T1 tumors. Complete response was attained in 60% of 4T07 bearing mice, but animals carrying aggressive 4T1 tumor grafts succumbed to metastatic progression. The injected activities used for treatment (9.25 and 18.5 MBq) were well tolerated, and only mild transient cytopenia was noted. Overall, our results suggest that 177Lu-NM600 TRT has potential for treatment of TNBC and merits further exploration in a clinical setting.




io

212Pb Alpha-Radioimmunotherapy targeting CD38 in Multiple Myeloma: a preclinical study.

Multiple myeloma (MM) is a plasma cell cancer and represents the second most frequent hematological malignancy. Despite new treatments and protocols including high doses chemotherapy associated with autologous stem cell transplantation, the prognosis of MM patients is still poor. Alpha-radioimmunotherapy (alpha-RIT) represents an attractive treatment strategy due to the high linear energy transfer and short path length of alpha-radiation in tissues, resulting in high tumor cell killing and low toxicity to surrounding tissues. In this study, we investigated the potential of alpha-RIT with 212Pb-Daratumumab (anti-CD38), in both in vitro and in vivo models, as well as an anti-mouse CD38 antibody using in vivo models. Methods: Inhibition of cell proliferation after incubation of RPMI8226 cell line with increasing activities (0.185-3.7 kBq/ml) of 212Pb-isotypic control or 212Pb-Daratumumab was evaluated. Biodistribution was performed in vivo by SPECT-CT imaging and post-mortem. Dose range finding (DRF) and acute toxicity studies were conducted. As Daratumumab does not bind the murine CD38, biodistribution and DRF were also determined using an anti-murine CD38 antibody. To evaluate in vivo efficacy of 212Pb-Daratumumab, mice were engrafted subcutaneously with 5.106 RPMI8226 cells. Mice were treated 13 days post-engraftment with an intravenous injection of 212Pb-Daratumumab or control solutions. Therapeutic efficacy was monitored by tumor volume measurements and overall survival. Results: Significant inhibition of proliferation of the human myeloma RPMI8226 cell line was observed after three days of incubation with 212Pb-Daratumumab compared to 212Pb-Isotypic Control or cold antibodies. Biodistribution studies showed a specific tumoral accumulation of Daratumumab. No toxicity was observed with 212Pb-Daratumumab up to 370 kBq due to the lack of cross-reactivity. Nevertheless, acute toxicity experiments with 212Pb-anti-mCD38 established a toxic activity of 277.5 kBq. To remain within realistically safe treatment activities for efficacy studies, mice were treated with 185 kBq or 277.5 kBq of 212Pb-Daratumumab. Marked tumor growth inhibition compared to controls was observed, with a median survival of 55 days for 277.5 kBq of 212Pb-Daratumumab instead of 11 for PBS control groups. Conclusion: These results showed 212Pb-Daratumumab efficacy on xenografted mice with significant tumor regression and increased survival. This study highlights alpha-RIT potency in MM treatment.




io

Positron lymphography via intracervical 18F-FDG injection for pre-surgical lymphatic mapping in cervical and endometrial malignancies

Rationale: The presence of metastasis in local lymph nodes (LNs) is a key factor influencing choice of therapy and prognosis in cervical and endometrial cancers; therefore, the exploration of sentinel LNs (SLNs) is highly important. Currently, however, SLN mapping requires LN biopsy for pathologic evaluation, since there are no clinical imaging approaches that can identify tumor-positive LNs in early stages. Staging lymphadenectomy poses risks, such as leg lymphedema or lymphocyst formation. Furthermore, in 80% to 90% of patients, the explored LNs are ultimately tumor free, meaning the vast majority of patients are unnecessarily subjected to lymphadenectomy. Methods: Current lymphoscintigraphy methods only identify the anatomic location of the SLNs but do not provide information on their tumor status. There are no non-invasive methods to reliably identify metastases in LNs before surgery. We have developed positron lymphography (PLG), a method to detect tumor-positive LNs, where 18F-fluoro-2-deoxy-D-glucose (18F-FDG) is injected interstitially into the uterine cervix the day of surgery, and its rapid transport through the lymphatic vessels to the SLN is then visualized with dynamic positron emission tomography/computed tomography (PET/CT). We previously showed that PLG was able to identify metastatic LNs in animal models. Here, we present the first results from our pilot clinical trial (clinical trials identifier NCT02285192) in 23 patients with uterine or cervical cancer. On the morning of surgery, 18F-FDG was injected into the cervix, followed by an immediate dynamic PET/CT scan of the pelvis and a delayed 1-h whole body scan. Results: There were 3 (15%) node-positive cases on final pathologic analysis, and all LNs (including one with a focus of only 80 tumor cells) were identified by PLG except one node with an 11-mm micrometastasis. There were 2 (10%) false-positive cases with PLG, in which final pathology of the corresponding SLNs was negative for tumor. Methods: Current lymphoscintigraphy methods only identify the anatomic location of the SLNs but do not provide information on their tumor status. There are no non-invasive methods to reliably identify metastases in LNs before surgery. We have developed positron lymphography (PLG), a method to detect tumor-positive LNs, where 18F-fluoro-2-deoxy-D-glucose (18F-FDG) is injected interstitially into the uterine cervix the day of surgery, and its rapid transport through the lymphatic vessels to the SLN is then visualized with dynamic positron emission tomography/computed tomography (PET/CT). We previously showed that PLG was able to identify metastatic LNs in animal models. Here, we present the first results from our pilot clinical trial (clinical trials identifier NCT02285192) in 23 patients with uterine or cervical cancer. On the morning of surgery, 18F-FDG was injected into the cervix, followed by an immediate dynamic PET/CT scan of the pelvis and a delayed 1-h whole body scan. Results: There were 3 (15%) node-positive cases on final pathologic analysis, and all LNs (including one with a focus of only 80 tumor cells) were identified by PLG, except for one node with an 11-mm micrometastasis. There were 2 (10%) false-positive cases with PLG, in which final pathology of the corresponding SLNs was negative for tumor. Conclusion: This first-in-human study of PLG in women with uterine and cervical cancer demonstrates its feasibility and its ability to identify patients with nodal metastases, and warrants further evaluation in additional studies.




io

Evaluation of 11C-NR2B-SMe and its Enantiomers as PET Radioligands for Imaging the NR2B Subunit within the NMDA Receptor Complex in Rats

[S-Methyl-11C](±)-7-methoxy-3-(4-(4-(methylthio)phenyl)butyl)-2,3,4,5-tetrahydro-1H-benzo[d]azepin-1-ol (11C-NR2B-SMe) and its enantiomers were synthesized as candidates for imaging the NR2B subunit within the N-methyl-D-aspartate receptor with positron emission tomography (PET). Methods: Brains were scanned with PET for 90 min after intravenous injection of one of the candidate radioligands into rats. To detect any NR2B specific binding of radioligand in brain, various pre-blocking or displacing agents were evaluated for their impact on the PET brain imaging data. Radiometabolites from brain and other tissues were measured ex vivo and in vitro. Results: Each radioligand gave high early whole brain uptake of radioactivity, followed by a brief fast decline and then a slow final decline. 11C-(S)-NR2B-SMe was studied extensively. Ex vivo measurements showed that radioactivity in rat brain at 30 min after radioligand injection was virtually unchanged radioligand. Only less lipophilic radiometabolites appeared in plasma. High-affinity NR2B ligands, Ro-25-6981, ifenprodil, and CO10124, showed increasing preblock of whole brain radioactivity retention with increasing dose (0.01 to 1.25 mg/kg, i.v.). Five 1 antagonists (FTC146, BD1407, F3, F4, and NE100) and four 1 agonists ((+)-pentazocine, (±)-PPCC, PRE-084, (+)-SKF10047) were ineffective preblocking agents, except FTC146 and F4 at high dose. Two potent 1 receptor agonists, TC1 and SA4503, showed dose-dependent preblocking effects in the presence or absence of pharmacological 1 receptor blockade with FTC146. Conclusion: 11C-(S)-NR2B-SMe has adequate NR2B-specific PET signal in rat brain to warrant further evaluation in higher species. TC1 and SA4503 likely have off-target binding to NR2B in vivo.




io

Light-induced radiosynthesis of 89ZrDFO-azepin-onartuzumab for imaging the hepatocyte growth factor receptor

Methods that provide rapid access to radiolabeled antibodies are vital in the development of diagnostic and radiotherapeutic agents for positron emission tomography (PET) or radioimmunotherapy. The human hepatocyte growth factor receptor (c-MET) signaling pathway is dysregulated in a number of malignancies including gastric cancer, and is an important biomarker in drug discovery. Here, we used a photoradiochemical approach to produce 89Zr-radiolabeled onartuzumab (a monovalent, anti-human c-MET antibody), starting directly from the fully formulated drug (MetMAb). Methods: Simultaneous 89Zr-radiolabeling and protein conjugation was performed in one-pot reactions containing 89Zr-oxalate, the photoactive chelate DFO-aryl azide (DFO-ArN3) and MetMAb to give 89ZrDFO-azepin-onartuzumab. As a control, 89ZrDFO-Bn-NCS-onartuzumab was prepared via a conventional two-step process using pre-purified onartuzumab and DFO-Bn-NCS. Radiotracers were purified by using size-exclusion methods and evaluated by radiochromatography. Radiochemical stability was studied in human serum and immunoreactivity was determined by cellular binding assays using MKN-45 gastric carcinoma cells. PET imaging at multiple time points (0–72 h) was performed in female athymic nude mice bearing subcutaneous MKN-45 xenografts. Biodistribution experiments were performed after the final image. Tumor specificity of 89ZrDFO-azepin-onartuzumab was assessed by competitive inhibition (blocking) studies. Results: Initial photoradiosynthesis experiments produced 89ZrDFO-azepin-onartuzumab in <15 min. with an isolated decay-corrected radiochemical yield (RCY) of 24.8%, a radiochemical purity (RCP) ~90% and a molar activity (Am) of ~1.5 MBq nmol-1. Reaction optimization improved the radiochemical conversion (RCC) of 89ZrDFO-azepin-onartuzumab to 56.9±4.1% (n = 3), with isolated RCYs of 41.2±10.6% (n = 3), and RCPs >90%. Conventional methods produced 89ZrDFO-Bn-NCS-onartuzumab with isolated RCY >97%, RCP >97% and Am ~14.0 MBq nmol-1. Both radiotracers were immunoreactive and stable in human serum. PET imaging and biodistribution studies showed high tumor uptake for both radiotracers. By 72 h, tumor and liver uptake reached 15.37±5.21 %ID g-1, 6.56±4.03 %ID g-1, respectively for 89ZrDFO-azepin-onartuzumab (n = 4), and 21.38±11.57 %ID g-1 and 18.84±6.03 %ID g-1 for 89ZrDFO-Bn-NCS-onartuzumab (n = 4). Blocking experiments gave a statistically significant reduction in tumor uptake (6.34±0.47 %ID g-1) of 89ZrDFO-azepin-onartuzumab (n = 4). Conclusion: Experiments demonstrate that photoradiosynthesis is a viable alternative approach for producing 89Zr-radiolabeled antibodies direct in protein formulation buffer which reduces protein aggregation and liver uptake.




io

Impact of 68Ga-PSMA-11 PET/CT on Staging and Management of Prostate Cancer Patients in Various Clinical Settings: A Prospective Single Center Study

The impact of prostate specific membrane antigen (PSMA) PET/CT on management of prostate cancer (PCa) patients with biochemical recurrence (BCR) is well-established. However, whether and how PSMA PET/CT affects the management of patients undergoing scans for other clinical indications remains unknown. The goal of this study was to determine the impact of 68Ga-PSMA-11 PET/CT on initial and subsequent management decisions in a cohort of PCa patients referred for various indications ("basket trial") excluding the two main classical indications: BCR and presurgical staging. Methods: This was a prospective study of 197 patients that aimed to determine the impact of 68Ga-PSMA-11 PET/CT on PCa stage and management. Indications for PSMA PET/CT were: initial staging of non-surgical candidates (30 patients) and re-staging after definitive treatment (n = 168). The re-staging cohort comprised: patients re-staged with known advanced metastatic disease (n = 103), after androgen deprivation therapy only (n = 16), after surgery with serum PSA levels <0.2 ng/ml (n = 13), after radiation therapy (RT) not meeting the Phoenix criteria (n = 22) and after other primary local treatments [i.e. high-intensity focused ultrasound (HIFU), focal laser ablation, cryoablation, hyperthermia or irreversible electroporation] (n = 13). Patients with BCR and candidates for curative surgery were excluded. Impact on management was assessed using pre- and post-PET questionnaires completed by referring physicians, electronic chart review and/or patient telephone encounters. Results: PSMA PET/CT changed disease stage in 135/197 (69%) patients (38% up-stage, 30% down-stage and no changes in stage in 32%). Management was affected in 104/182 (57%) patients. Specifically, PSMA PET/CT impacted management of patients who were re-staged after RT without meeting the Phoenix criteria for BCR, after other definitive local treatments and with advanced metastatic disease in 13/18 (72%), 8/12 (67%) and 59/96 (61%), respectively. Conclusion: PSMA PET/CT has a profound impact on stage and management of PCa patients outside of the two main classical indications (BCR and presurgical staging) across all examined clinical scenarios.




io

Projection-space implementation of deep learning-guided low-dose brain PET imaging improves performance over implementation in image-space

Purpose: To assess the performance of full dose (FD) positron emission tomography (PET) image synthesis in both image and projection space from low-dose (LD) PET images/sinograms without sacrificing diagnostic quality using deep learning techniques. Methods: Clinical brain PET/CT studies of 140 patients were retrospectively employed for LD to FD PET conversion. 5% of the events were randomly selected from the FD list-mode PET data to simulate a realistic LD acquisition. A modified 3D U-Net model was implemented to predict FD sinograms in the projection-space (PSS) and FD images in image-space (PIS) from their corresponding LD sinograms/images, respectively. The quality of the predicted PET images was assessed by two nuclear medicine specialists using a five-point grading scheme. Quantitative analysis using established metrics including the peak signal-to-noise ratio (PSNR), structural similarity index metric (SSIM), region-wise standardized uptake value (SUV) bias, as well as first-, second- and high-order texture radiomic features in 83 brain regions for the test and evaluation dataset was also performed. Results: All PSS images were scored 4 or higher (good to excellent) by the nuclear medicine specialists. PSNR and SSIM values of 0.96 ± 0.03, 0.97 ± 0.02 and 31.70 ± 0.75, 37.30 ± 0.71 were obtained for PIS and PSS, respectively. The average SUV bias calculated over all brain regions was 0.24 ± 0.96% and 1.05 ± 1.44% for PSS and PIS, respectively. The Bland-Altman plots reported the lowest SUV bias (0.02) and variance (95% CI: -0.92, +0.84) for PSS compared with the reference FD images. The relative error of the homogeneity radiomic feature belonging to the Grey Level Co-occurrence Matrix category was -1.07 ± 1.77 and 0.28 ± 1.4 for PIS and PSS, respectively Conclusion: The qualitative assessment and quantitative analysis demonstrated that the FD PET prediction in projection space led to superior performance, resulting in higher image quality and lower SUV bias and variance compared to FD PET prediction in the image domain.




io

Will SPECT/CT Cameras soon be able to display Absorbed Doses? Dosimetry from Single Activity Concentration Measurements.




io

Individual mapping of innate immune cell activation is a candidate marker of patient-specific trajectories of disability worsening in Multiple Sclerosis

Objective: To develop a novel approach to generate individual maps of white matter (WM) innate immune cell activation using 18F-DPA-714 translocator protein (TSPO) positron emission tomography (PET), and to explore the relationship between these maps and individual trajectories of disability worsening in patients with multiple sclerosis (MS). Methods: Patients with MS (n = 37), whose trajectories of disability worsening over the 2 years preceding study entry were calculated, and healthy controls (n = 19) underwent magnetic resonance magnetic and 18F-DPA-714 PET. A threshold of significant activation of 18F-DPA-714 binding was calculated with a voxel-wise randomized permutation-based comparison between patients and controls, and used to classify each WM voxel in patients as characterized by a significant activation of innate immune cells (DPA+) or not. Individual maps of innate immune cell activation in the WM were employed to calculate the extent of activation in WM regions-of-interests and to classify each WM lesion as "DPA-active", "DPA-inactive" or "unclassified". Results: Compared with the WM of healthy controls, patients with MS had a significantly higher percentage of DPA+ voxels in the normal-appearing WM, (NAWM in patients=24.9±9.7%; WM in controls=14.0±7.8%, p<0.001). In patients with MS, the percentage of DPA+ voxels showed a significant increase from NAWM, to perilesional areas, T2 hyperintense lesions and T1 hypointense lesions (38.1±13.5%, 45.0±17.9%, and 51.9±22.9%, respectively, p<0.001). Among the 1379 T2 lesions identified, 512 were defined as DPA-active and 258 as DPA-inactive. A higher number of lesions classified as DPA-active (OR=1.13, P = 0.009), a higher percentage of DPA+ voxels in the NAWM (OR=1.16, P = 0.009) and in T1-spin-echo lesions (OR=1.06, P = 0.036), were significantly associated with a retrospective more severe clinical trajectory in patients with MS. Conclusion: A more severe trajectory of disability worsening in MS is associated with an innate immune cells activation inside and around WM lesions. 18F-DPA-714 PET may provide a promising biomarker to identify patients at risk of severe clinical trajectory.




io

Demarcation of Sepsis-Induced Peripheral and Central Acidosis with pH-Low Insertion Cyclic (pHLIC) Peptide

Acidosis is a key driver for many diseases, including cancer, sepsis, and stroke. The spatiotemporal dynamics of dysregulated pH across disease remains elusive and current diagnostic strategies do not provide localization of pH alterations. We sought to explore if PET imaging using hydrophobic cyclic peptides that partition into the cellular membrane at low extracellular pH (denoted as "pHLIC") can permit accurate in vivo visualization of acidosis. Methods: Acid-sensitive cyclic peptide c[E4W5C] pHLIC was conjugated to bifunctional maleimide-NO2A and radiolabeled with copper-64 (t1/2 = 12.7 h). C57BL/6J mice were administered LPS (15 mg/kg) or saline (vehicle) and serially imaged with [64Cu]Cu-c[E4W5C] over 24 h. Ex vivo autoradiography was performed on resected brain slices and subsequently stained with cresyl violet to enable high-resolution spatial analysis of tracer accumulation. A non- pH-sensitive cell-penetrating control peptide (c[R4W5C]) was used to confirm specificity of [64Cu]Cu-c[E4W5C]. CD11b (macrophage/microglia) and TMEM119 (microglia) immunostaining was performed to correlate extent of neuroinflammation with [64Cu]Cu-c[E4W5C] PET signal. Results: [64Cu]Cu-c[E4W5C] radiochemical yield and purity was >95% and >99% respectively, with molar activity >0.925 MBq/nmol. Significantly increased [64Cu]Cu-c[E4W5C] uptake was observed in LPS-treated mice (vs. vehicle) within peripheral tissues including blood, lungs, liver, and small intestines (P < 0.001-0.05). Additionally, there was significantly increased [64Cu]Cu-c[E4W5C] uptake in the brains of LPS-treated animals. Autoradiography confirmed increased uptake in the cerebellum, cortex, hippocampus, striatum, and hypothalamus of LPS-treated mice (vs. vehicle). Immunohistochemical (IHC) analysis revealed microglial/macrophage infiltrate, suggesting activation in brain regions containing increased tracer uptake. [64Cu]Cu-c[R4W5C] demonstrated significantly reduced uptake in the brain and periphery of LPS mice compared to the acid-mediated [64Cu]Cu-c[E4W5C] tracer. Conclusion: Here, we demonstrate that a pH-sensitive PET tracer specifically detects acidosis in regions associated with sepsis-driven pro-inflammatory responses. This study suggests that [64Cu]Cu-pHLIC is a valuable tool to noninvasively assess acidosis associated with both central and peripheral innate immune activation.




io

Improved Alignment of PET and CT Images in Whole-Body PET/CT in Cases of Respiratory Motion During CT

Respiratory motion during the CT and PET parts of a PET/CT scan leads to imperfect alignment of anatomical features seen by the two modalities. In this work, we concentrate on the effects of motion during CT. We propose a novel approach for improving the alignment. Methods: Respiratory waveform data were gathered during the CT and PET parts of 28 PET/CT scans of cancer patients with 40 lesions up to 3 cm size in the lung or upper abdomen. PET list-mode data were reconstructed by three reconstruction methods: PET/static, PET/EX or end of expiration (OncoFreeze), and a novel PET/matched method that used both waveforms. The three methods were compared. The distance between tumor positions in PET and CT were characterized in visual interpretation by physicians as well as quantitatively. Tumor standardized uptake values (SUVmax and SUVpeak) were determined relative to SUV based on the static method. Image noise was evaluated in the liver and compared to PET/static. Results: In visual interpretation, the rate of good alignment was 13/21, 13/23 and 18/21 for PET/static, PET/EX and PET/matched methods, respectively, and the mean PET-CT distances were 3.5, 5.1 and 2.8 mm. In visual comparison with PET/EX, the rate of good alignment was increased in 1/10 and 7/10 cases for PET/static and PET/matched. SUVmax was on average 21% higher than PET/static when either PET/EX or PET/matched was used. SUVpeak was 12% higher. Image noise in the liver was 15% higher than static for the PET/EX method, and 40% higher for PET/matched; that is, noise was much lower than in gated PET. Conclusion: Acquiring respiratory waveforms both in PET (as in the current state of the art) and in CT (an unusual key step in this approach) has the potential to improve the alignment of PET and CT images. A proposed method for using this information was tested. Improved alignment was demonstrated.




io

In vivo instability of 177Lu-DOTATATE during peptide receptor radionuclide therapy

Peptide receptor radiotherapy using 177Lu-labeled somatostatin ligand analogs is a well-established treatment for neuroendocrine tumors (NET), with 177Lu-DOTATATE having acquired marketing authorization in Europe and the USA. The investigation of the pharmacokinetics of those radiopharmaceuticals in vivo in humans is crucial for personalized treatment management and understanding of treatment effects. It requires input data on the in vivo stability of the radiopharmaceuticals in blood and plasma. The work presented here is devoted to the investigation of in vivo stability of 177Lu-DOTATATE in humans affected by NET. Unexpectedly, fast metabolism of the radiopharmaceutical was observed, with fraction of intact 177Lu-DOTATATE in plasma decreasing rapidly to 23±5% (mean ± SD) at 24 h and 1.7±0.9% at 96 h after injection.




io

Efficacy of Peptide Receptor Radionuclide Therapy for Esthesioneuroblastoma

Objectives: Esthesioneuroblastoma (ENB) is rare with limited therapeutic options when unresectable or metastatic; however, expression of somatostatin receptors qualifies it for peptide receptor radionuclide therapy (PRRT). We report outcomes of PRRT in ENB from two referral centers. Methods: Using PRRT databases at two European Neuroendocrine Tumour Society Centers of Excellence, case finding was undertaken between 2004-2018 for patients who had PRRT with recurrent/metastatic ENB deemed unsuitable for further conventional therapies. Evaluations of response using a composite reference standard and for survival were performed. Results: Of seven patients, four had partial response, two had disease stabilization and one had early progression. Possible side effects include worsening CSF-leaks. Median progression-free survival was 17 months (range, 0-30), and median overall survival was 32 months (range, 4–53). Conclusion: PRRT shows promising efficacy and moderate survival duration in unresectable locally advanced or metastatic ENB warranting larger cohort studies incorporating measures of quality of life.




io

Tobacco smoking in people is not associated with altered 18 kDa-translocator protein levels: A Positron Emission Tomography study

Rationale: The effects of tobacco smoking on the brain’s immune system are not well elucidated. While nicotine is immunosuppressive, other constituents in tobacco smoke have inflammatory effects. Positron Emission Tomography (PET) imaging of the 18-kDa translocator protein (TSPO) provide a biomarker for microglia, the brain’s primary immunocompetent cells. This work compared brain TSPO levels in 20 tobacco smokers (abstinent for at least 2 hours) and 20 nonsmokers using a fully quantitative modeling approach for the first time. Methods: [11C]PBR28 PET scans were acquired with arterial blood sampling to estimate the metabolite-corrected input function. [11C]PBR28 volumes of distribution (VT) were estimated throughout the brain with multilinear analysis. Results: Statistical analyses revealed no evidence for significant differences in regional [11C]PBR28 VT between smokers and non-smokers (whole-brain Cohen’s d=0.09) despite adequate power to detect medium effect sizes. Conclusion: These findings inform previous PET studies reporting lower TSPO radiotracer concentrations in brain (measured as standardized uptake value, SUV) of tobacco smokers compared to nonsmokers by demonstrating the importance of accounting for radiotracer concentrations in plasma. These findings suggest that compared to nonsmokers, smokers have comparable TSPO levels in brain. Additional work with other biomarkers is needed to fully characterize effects of tobacco smoking on the brain’s immune system.




io

Flare phenomenon in O-(2-[18F]-Fluoroethyl)-L-Tyrosine PET after resection of gliomas

Purpose: PET using O-(2-[18F]Fluoroethyl)-L-tyrosine (18F-FET) is useful to detect residual tumor tissue after glioma resection. Recent animal experiments detected reactive changes of 18F-FET uptake at the rim of the resection cavity within the first two weeks after resection of gliomas. In the present study, we evaluated pre- and postoperative 18F-FET PET scans of glioma patients with particular emphasis on the identification of reactive changes after surgery. Methods: Forty-three patients with cerebral gliomas (9 low-grade, 34 high-grade; 9 primary tumors, 34 recurrent tumors) who had preoperative (time before surgery, median 23 d, range 6-44 d) and postoperative 18F-FET-PET (time after surgery, median 14, range 5–28 d) were included. PET scans (20-40 min p.i.) were evaluated visually for complete or incomplete resection (CR, IR) and compared with MRI. Changes of 18F-FET-uptake in residual tumor were evaluated by tumor-to-brain ratios (TBRmax) and in the vicinity of the resection cavity by maximum lesion-to-brain ratios (LBRmax). Results: Visual analysis of 18F-FET PET scans revealed CR in 16/43 patients and IR in the remaining patients. PET results were concordant with MRI in 69% of the patients. LBRmax of 18F-FET uptake in the vicinity of the resection cavity was significantly higher compared with preoperative values (1.59 ± 0.36 versus 1.14 ± 0.17; n = 43, p<0.001). In 11 patients (26%) a "flare phenomenon" was observed with a considerable increase of 18F-FET uptake compared with preoperative values in either the residual tumor (n = 5) or in areas remote from tumor in the preoperative PET scan (n = 6) (2.92 ± 1.24 versus 1.62 ± 0.75; p<0.001). Further follow-up in five patients showed decreasing 18F-FET uptake in the flare areas in four and progress in one case. Conclusion: Our study confirms that 18F-FET PET provides valuable information for assessing the success of glioma resection. Postoperative reactive changes at the rim of the resection cavity appear to be mild. However, in 23 % of the patients, a postoperative "flare phenomenon" was observed that warrants further investigation.




io

18F-FDG PET/CT in the Diagnostic and Treatment Evaluation of Pediatric Post-transplant Lymphoproliferative Disorders

We aimed to evaluate the diagnostic performance of 18F-FDG PET/CT for the detection of post-transplantation lymphoproliferative disorder (PTLD) in a pediatric population and explore its feasibility during response assessment. Methods: This retrospective study included 28 pediatric transplant recipients who underwent a total of 32 18F-FDG PET/CT scans due to clinical suspicion of PTLD within an 8-year period. Pathology reports and 2-year follow-up were used as reference standard. Twenty-one response assessment 18F-FDG PET/CT scans were re-evaluated according to the Lugano criteria. Results: The diagnosis of PTLD was established in 14 patients (49%). Sensitivity, specificity, positive predictive value, and negative predictive value of 18F-FDG PET/CT for the detection of PTLD in children with a clinical suspicion of this disease, was 50% (7/14), 100% (18/18), 100% (7/7), and 72% (18/25), respectively. False-negative results occurred in patients with PTLD in the Waldeyer’s ring, cervical lymph nodes or small bowel with either non-destructive or polymorphic PTLD. Two of 5 interim 18F-FDG PET/CT scans and 3 of 9 end-of-treatment 18F-FDG PET/CT scans were false-positive. Conclusion: 18F-FDG PET/CT had good specificity and positive predictive value but low to moderate sensitivity and negative predictive value for the detection of PTLD in a 28 pediatric patient cohort with a clinical suspicion of this disease. False-negative results were confirmed in the Waldeyer’s ring, cervical lymph nodes and small bowel with either non-destructive or polymorphic PTLD subtypes. 18F-FDG PET/CT appears to have a limited role in the response assessment setting of pediatric PTLD, given the observed high proportions of false-positives both at interim and end-of-treatment evaluations.




io

PSMA PET/CT and standard plus PET/CT-Ultrasound fusion targeted prostate biopsy can diagnose clinically significant prostate cancer in men with previous negative biopsies

The purpose of this study was to investigate the feasibility and diagnostic efficacy of 68Ga-PSMA positron emission tomography/computed tomography (PET/CT) combined with PET-ultrasound image-guided biopsy in the diagnosis of prostate cancer. Methods: A total of 31 patients with previously negative prostate biopsy, but persistent elevated serum prostate specific antigen (PSA), were imaged with a 68Ga-labeled prostate-specific membrane antigen (PSMA) PET/CT ligand prior to undergoing repeat prostate biopsy. Based on the proposed PROMISE criteria, PSMA PET/CT results were interpreted as negative (miPSMA-ES 0-1) or positive (miPSMA-ES 2-3). All patients underwent standard template systematic biopsy with up to four additional PSMA PET-ultrasound fusion image-guided biopsy cores. The sensitivity, specificity, positive and negative predictive values, and accuracy of PSMA PET/CT were determined. In addition, the correlation between miPSMA-ES and detection rate of prostate cancer was also analyzed. Univariate logistic regression models were established using PSMA PET/CT semi-quantitative analysis parameters to predict the outcome of repeat prostate biopsy. Results: The median age of patients was 65 years (range 53-81), and the median PSA level was 18.0 ng/ml (range 5.48-49.77 ng/ml). Prostate cancer was detected in 15/31 patients (48.4%) and 12/31 patients (38.7%) had clinically significant disease. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 68Ga-PSMA PET/CT in the diagnosis of clinically significant prostate cancer were 100.0%, 68.4%, 66.7%, 100.0% and 80.6%, respectively. The detection rate of prostate cancer increased with the increase of miPSMA-ES score. The detection rate of clinically significant prostate cancer in miPSMA-ES 0-1, 2 and 3 groups were 0%, 54.5% and 85.7% respectively. Semi-quantitative analysis of 68Ga-PSMA PET/CT images showed that predictive models based on maximum standardized uptake value (SUVmax), tumor-to-background normal prostate SUV (SUVT/BGp) and tumor-to-background normal liver SUV (SUVratio) could effectively predict clinically significant prostate cancer; area under the curves were 0.930, 0.877, and 0.956, respectively. Conclusion: This study preliminarily confirmed that 68Ga-PSMA PET/CT imaging combined with PET-ultrasound fusion image-guided prostate biopsy can effectively detect clinically significant prostate cancer. Prebiopsy 68Ga-PSMA PET/CT has predictive value for clinically significant cancer in the studied patient population.




io

Imaging the Distribution of Gastrin Releasing Peptide Receptors in Cancer

Targeting tumor-expressed receptors using selective molecules for diagnostic, therapeutic or both diagnostic and therapeutic (theragnostic) purposes is a promising approach in oncological applications. Such approaches have increased significantly over the past decade. Peptides such as gastrin-releasing peptide receptors (GRPR) targeting radiopharmaceuticals are small molecules with fast blood clearance and urinary excretion. They demonstrate good tissue diffusion, low immunogenicity, and highly selective binding to their target cell-surface receptors. They are also easily produced. GRPR, part of the bombesin (BBN) family, are overexpressed in many tumors, including breast and prostate cancer, and therefore represent an attractive target for future development.




io

Data-driven motion detection and event-by-event correction for brain PET: Comparison with Vicra

Head motion degrades image quality and causes erroneous parameter estimates in tracer kinetic modeling in brain PET studies. Existing motion correction methods include frame-based image-registration (FIR) and correction using real-time hardware-based motion tracking (HMT) information. However, FIR cannot correct for motion within one predefined scan period while HMT is not readily available in the clinic since it typically requires attaching a tracking device to the patient. In this study, we propose a motion correction framework with a data-driven algorithm, i.e., using the PET raw data itself, to address these limitations. Methods: We propose a data-driven algorithm, Centroid of Distribution (COD), to detect head motion. In COD, the central coordinates of the line of response (LOR) of all events are averaged over 1-sec intervals to generate a COD trace. A point-to-point change in the COD trace in one direction that exceeded a user-defined threshold was defined as a time point of head motion, which was followed by manually adding additional motion time points. All the frames defined by such time points were reconstructed without attenuation correction and rigidly registered to a reference frame. The resulting transformation matrices were then used to perform the final motion compensated reconstruction. We applied the new COD framework to 23 human dynamic datasets, all containing large head motions, with 18F-FDG (N = 13) and 11C-UCB-J (N = 10), and compared its performance with FIR and with HMT using the Vicra, which can be considered as the "gold standard". Results: The COD method yielded 1.0±3.2% (mean ± standard deviation across all subjects and 12 grey matter regions) SUV difference for 18F-FDG (3.7±5.4% for 11C-UCB-J) compared to HMT while no motion correction (NMC) and FIR yielded -15.7±12.2% (-20.5±15.8%) and -4.7±6.9% (-6.2±11.0%), respectively. For 18F-FDG dynamic studies, COD yielded differences of 3.6±10.9% in Ki value as compared to HMT, while NMC and FIR yielded -18.0±39.2% and -2.6±19.8%, respectively. For 11C-UCB-J, COD yielded 3.7±5.2% differences in VT compared to HMT, while NMC and FIR yielded -20.0±12.5% and -5.3±9.4%, respectively. Conclusion: The proposed COD-based data-driven motion correction method outperformed FIR and achieved comparable or even better performance as compared to the Vicra HMT method in both static and dynamic studies.




io

Clinical evaluation of a data-driven respiratory gating algorithm for whole-body positron emission tomography with continuous bed motion

Respiratory gating is the standard to overcome respiration effects degrading image quality in positron emission tomography (PET). Data-driven gating (DDG) using signals derived from PET raw data are promising alternatives to gating approaches requiring additional hardware. However, continuous bed motion (CBM) scans require dedicated DDG approaches for axially-extended PET, compared to DDG for conventional step-and-shoot scans. In this study, a CBM-capable DDG algorithm was investigated in a clinical cohort, comparing it to hardware-based gating using gated and fully motion-corrected reconstructions. Methods: 56 patients with suspected malignancies in thorax or abdomen underwent whole-body 18F-FDG CBM-PET/CT imaging using DDG and hardware-based respiratory gating (pressure-sensitive belt gating, BG). Correlation analyses were performed on both gating signals. Besides static reconstructions, BG and DDG were used for optimally-gated PET (BG-OG, DDG-OG) and fully motion-corrected PET (elastic motion correction; BG-EMOCO, DDG-EMOCO). Metabolic volumes, SUVmax and SUVmean of lesions were compared amongst the reconstructions. Additionally, the quality of lesion delineation in different PET reconstructions was independently evaluated by three experts. Results: Global correlation coefficients between BG and DDG signals amounted to 0.48±0.11, peaking at 0.89±0.07 when scanning the kidney and liver region. In total, 196 lesions were analyzed. SUV measurements were significantly higher in BG-OG, DDG-OG, BG-EMOCO and DDG-EMOCO compared to static images (P<0.001; median SUVmax: static, 14.3±13.4; BG-EMOCO, 19.8±15.7; DDG-EMOCO, 20.5±15.6; BG-OG, 19.6±17.1; DDG-OG, 18.9±16.6). No significant differences between BG-OG and DDG-OG, and BG-EMOCO and DDG-EMOCO, respectively, were found. Visual lesion delineation was significantly better in BG-EMOCO and DDG-EMOCO than in static reconstructions (P<0.001); no significant difference was found comparing BG and DDG (EMOCO, OG, respectively). Conclusion: DDG-based motion-compensation of CBM-PET acquisitions outperforms static reconstructions, delivering qualities comparable to hardware-based approaches. The new algorithm may be a valuable alternative for CBM-PET systems.




io

Multi-phasic 68Ga-PSMA PET/CT in detection of early recurrence in prostate cancer patients with PSA < 1 ng/ml: a prospective study of 135 cases.

Purpose: The main objective of this prospective study was to determine the impact of multi-phasic acquisition of 68Ga-PSMA PET/CT in the detection of recurrent prostate cancer (PCa) in the early stage of biochemical recurrence (BR) with prostate-serum-antigen (PSA) level <1ng/ml. Also, 68Ga-PSMA PET/CT positivity was correlated with clinical parameters for the assessment of predictive markers. Methods: A prospective monocentric study was conducted on 135 PCa patients with BR and PSA<1ng/ml. All patients have undergone initial prostatectomy with additional radiation therapy in 19.3% and androgen-deprivation therapy (ADT) in 7.4% of patients. Dynamic acquisition [1–8min. post-injection (p.i.)] from the prostate bed, standard whole-body (60min. p.i.) and limited bed positions of delayed studies (120-150min. p.i.), were performed. Studies were reviewed by two board-certified nuclear medicine specialists, independently. A combination of visual and semi-quantitative analyses and correlation with morphological (e.g. MRI) and/or clinical follow-up findings was used for the final interpretation of abnormal lesions as benign or malignant. 68Ga-PSMA PET/CT positivity was also correlated with primary clinical findings. Results: Incorporating the information of all phases, 116 lesions were detected in 49.6% of patients (22 local recurrences, 63 lymph nodes, and 31 distant metastases). The detection rates were 31.8%, 44.9%, and 71.4% for PSA<0.2ng/ml, 0.2≤PSA<0.5, and 0.5≤PSA<1, respectively. Additional dynamic and/or delayed phases resulted in better determination of equivocal lesions and a higher diagnostic performance in 25.9% of patients. Stand-alone dynamic and delayed images led to better interpretation of equivocal findings in the prostate bed (31.4%) and other (lymph node/bone) lesions (20%), respectively. Conclusion: 68Ga-PSMA PET/CT revealed promising results for the early detection of recurrent disease in patients with PSA level of 0.5-1.0ng/ml. However, it showed limited value in cases with PSA<0.5ng/ml. Multi-phasic 68Ga-PSMA PET/CT led to better determination of equivocal findings. Although, dynamic images may provide helpful information in assessment of the prostate bed; however, delayed acquisitions seem to have higher impact in clarifying of the equivocal findings.




io

Performance of digital PET compared to high-resolution conventional PET in patients with cancer

Recently introduced PET systems using silicon photomultipliers with digital readout (dPET) have an improved timing and spatial resolution, aiming at a better image quality, over conventional PET (cPET) systems. We prospectively evaluated the performance of a dPET system in patients with cancer, as compared to high-resolution (HR) cPET imaging. Methods: After a single FDG-injection, 66 patients underwent dPET (Vereos, Philips Healthcare) and cPET (Ingenuity TF, Philips Healthcare) imaging in a randomized order. We used HR-reconstructions (2x2x2 mm3 voxels) for both scanners and determined SUVmax, SUVmean, lesion-to-background ratio (LBR), metabolic tumor volume (MTV) and lesion diameter in up to 5 FDG-positive lesions per patient. Furthermore, we counted the number of visible and measurable lesions on each PET scan. Two nuclear medicine specialists blindly determined the Tumor Node Metastasis (TNM) score from both image sets in 30 patients referred for initial staging. For all 66 patients, these specialists separately and blindly evaluated image quality (4-point scale) and determined the scan preference. Results: We included 238 lesions that were visible and measurable on both PET scans. We found 37 additional lesions on dPET in 27 patients (41%), which were unmeasurable (n = 14) or invisible (n = 23) on cPET. SUVmean, SUVmax, LBR and MTV on cPET were 5.2±3.9 (mean±SD), 6.9±5.6, 5.0±3.6 and 2991±13251 mm3, respectively. On dPET SUVmean, SUVmax and LBR increased 24%, 23% and 27%, respectively (p<0.001) while MTV decreased 13% (p<0.001) compared to cPET. Visual analysis showed TNM upstaging with dPET in 13% of the patients (4/30). dPET images also scored higher in image quality (P = 0.003) and were visually preferred in the majority of cases (65%). Conclusion: Digital PET improved the detection of small lesions, upstaged the disease and images were visually preferred as compared to high-resolution conventional PET. More studies are necessary to confirm the superior diagnostic performance of digital PET.




io

Quantification of PD-L1 expression with [18F]BMS-986192 PET/CT in patients with advanced stage non-small-cell lung cancer

The aim of this work was to quantify the uptake of [18F]BMS-986192, a PD-L1 adnectin PET tracer, in patients with non-small-cell lung cancer (NSCLC). To this end, plasma input kinetic modeling of dynamic tumor uptake data with online arterial blood sampling was performed. In addition, the accuracy of simplified uptake metrics such as standardized uptake value (SUV) was investigated. Methods: Data from a study with [18F]BMS-986192 in patients with advanced stage NSCLC eligible for nivolumab treatment were used if a dynamic scan was available and lesions were present in the field of view of the dynamic scan. After injection of [18F]BMS-986192, a 60-minutes dynamic PET-CT scan was started, followed by a 30-min whole body PET-CT scan. Continuous arterial and discrete arterial and venous blood sampling were performed to determine a plasma input function. Tumor time activity curves were fitted by several plasma input kinetic models. Simplified uptake parameters included tumor to blood ratio as well as several SUV measures. Results: Twenty two tumors in nine patients were analyzed. The arterial plasma input single-tissue reversible compartment model with fitted blood volume fraction seems to be the most preferred model as it best fitted 11 out of 18 tumor time activity curves. The distribution volume VT ranged from 0.4 to 4.8 mL·cm-3. Similar values were obtained with an image derived input function. From the simplified measures, SUV normalized for body weight (SUVBW) at 50 and 67 minutes post injection correlated best with VT, with an R2 > 0.9. Conclusion: A single tissue reversible model can be used for the quantification of tumor uptake of the PD-L1 PET tracer [18F]BMS-986192. SUVBW at 60 minutes post injection, normalized for body weight, is an accurate simplified parameter for uptake assessment of baseline studies. In order to assess its predictive value for response evaluation during PD-(L)1 immune checkpoint inhibition further validation of SUV against VT based on an image derived input function is recommended.




io

Clinical Translation of a 68Ga-labeled Integrin {alpha}v{beta}6-targeting Cyclic Radiotracer for PET Imaging of Pancreatic Cancer

The overexpression of integrin αvβ6 in pancreatic cancer makes it a promising target for noninvasive positron emission tomography (PET) imaging. However, currently, most integrin αvβ6-targeting radiotracers are based on linear peptides, which are quickly degraded in the serum by proteinases. Herein, we aimed to develop and assess a 68Ga-labeled integrin αvβ6-targeting cyclic peptide (68Ga-cycratide) for PET imaging of pancreatic cancer. Methods: 68Ga-cycratide was prepared, and its PET imaging profile was compared with that of the linear peptide (68Ga-linear-pep) in an integrin αvβ6-positive BxPC-3 human pancreatic cancer mouse model. Five healthy volunteers (two women and three men) underwent whole-body PET/CT imaging after injection of 68Ga-cycratide, and biodistribution and dosimetry calculations were determined. PET/CT imaging of two patients was performed to investigate the potential role of 68Ga-cycratide in pancreatic cancer diagnosis and treatment monitoring. Results: 68Ga-cycratide exhibited significantly higher tumor uptake than did 68Ga-linear-pep in BxPC-3 tumor-bearing mice, owing—at least in part—to markedly improved in vivo stability. 68Ga-cycratide could sensitively detect the pancreatic cancer lesions in an orthotopic mouse model and was well tolerated in all healthy volunteers. Preliminary PET/CT imaging in patients with pancreatic cancer demonstrated that 68Ga-cycratide was comparable to 18F-fludeoxyglucose for diagnostic imaging and post-surgery tumor relapse monitoring. Conclusion: 68Ga-cycratide is an integrin αvβ6-specific PET radiotracer with favorable pharmacokinetics and dosimetry profile. 68Ga-cycratide is expected to provide an effective noninvasive PET strategy for pancreatic cancer lesion detection and therapy response monitoring.




io

Development and evaluation of interleukin-2 derived radiotracers for PET imaging of T-cells in mice

Recently, N-(4-18F-fluorobenzoyl)-interleukin-2 (18F-FB-IL2) was introduced as PET tracer for T-cell imaging. However, production is complex and time-consuming. Therefore, we developed two radiolabeled interleukin-2 (IL-2) variants, namely aluminum 18F-fluoride-(restrained complexing agent)-IL-2 (18F-AlF-RESCA-IL2) and 68Ga-gallium-(1,4,7-triazacyclononane-4,7-diacetic acid-1-glutaric acid)-IL-2 (68Ga-Ga-NODAGA-IL2) and compared their in-vitro and in-vivo characteristics with 18F-FB-IL2. Methods: Radiolabeling of 18F-AlF-RESCA-IL2 and 68Ga-Ga-NODAGA-IL2 was optimized and stability was evaluated in human serum. Receptor binding was studied with activated human peripheral blood mononuclear cells (hPBMCs). Ex-vivo tracer biodistribution in immunocompetent BALB/cOlaHsd (BALB/c) mice was performed at 15, 60 and 90 min after tracer injection. In-vivo binding characteristics were studied in severe combined immune-deficient (SCID) mice inoculated with activated hPBMCs in Matrigel. Tracer was injected 15 min after hPBMCs inoculation and a 60-min dynamic PET scan was acquired, followed by ex-vivo biodistribution studies. Specific uptake was determined by co-injection of tracer with unlabeled IL2 and by evaluating uptake in a control group inoculated with Matrigel only. Results: 68Ga-Ga-NODAGA-IL2 and 18F-AlF-RESCA-IL2 were produced with radiochemical purity >95% and radiochemical yield of 13.1±4.7% and 2.4±1.6% within 60 and 90 min, respectively. Both tracers were stable in serum, with >90% being intact tracer after 1h. In-vitro, both tracers displayed preferential binding to activated hPBMCs. Ex-vivo biodistribution studies in BALB/c mice showed higher uptake of 18F-AlF-RESCA-IL2 than 18F-FB-IL2 in liver, kidney, spleen, bone and bone marrow. 68Ga-Ga-NODAGA-IL2 uptake in liver and kidney was higher than 18F-FB-IL2 uptake. In-vivo, all tracers revealed uptake in activated hPBMCs in SCID mice. Low uptake was seen after a blocking dose of IL2 or in the Matrigel control group. In addition, 18F-AlF-RESCA-IL2 yielded highest contrast PET images of target lymph nodes. Conclusion: Production of 18F-AlF-RESCA-IL2 and 68Ga-Ga-NODAGA-IL2 is simpler and faster than 18F-FB-IL2. Both tracers showed good in-vitro and in-vivo characteristics with high uptake in lymphoid tissue and hPBMC xenografts.




io

High Resolution Depth-Encoding PET Detector Module with Prismatoid Light Guide Array

Depth-encoding detectors with single-ended readout provide a practical, cost-effective approach for constructing high resolution and high sensitivity PET scanners. However, the current iteration of such detectors utilizes a uniform glass light guide to achieve depth-encoding, resulting in non-uniform performance throughout the detector array due to suboptimal intercrystal light sharing. We introduce Prism-PET, a single-ended readout PET detector module with a segmented light guide composed of an array of prismatoids that introduces enhanced, deterministic light sharing. Methods: High resolution PET detector modules were fabricated with single-ended readout of polished multicrystal lutetium yttrium orthosilicate (LYSO) scintillator arrays directly coupled 4-to-1 and 9-to-1 to arrays of 3.2 x 3.2 mm2 silicon photomultiplier pixels. Each scintillator array was coupled at the non-readout side to a light guide (one 4-to-1 module with a uniform glass light guide, one 4-to-1 Prism-PET module and one 9-to-1 Prism-PET module) to introduce intercrystal light sharing, which closely mimics the behavior of dual-ended readout with the additional benefit of improved crystal identification. Flood histogram data was acquired using a 3 MBq Na-22 source to characterize crystal identification and energy resolution. Lead collimation was used to acquire data at specific depths to determine depth-of-interaction (DOI) resolution. Results: The flood histogram measurements showed excellent and uniform crystal separation throughout the Prism-PET modules while the uniform glass light guide module had performance degradation at the edges and corners. A DOI resolution of 5.0 mm full width at half maximum (FWHM) and energy resolution of 13% were obtained in the uniform glass light guide module. By comparison, the 4-to-1 coupled Prism-PET module achieved 2.5 mm FWHM DOI resolution and 9% energy resolution. Conclusion: PET scanners based on our Prism-PET modules with segmented prismatoid light guide arrays can achieve high and uniform spatial resolution (9-to-1 coupling with ~ 1 mm crystals), high sensitivity, good energy and timing resolutions (using polished crystals and after applying DOI-correction), and compact size (depth-encoding eliminates parallax error and permits smaller ring-diameter).




io

Digital Solid-State SPECT/CT Quantitation of Absolute 177Lu-Radiotracer Concentration: In Vivo/In Vitro Validation

The accuracy of lutetium-177 (177Lu) radiotracer concentration measurements using quantitative clinical software was determined by comparing in vivo results for a digital solid-state cadmium-zinc-telluride SPECT/CT (single photon emission computed tomography / x-ray computed tomography) system to in vitro sampling. First, image acquisition parameters were assessed for an International Electrotechnical Commission (IEC) body phantom emulating clinical count rates loaded with a "lung" insert and 6 hot spheres with a 12:1 target-to-background ratio of 177Lu solution. Then, the data of 28 whole-body SPECT/CT scans of 7 patients who underwent 177Lu prostate membrane antigen (177Lu-PSMA) radioligand therapy was retrospectively analyzed. Three users analyzed SPECT/CT images for in vivo urinary bladder radiotracer uptake using quantitative software (Q.Metrix, GE Healthcare). In vitro radiopharmaceutical concentrations were calculated using urine sampling obtained immediately after each scan, scaled to standardized uptake values (SUVs). Any in vivo/in vitro identity relations were determined by linear regression (ideally slope=1, intercept=0), within a 95 % confidence interval (CI). Phantom results demonstrated lower quantitative error for acquisitions using the 113 keV 177Lu energy peak rather than including the 208 keV peak, given that only low-energy collimation was available in this camera configuration. In the clinical study, 24 in vivo/in vitro pairs were eligible for further analysis, having rejected 4 as outliers (via Cook’s distance calculations). All linear regressions (R2 ≥ 0.92, P<0.0001) provided identity in vivo/in vitro relations (95 % CI), with SUV averages from all users giving a slope of 1.03±0.09, an intercept of –0.25±0.64 g/mL, and an average residual difference of 20.4 %. Acquiring with the lower energy 177Lu energy peak, solid-state SPECT/CT imaging provides an accuracy to within ~20 % for in vivo urinary bladder radiotracer concentrations. This non-invasive in vivo quantitation method can potentially improve diagnosis, improve patient management and treatment response assessment, and provide data essential to 177Lu dosimetry.




io

64Cu-DOTATATE PET/CT and prediction of overall and progression-free survival in patients with neuroendocrine neoplasms

Overexpression of somatostatin receptors in patients with neuroendocrine neoplasms (NEN) is utilized for both diagnosis and treatment. Receptor density may reflect tumor differentiation and thus be associated with prognosis. Non-invasive visualization and quantification of somatostatin receptor density is possible by somatostatin receptor imaging (SRI) using positron emission tomography (PET). Recently, we introduced 64Cu-DOTATATE for SRI and we hypothesized that uptake of this tracer could be associated with overall (OS) and progression-free survival (PFS). Methods: We evaluated patients with NEN that had a 64Cu-DOTATATE PET/CT SRI performed in two prospective studies. Tracer uptake was determined as the maximal standardized uptake value (SUVmax) for each patient. Kaplan-Meier analysis with log-rank was used to determine the predictive value of 64Cu-DOTATATE SUVmax for OS and PFS. Specificity, sensitivity and accuracy was calculated for prediction of outcome at 24 months after 64Cu-DOTATATE PET/CT. Results: A total of 128 patients with NEN were included and followed for a median of 73 (1-112) months. During follow-up, 112 experienced disease progression and 69 patients died. The optimal cutoff for 64Cu-DOTATATE SUVmax was 43.3 for prediction of PFS with a hazard ratio of 0.56 (95% CI: 0.38-0.84) for patients with SUVmax > 43.3. However, no significant cutoff was found for prediction of OS. In multiple Cox regression adjusted for age, sex, primary tumor site and tumor grade, the SUVmax cutoff hazard ratio was 0.50 (0.32-0.77) for PFS. The accuracy was moderate for predicting PFS (57%) at 24 months after 64Cu-DOTATATE PET/CT. Conclusion: In this first study to report the association of 64Cu-DOTATATE PET/CT and outcome in patients with NEN, tumor somatostatin receptor density visualized with 64Cu-DOTATATE PET/CT was prognostic for PFS but not OS. However, the accuracy of prediction of PFS at 24 months after 64Cu-DOTATATE PET/CT SRI was moderate limiting the value on an individual patient basis.




io

Early prostate-specific antigen changes and clinical outcome following 177Lu-PSMA radionuclide treatment in patients with metastatic castration-resistant prostate cancer

Background: Prostate-specific antigen (PSA) is widely used to monitor treatment response in patients with metastatic castration-resistant prostate cancer (mCRPC). However, PSA measurements are considered only after 12 wk of treatment. We aimed to evaluate the prognostic value of early PSA changes following 177Lu-labelled prostate specific membrane antigen (LuPSMA) radionuclide treatment in mCRPC patients. Methods: Men who were treated under a compassionate access program with LuPSMA at our institution and had available PSA values at baseline, at 6 wk after treatment initiation were included in this retrospective analysis. Patients were assigned to three groups based on PSA changes: 1) response: ≥30% decline, 2) progression: ≥25% increase and 3) stable: <30% decline and <25% increase. The co-primary endpoints were overall survival and imaging-based progression-free survival. The secondary end points were PSA changes at 12 wk and PSA flare-up. Results: We identified 124 eligible patients with PSA values at 6 wk. A ≥30% decline in PSA at 6 wk was associated with longer overall survival (median 16.7 mo; 95%CI 14.4–19.0) compared with patients with stable PSA (median: 11.8 mo; 95%CI 8.6–15.1; P = 0.007) and progression (median: 6.5 mo; 95%CI 5.2–7.8; p<0.001). Patients with ≥30% decline in PSA at 6 wk also had a reduced risk of imaging-based progression compared with patients with stable PSA (HR: 0.60; 95%CI 0.38–0.94; P = 0.02), while patients with PSA progression had a higher risk of imaging-based progression compared with those showing stable PSA (HR: 3.18; 95%CI 1.95–5.21; p<0.001). The percentage changes of PSA at 6 wk and 12 wk were highly associated (r=0.90; p<0.001). 29 of 31 (94%) patients who experienced early PSA progression at 6 wk achieved biochemical progression at 12 wk. Overall, only 1 of 36 (3%) patients with PSA progression at 6 wk achieved any PSA decline at 12 wk (1% of the entire cohort). Limitations of the study included its retrospective nature and the single center experience. Conclusion: PSA changes at 6 wk after LuPSMA initiation are an early indicator of long-term clinical outcome. Patients progressing by PSA after 6 wk of treatment could benefit from a very early treatment switch decision. PSA flare-up during LuPSMA treatment is very uncommon. Prospective studies are now warranted to validate our findings and potentially inform clinicians earlier on the effectiveness of LuPSMA.




io

Kinetic modeling and test-retest reproducibility of 11C-EKAP and 11C-FEKAP, novel agonist radiotracers for PET imaging of the kappa opioid receptor in humans

The kappa opioid receptor (KOR) is implicated in various neuropsychiatric disorders. We previously evaluated an agonist tracer, 11C-GR103545, for PET imaging of KOR in humans. Although 11C-GR103545 showed high brain uptake, good binding specificity, and selectivity to KOR, it displayed slow kinetics and relatively large test-retest variability (TRV) of distribution volume (VT) estimates (15%). Therefore we set out to develop two novel KOR agonist radiotracers, 11C-EKAP and 11C-FEKAP, and in nonhuman primates, both tracers exhibited faster kinetics and comparable binding parameters to 11C-GR103545. The aim of this study was to assess their kinetic and binding properties in humans. Methods: Six healthy subjects underwent 120-min test-retest PET scans with both 11C-EKAP and 11C-FEKAP. Metabolite-corrected arterial input functions were measured. Regional time-activity curves (TACs) were generated for 14 regions of interest. One- and two-tissue compartment models (1TC, 2TC) and the multilinear analysis-1 (MA1) method were applied to the regional TACs to calculate VT. Time-stability of VT values and test-retest reproducibility were evaluated. Levels of specific binding, as measured by the non-displaceable binding potential (BPND) for the three tracers (11C-EKAP, 11C-FEKAP and 11C-GR103545), were compared using a graphical method. Results: For both tracers, regional TACs were fitted well with the 2TC model and MA1 method (t*=20min), but not with the 1TC model. Given unreliably estimated parameters in several fits with the 2TC model and a good match between VT values from MA1 and 2TC, MA1 was chosen as the appropriate model for both tracers. Mean MA1 VT values were highest for 11C-GR103545, followed by 11C-EKAP, then 11C-FEKAP. Minimum scan time for stable VT measurement was 90 and 110min for 11C-EKAP and 11C-FEKAP, respectively, compared with 140min for 11C-GR103545. The mean absolute TRV in MA1 VT estimates was 7% and 18% for 11C-EKAP and 11C-FEKAP, respectively. BPND levels were similar for 11C-FEKAP and 11C-GR103545, but ~25% lower for 11C-EKAP. Conclusion: The two novel KOR agonist tracers showed faster tissue kinetics than 11C-GR103545. Even with slightly lower BPND, 11C-EKAP is judged to be a better tracer for imaging and quantification of KOR in humans, based on the shorter minimum scan time and excellent test-retest.




io

First-in-Human Trial of Dasatinib-Derivative Tracer for Tumor Kinase-Targeted Positron Emission Tomography

We developed a first-of-kind dasatinib-derivative imaging agent, 18F-SKI-249380 (18F-SKI), and validated its use for noninvasive in vivo tyrosine kinase-targeted tumor detection in preclinical models. In this study, we assess the feasibility of using 18F-SKI for PET imaging in patients with malignancies. Methods: Five patients with a prior diagnosis of breast cancer, renal cell cancer, or leukemia underwent whole-body PET/CT imaging 90 min post-injection of 18F-SKI (mean: 241.24 ± 116.36 MBq) as part of a prospective study. In addition, patients underwent either a 30-min dynamic scan of the upper abdomen including, at least partly, cardiac left ventricle, liver, spleen, and kidney (n = 2) or three 10-min whole-body PET/CT scans (n = 3) immediately post-injection and blood-based radioactivity measurements to determine the time course of tracer distribution and facilitate radiation dose estimates. A subset of three patients had a delayed whole-body PET/CT scan at 180 min. Biodistribution, dosimetry, and tumor uptake were quantified. Absorbed doses were calculated using OLINDA/EXM 1.0. Results: No adverse events occurred after injection of 18F-SKI. A total of 27 tumor lesions were analyzed with median SUVpeak 1.4 (range, 0.7–2.3) and tumor-to-blood ratios of 1.6 (range, 0.8–2.5) at 90 min post-injection. Intratumoral drug concentrations calculated for four reference lesions ranged from 0.03–0.07 nM. In all reference lesions, constant tracer accumulation was observed between 30–90 min post-injection. Blood radio-assay indicated that radiotracer clearance from blood and plasma was initially rapid (blood half-time 1.31 ± 0.81 min, plasma 1.07 ± 0.66 min; n = 4), followed variably by either a prolonged terminal phase (blood half-time 285 ± 148.49 min, plasma 240 ± 84.85 min; n = 2) or a small rise to plateau (n = 2). Like dasatinib, 18F-SKI underwent extensive metabolism post-administration, as evidenced by metabolite analysis. Radioactivity was predominantly cleared via the hepatobiliary route. The highest absorbed dose estimates (mGy/MBq) in normal tissues were to the right colon (0.167 ± 0.04) and small intestine (0.153 ± 0.03). The effective dose was 0.0258 (SD 0.0034) mSv/MBq. Conclusion: 18F-SKI demonstrated significant tumor uptake, distinct image contrast despite low injected doses, and rapid clearance from blood.




io

Biokinetics of Radiolabeled Monoclonal Antibody BC8: Differences in Biodistribution and Dosimetry among Hematologic Malignancies.

We reviewed 111In-DOTA-anti-CD45 antibody (BC8) imaging and bone marrow biopsy measurements to ascertain biodistribution and biokinetics of the radiolabeled antibody and to investigate differences based on type of hematologic malignancy. Methods: Serial whole-body scintigraphic images (4 time-points) were obtained after infusion of the 111In-DOTA-BC8 (176-406 MBq) in 52 adult patients with hematologic malignancies (lymphoma, multiple myeloma, acute myeloid leukemia and myelodysplastic syndrome). Counts were obtained for the regions of interest for spleen, liver, kidneys, testicles (in males), and two marrow sites (acetabulum and sacrum) and correction for attenuation and background was made. Bone marrow biopsies were obtained 14-24 hours post-infusion and percent of administered activity was determined. Radiation absorbed doses were calculated. Results: Initial uptake in liver averaged 32% ± 8.4% (S.D.) of administered activity (52 patients), which cleared monoexponentially with biological half-time of 293 ± 157 hours (33 patients) or did not clear (19 patients). Initial uptake in spleen averaged 22% ± 12% and cleared with a biological half-time 271 ± 185 hours (36 patients) or longer (6 patients). Initial uptake in kidney averaged 2.4% ± 2.0% and cleared with a biological half-time of 243 ± 144 hours (27 patients) or longer (9 patients). Initial uptake in red marrow averaged 23% ± 11% and cleared with half-times of 215 ± 107 hours (43 patients) or longer (5 patients). Whole-body retention half-times averaged 198 ± 75 hours. Splenic uptake was higher in the AML/MDS group when compared to the lymphoma group (p ≤ 0.05) and to the multiple myeloma group (p ≤ 0.10). Liver represented the dose-limiting organ. For liver uptake, no significant differences were observed between the three malignancy groups. Average calculated radiation absorbed doses per unit administered activity for a therapy infusions of 90Y-DOTA-BC8 were for red marrow: 470 ± 260 cGy/MBq, liver 1100 ± 330 cGy/MBq, spleen 4120 ± 1950 cGy/MBq, total body 7520 ± 20 cGy/MBq, osteogenic cells 290 ± 200 cGy/MBq, and kidneys 240 ± 200 cGy/MBqR. Conclusion: 111In-DOTA-BC8 had long retention time in liver, spleen, kidneys, and red marrow, and the highest absorbed doses were calculated for spleen and liver. Few differences were observed by malignancy type. The exception was greater splenic uptake among leukemia/MDS group when compared to lymphoma and multiple myeloma groups.




io

Prognostic Value of 18F-FDG PET/CT in a Large Cohort of 495 Patients with Advanced Metastatic Neuroendocrine Neoplasms (NEN) Treated with Peptide Receptor Radionuclide Therapy (PRRT)

The objective of this retrospective study was to determine the role of 18F-FDG PET/CT in a large cohort of 495 patients with metastatic neuroendocrine neoplasms (NENs) who were treated with peptide receptor radionuclide therapy (PRRT) with a long-term follow-up. Methods: The 495 patients were treated with 177Lu- and/or 90Y- DOTATOC/DOTATATE PRRT between 2/2002 and 7/2018. All subjects received both 68Ga-DOTATOC/TATE/NOC and 18F-FDG PET/CT prior to treatment and were followed 3-189 months. Kaplan-Meier analysis, log-rank test (Mantel-Cox), and Cox regression analysis were performed for overall survival (OS) and progression-free survival (PFS). Results: 199 patients (40.2%) presented with pancreatic NEN, 49 with CUP (cancer of unknown primary), 139 with midgut NEN, whereas the primary tumor was present in the rectum in 20, in the lung in 38, in the stomach in 8 and other locations in 42 patients. FDG-PET/CT was positive in 382 (77.2%) patients and 113 (22.8%) were FDG-negative before PRRT, while 100% were 68Ga-DOTATOC/TATE/NOC positive. For all patients, the median PFS and OS, defined from start of PRRT, were 19.6 mo and 58.7 mo, respectively. Positive FDG predicted shorter PFS (18.5 mo vs 24.1 mo; P = 0.0015) and OS (53.2 mo vs 83.1 mo; P < 0.001) than negative FDG. Amongst the pancreatic NEN, the median OS was 52.8 mo in FDG positive and 114.3 mo in FDG negative subjects (P = 0.0006). For all patients with positive 18F-FDG uptake, and a ratio of the highest SUVmax on 68Ga-SSTR PET to the most 18F-FDG-avid tumor lesions >2, the median OS was 53.0 mo, compared to 43.4 mo in those patients with a ratio <2 (P = 0.030). For patients with no 18F-FDG uptake (complete "mismatch" imaging pattern), the median OS was 108.3 mo vs 76.9 mo for SUVmax >15.0 and ≤15.0 on 68Ga-SSTR PET/CT, respectively. Conclusion: The presence of positive lesions on 18F-FDG PET is an independent prognostic factor in patients with NEN treated with PRRT. Metabolic imaging with 18F-FDG PET/CT compliments the molecular imaging aspect of 68Ga-SSTR PET/CT for the prognosis of survival after PRRT. High SSTR expression combined with negative 18F-FDG PET/CT imaging is associated with the most favorable long-term prognosis.




io

68Ga-PSMA guided bone biopsies for molecular diagnostics in metastatic prostate cancer patients

For individual treatment decisions in patients with metastatic prostate cancer (mPC), molecular diagnostics are increasingly used. Bone metastases are frequently the only source for obtaining metastatic tumor tissue. However, the success rate of computed tomography (CT)-guided bone biopsies for molecular analyses in mPC patients is only ~40%. Positron emission tomography (PET) using Gallium-68 prostate specific membrane antigen (68Ga-PSMA) is a promising tool to improve the harvest rate of bone biopsies for molecular analyses. Aim of this study was to determine the success rate of 68Ga-PSMA guided bone biopsies for molecular diagnostics in mPC patients. Methods: Within a prospective multicenter whole-genome sequencing trial (NCT01855477), 69 mPC patients underwent 68Ga-PSMA PET/CT prior to bone biopsy. Primary endpoint was success rate (tumor percentage ≥30%) of 68Ga-PSMA guided bone biopsies. At biopsy sites, 68Ga-PSMA uptake was quantified using rigid body image registration of 68Ga-PSMA PET/CT and interventional CT. Actionable somatic alterations were identified. Results: Success rate of 68Ga-PSMA guided biopsies for molecular analyses was 70%. At biopsy sites categorized as positive, inconclusive, or negative for 68Ga-PSMA uptake, 70%, 64%, and 36% of biopsies were tumor positive (≥30%), respectively (P = 0.0610). In tumor positive biopsies, 68Ga-PSMA uptake was significantly higher (P = 0.008), whereas radiodensity was significantly lower (P = 0.006). With an area under the curve of 0.84 and 0.70, both 68Ga-PSMA uptake (maximum standardized uptake value) and radiodensity (mean Hounsfield Units) were strong predictors for a positive biopsy. Actionable somatic alterations were detected in 73% of the sequenced biopsies. Conclusion: In patients with mPC, 68Ga-PSMA PET/CT improves the success rate of CT-guided bone biopsies for molecular analyses, thereby identifying actionable somatic alterations in more patients. Therefore, 68Ga-PSMA PET/CT may be considered for guidance of bone biopsies in both clinical practice and clinical trials.




io

Neuroendocrine Differentiation and Response toPSMA-Targeted Radioligand Therapy in Advanced Metastatic Castration-Resistant Prostate Cancer: a Single-Center Retrospective Study

Introduction: Neuroendocrine differentiation is associated with treatment failure and poor outcome in metastatic castration-resistant prostate cancer (mCRPC). We investigated the effect of circulating neuroendocrine biomarkers on the efficacy of PSMA-targeted radioligand therapy (RLT). Methods: Neuroendocrine biomarker profiles (progastrin-releasing peptide, neuron-specific enolase, and chromogranin-A) were analyzed in 50 patients commencing 177Lu-PSMA-617 RLT. The primary endpoint was PSA response in relation to baseline neuroendocrine marker profiles. Additional endpoints included progression-free survival. Tumor uptake on post-therapeutic scans, a known predictive marker for response, was used as control-variable. Results: Neuroendocrine biomarker profiles were abnormal in the majority of patients. Neuroendocrine biomarker levels did not predict treatment failure or early progression (P ≥ 0.13). By contrast, intense PSMA-ligand uptake in metastases predicted both treatment response (P = 0.0030) and reduced risk of early progression (P = 0.0111). Conclusion: Neuroendocrine marker profiles do not predict adverse outcome of RLT. By contrast, high ligand uptake was confirmed to be crucial for achieving tumor-response.




io

Defining hyper-progressive disease using tumor growth rate: what are limitations and shortcuts?




io

The optimal imaging window for dysplastic colorectal polyp detection using c-Met targeted fluorescence molecular endoscopy

Rationale: Fluorescence molecular endoscopy (FME) is an emerging technique that has the potential to improve the 22% colorectal polyp detection miss-rate. We determined the optimal dose-to-imaging interval and safety of FME using EMI-137, a c-Met targeted fluorescent peptide, in a population at high-risk for colorectal cancer. Methods: We performed in vivo FME and quantification of fluorescence by multi-diameter single-fiber reflectance, single-fiber fluorescence spectroscopy in 15 patients with a dysplastic colorectal adenoma. EMI-137 was intravenously administered (0.13mg/kg) at a one-, two- or three-hour dose-to-imaging interval (N = 3 patients per cohort). Two cohorts were expanded to six patients based on target-to-background ratios (TBR). Fluorescence was correlated to histopathology and c-Met expression. EMI-137 binding specificity was assessed by fluorescence microscopy and in vitro experiments. Results: FME using EMI-137 appeared to be safe and well tolerated. All dose-to-imaging intervals showed significantly increased fluorescence in the colorectal lesions compared to surrounding tissue, with a TBR of 1.53, 1.66 and 1.74 respectively (mean intrinsic fluorescence (Q·μfa,x) = 0.035 vs. 0.023mm-1, P<0.0003; 0.034 vs. 0.021mm-1, P<0.0001; 0.033 vs. 0.019mm-1, P<0.0001). Fluorescence correlated to histopathology on a macroscopic and microscopic level, with significant c-Met overexpression in dysplastic mucosa. In vitro, a dose-dependent specific binding was confirmed. Conclusion: FME using EMI-137 appeared to be safe and feasible within a one-to-three hour dose-to-imaging interval. No clinically significant differences were observed between the cohorts, although a one-hour dose-to-imaging interval was preferred from a clinical perspective. Future studies will investigate EMI-137 for improved colorectal polyp detection during screening colonoscopies.




io

11C-PABA as a Novel PET Radiotracer for Functional Renal Imaging: Preclinical and First-in-Human Studies

para-Aminobenzoic acid (PABA) has been previously used as an exogenous marker to verify completion of 24-hour urine sampling. Therefore, we hypothesized that radiolabeled PABA with 11C could allow high-quality dynamic PET of the kidneys while reducing the radiation exposure due to its short biological and physical half-lives. We evaluated if 11C-PABA could visualize renal anatomy and quantify function in healthy rats, rabbits, and first-in-human studies in healthy volunteers. Methods: Healthy rats and rabbits were injected with 11C-PABA intravenously. Subsequently, a dynamic PET was performed, followed by post-mortem tissue biodistribution studies. 11C-PABA PET was directly compared with the current standard, 99mTc-MAG3 in rats. Three healthy human subjects also underwent dynamic PET after intravenous injection of 11C-PABA. Results: In healthy rats and rabbits, dynamic PET demonstrated a rapid accumulation of 11C-PABA in the renal cortex, followed by rapid excretion through the pelvicalyceal system. In humans, 11C-PABA PET was safe and well tolerated. There were no adverse or clinically detectable pharmacologic effects in any subject. The cortex was delineated on PET, and the activity gradually transited to the medulla and then renal pelvis with high spatiotemporal resolution. Conclusion: 11C-PABA demonstrated fast renal excretion with very low background signal in animals and humans. These results suggest that 11C-PABA could be used as a novel radiotracer for functional renal imaging, providing high-quality spatiotemporal images with low radiation exposure.




io

18F-DCFPyL PET/CT in Patients with Subclinical Recurrence of Prostate Cancer: Effect of Lesion Size, Smooth Filter and Partial Volume Correction on Prostate Cancer Molecular Imaging Standardized Evaluation (PROMISE) criteria

Purpose: To determine the effect of smooth filter and partial volume correction (PVC) method on measured prostate-specific membrane antigen (PSMA) activity in small metastatic lesions and to determine the impact of these changes on the molecular imaging (mi) PSMA scoring. Materials & Methods: Men with biochemical recurrence of prostate cancer with negative CT and bone scintigraphy were referred for 18F-DCFPyL PET/CT. Examinations were performed on one of 2 PET/CT scanners (GE Discovery 610 or Siemens mCT40). All suspected tumor sites were manually contoured on co-registered CT and PET images, and each was assigned a miPSMA score as per the PROMISE criteria. The PVC factors were calculated for every lesion using the anatomical CT and then applied to the unsmoothed PET images. The miPSMA scores, with and without the corrections, were compared, and a simplified "rule of thumb" (RoT) correction factor (CF) was derived for lesions at various sizes (<4mm, 4-7mm, 7-9mm, 9-12mm). This was then applied to the original dataset and miPSMA scores obtained using the RoT CF were compared to those found using the actual corrections. Results: There were 75 men (median age, 69 years; median serum PSA of 3.69 ug/L) with 232 metastatic nodes < 12 mm in diameter (mean lesion volume of 313.5 ± 309.6 mm3). Mean SUVmax before and after correction was 11.0 ± 9.3 and 28.5 ± 22.8, respectively (p<0.00001). The mean CF for lesions <4mm (n = 22), 4-7mm (n = 140), 7-9mm (n = 50), 9-12 mm (n = 20) was 4 (range: 2.5-6.4), 2.8 (range: 1.6-4.9), 2.3 (range: 1.6-3.3) and 1.8 (range 1.4-2.4), respectively. Overall miPSMA scores were concordant between the corrected dataset and RoT in 205/232 lesions (88.4%). Conclusion: There is a significant effect of smooth filter and partial volume correction on measured PSMA activity in small nodal metastases, impacting the miPSMA score.




io

Benefit of improved performance with state-of-the art digital PET/CT for lesion detection in oncology

Latest digital whole-body PET scanners provide a combination of higher sensitivity and improved spatial and timing resolution. We performed a lesion detectability study on two generations of Siemens Biograph PET/CT scanners, the mCT and Vision, to study the impact of improved physical performance on clinical performance. Our hypothesis is that the improved performance of the Vision will result in improved lesion detectability, allowing shorter imaging times or equivalently, lower injected dose. Methods: Data were acquired with the Society of Nuclear Medicine and Molecular Imaging Clinical Trials Network torso phantom combined with a 20-cm diameter cylindrical phantom. Spherical lesions were emulated by acquiring spheres-in-air data, and combining it with the phantom data to generate combined datasets with embedded lesions of known contrast. Two sphere sizes and uptakes were used: 9.89 mm diameter spheres with 6:1 (lung) and 3:1 (cylinder) and 4.95 mm diameter spheres with 9.6:1 (lung) and 4.5:1 (cylinder) local activity concentration uptakes. Standard image reconstruction was performed: ordinary Poisson ordered subsets expectation maximization algorithm with point spread function and time-of-flight modeling and post-reconstruction smoothing with a 5 mm Gaussian filter. The Vision images were also generated without any post-reconstruction smoothing. Generalized scan statistics methodology was used to estimate the area under the localization receiver operating characteristic curve (ALROC). Results: Higher sensitivity and improved TOF performance of Vision leads to reduced contrast in the background noise nodule distribution. Measured lesion contrast is also higher on the Vision due to its improved spatial resolution. Hence, the ALROC values are noticeably higher for the Vision relative to the mCT. Conclusion: Improved overall performance of the Vision provides a factor of 4-6 reduction in imaging time (or injected dose) over the mCT when using the ALROC metric for lesions >9.89 mm in diameter. Smaller lesions are barely detected in the mCT, leading to even higher ALROC gains with the Vision. Improved spatial resolution of the Vision also leads to a higher measured contrast that is closer to the real uptake, implying improved quantification. Post-reconstruction smoothing, however, reduces this improvement in measured contrast, thereby reducing the ALROC values for small, high uptake lesions.




io

A Prospective, Comparative Study of Planar and Single-photon Emission Computed Tomography Ventilation/Perfusion Imaging for Chronic Thromboembolic Pulmonary Hypertension

Objectives: The study compared the diagnostic performance of Planar Ventilation/perfusion (V/Q) and V/Q Single-photon computed tomography (SPECT), and determined whether combining perfusion scanning with low-dose computed tomography (Q-LDCT) may be equally effective in a prospective study of patients with chronic thromboembolic pulmonary hypertension (CTEPH) patients. Background: V/Q scanning is recommended for excluding CTEPH during the diagnosis of pulmonary hypertension (PH). However, Planar V/Q and V/Q SPECT techniques have yet to be compared in patients with CTEPH. Methods: Patients with suspected PH were eligible for the study. PH attributable to left heart disease or lung disease was excluded, and patients whose PH was confirmed by right heart catheterization and who completed Planar V/Q, V/Q-SPECT, Q-LDCT, and pulmonary angiography were included. V/Q images were interpreted and patients were diagnosed as instructed by the 2009 EANM guidelines, and pulmonary angiography analyses were used as a reference standard. Results: A total of 208 patients completed the study, including 69 with CTEPH confirmed by pulmonary angiography. Planar V/Q, V/Q-SPECT, and Q-LDCT were all highly effective for diagnosing CTEPH, with no significant differences in sensitivity or specificity observed among the three techniques (Planar V/Q [sensitivity/specificity]: 94.20%/92.81%; V/Q-SPECT: 97.10%/91.37%, Q-LCDT: 95.65%/90.65%). However, V/Q-SPECT was significantly more sensitive (V/Q-SPECT: 79.21%; Planar V/Q: 75.84%, P = 0.012; Q-LDCT: 74.91%, p<0.001), and Planar V/Q was significantly more specific (Planar V/Q: 54.14%; V/Q-SPECT 46.05%, p<0.001; Q-LDCT: 46.05%, P = 0.001) than the other two techniques for identifying perfusion defects in individual lung segments. Conclusion: Both Planar V/Q and V/Q-SPECT were highly effective for diagnosing CTEPH, and Q-LDCT may be a reliable alternative method for patients who are unsuitable for ventilation imaging.