imaging

Imaging Responses to Immunotherapy with Novel PET Tracers




imaging

In Vivo Imaging of Venous Thrombus and Pulmonary Embolism Using Novel Murine Venous Thromboembolism Model

This work established a new murine venous thromboembolism (VTE) model. This model has multiple novel features representing clinical VTE that include the following: 1) deep venous thrombosis (DVT) was formed and extended in the long axis of femoral/saphenous vein; 2) thrombus was formed in a venous valve pocket; 3) deligation of suture-induced spontaneous pulmonary emboli of fibrin-rich DVT; and 4) cardiac motion-free femoral/saphenous vein allowed high-resolution intravital microscopic imaging of fibrin-rich DVT. This new model requires only commercially available epifluorescence microscopy. Therefore, this model has significant potential for better understanding of VTE pathophysiology.




imaging

Efficacy of Affibody-Based Ultrasound Molecular Imaging of Vascular B7-H3 for Breast Cancer Detection

Purpose:

Human B7-H3 (hB7-H3) is a promising molecular imaging target differentially expressed on the neovasculature of breast cancer and has been validated for preclinical ultrasound (US) imaging with anti–B7-H3-antibody-functionalized microbubbles (MB). However, smaller ligands such as affibodies (ABY) are more suitable for the design of clinical-grade targeted MB.

Experimental Design:

Binding of ABYB7-H3 was confirmed with soluble and cell-surface B7-H3 by flow cytometry. MB were functionalized with ABYB7-H3 or anti–B7-H3-antibody (AbB7-H3). Control and targeted MB were tested for binding to hB7-H3–expressing cells (MS1hB7-H3) under shear stress conditions. US imaging was performed with MBABY-B7-H3 in an orthotopic mouse model of human MDA-MB-231 coimplanted with MS1hB7-H3 or control MS1WT cells and a transgenic mouse model of breast cancer development.

Results:

ABYB7-H3 specifically binds to MS1hB7-H3 and murine-B7-H3–expressing monocytes. MBABY-B7-H3 (8.5 ± 1.4 MB/cell) and MBAb-B7-H3 (9.8 ± 1.3 MB/cell) showed significantly higher (P < 0.0001) binding to the MS1hB7-H3 cells compared with control MBNon-targeted (0.5 ± 0.1 MB/cell) under shear stress conditions. In vivo, MBABY-B7-H3 produced significantly higher (P < 0.04) imaging signal in orthotopic tumors coengrafted with MS1hB7-H3 (8.4 ± 3.3 a.u.) compared with tumors with MS1WT cells (1.4 ± 1.0 a.u.). In the transgenic mouse tumors, MBABY-B7-H3 (9.6 ± 2.0 a.u.) produced higher (P < 0.0002) imaging signal compared with MBNon-targeted (1.3 ± 0.3 a.u.), whereas MBABY-B7-H3 signal in normal mammary glands and tumors with B7-H3 blocking significantly reduced (P < 0.02) imaging signal.

Conclusions:

MBABY-B7-H3 enhances B7-H3 molecular signal in breast tumors, improving cancer detection, while offering the advantages of a small size ligand and easier production for clinical imaging.




imaging

Assessment of Apparent Internal Carotid Tandem Occlusion on High-Resolution Vessel Wall Imaging: Comparison with Digital Subtraction Angiography [EXTRACRANIAL VASCULAR]

BACKGROUND AND PURPOSE:

Not all tandem occlusions diagnosed on traditional vascular imaging modalities, such as MRA, represent actual complete ICA occlusion. This study aimed to explore the utility of high-resolution vessel wall imaging in identifying true ICA tandem occlusions and screening patients for their suitability for endovascular recanalization.

MATERIALS AND METHODS:

Patients with no signal in the ICA on MRA were retrospectively reviewed. Two neuroradiologists independently reviewed their high-resolution vessel wall images to assess whether there were true tandem occlusions and categorized all cases into intracranial ICA occlusion, extracranial ICA occlusion, tandem occlusion, or near-occlusion. DSA classified patient images into the same 4 categories, which were used as the comparison with high-resolution vessel wall imaging. The suitability for recanalization of occluded vessels was evaluated on high-resolution vessel wall imaging compared with DSA.

RESULTS:

Forty-five patients with no ICA signal on MRA who had available high-resolution vessel wall imaging and DSA images were included. Among the 34 patients (34/45, 75.6%) with tandem occlusions on DSA, 18 cases also showed tandem occlusions on high-resolution vessel wall imaging. The remaining 16 patients, intracranial ICA, extracranial ICA occlusions and near-occlusions were found in 2, 6, and 8 patients, respectively, on the basis of high-resolution vessel wall imaging. A total of 20 cases (20/45, 44.4%) were considered suitable for recanalization on the basis of both DSA and high-resolution vessel wall imaging. Among the 25 patients deemed unsuitable for recanalization by DSA, 11 were deemed suitable for recanalization by high-resolution vessel wall imaging.

CONCLUSIONS:

High-resolution vessel wall imaging could allow identification of true ICA tandem occlusion in patients with an absence of signal on MRA. Findings on high-resolution vessel wall imaging can be used to screen more suitable candidates for recanalization therapy.




imaging

MRI Vessel Wall Imaging after Intra-Arterial Treatment for Acute Ischemic Stroke [INTERVENTIONAL]

BACKGROUND AND PURPOSE:

Vessel wall imaging is increasingly performed in the diagnostic work-up of patients with ischemic stroke. The aim of this study was to compare vessel wall enhancement after intra-arterial thrombosuction with that in patients not treated with thrombosuction.

MATERIALS AND METHODS:

From 2009 to 2017, forty-nine patients with an ischemic stroke underwent 7T MR imaging within 3 months after symptom onset as part of a prospective intracranial vessel wall imaging study. Fourteen of these patients underwent intra-arterial treatment using thrombosuction (intra-arterial treatment group). In the intra-arterial treatment group, vessel walls were evaluated for major vessel wall changes. All patients underwent pre- and postcontrast vessel wall imaging to assess enhancing foci of the vessel wall using coregistered subtraction images. A Wilcoxon signed rank test was performed to test for differences.

RESULTS:

In the intra-arterial treatment group, 11 of 14 patients (79%) showed vessel wall enhancement compared with 17 of 35 patients without intra-arterial treatment (49%). In the intra-arterial treatment group, more enhancing foci were detected on the ipsilateral side (n = 18.5) compared with the contralateral side (n = 3, P = .005). Enhancement was more often concentric on the ipsilateral side (n = 8) compared with contralateral side (n = 0, P = .01). No differences were found in the group without intra-arterial treatment between the number and configuration of ipsilateral and contralateral enhancing foci.

CONCLUSIONS:

Patients with intra-arterial treatment by means of thrombosuction showed more (concentric) enhancing foci of the vessel wall ipsilateral compared with contralateral to the treated artery than the patients without intra-arterial treatment, suggesting reactive changes of the vessel wall. This finding should be taken into account when assessing vessel wall MR images in patients with stroke.




imaging

Suspected Metallic Embolization Distal to Coiled Intracranial Aneurysms Detectable by Susceptibility-Weighted MR Imaging [INTERVENTIONAL]

BACKGROUND AND PURPOSE:

After endovascular coiling of intracranial aneurysms, round dark parenchymal lesions believed to be particulate metal are sometimes encountered in MR imaging studies of the brain. We used SWI to assess the frequency of such occurrences, in addition to exploring likely causes and clinical implications.

MATERIALS AND METHODS:

We reviewed 700 MR imaging studies performed between September 2018 and March 2019 at our institution as follow-up monitoring of coiled intracranial aneurysms. Any sizeable (>5 mm) rounded dark-signal lesions encountered were presumed to be metallic. The magnitudes and locations of such lesions were recorded. In patients with these lesions, pertinent procedural documentation was screened for devices used, including coils, microcatheters, microguidewires, and stents. Medical records were also examined to determine whether any related symptoms ensued.

RESULTS:

Twenty patients (2.8%) exhibited a total of 25 lesions on SWI. Diameters ranged from 5 to 11 mm (median, 8 mm). All except 2 lesions were located in brain regions downstream from aneurysms, but all lesions occupied vascular territories of vessels used to place guiding catheters. Other than the Synchro 14, which was routinely deployed, no device was regularly used in patients with SWI-detectable lesions; and none of the affected patients developed focal neurologic symptoms as a consequence.

CONCLUSIONS:

Although the origins remain unclear, distal embolization of particulate metal distal to coiled cerebral aneurysms is occasionally observed on follow-up MR imaging studies. Such lesions, however, seem to have no apparent clinical impact.




imaging

Discrimination between Glioblastoma and Solitary Brain Metastasis: Comparison of Inflow-Based Vascular-Space-Occupancy and Dynamic Susceptibility Contrast MR Imaging [FUNCTIONAL]

BACKGROUND AND PURPOSE:

Accurate differentiation between glioblastoma and solitary brain metastasis is of vital importance clinically. This study aimed to investigate the potential value of the inflow-based vascular-space-occupancy MR imaging technique, which has no need for an exogenous contrast agent, in differentiating glioblastoma and solitary brain metastasis and to compare it with DSC MR imaging.

MATERIALS AND METHODS:

Twenty patients with glioblastoma and 22 patients with solitary brain metastasis underwent inflow-based vascular-space-occupancy and DSC MR imaging with a 3T clinical scanner. Two neuroradiologists independently measured the maximum inflow-based vascular-space-occupancy–derived arteriolar CBV and DSC-derived CBV values in intratumoral regions and peritumoral T2-hyperintense regions, which were normalized to the contralateral white matter (relative arteriolar CBV and relative CBV, inflow-based vascular-space-occupancy relative arteriolar CBV, and DSC-relative CBV). The intraclass correlation coefficient, Student t test, or Mann-Whitney U test and receiver operating characteristic analysis were performed.

RESULTS:

All parameters of both regions had good or excellent interobserver reliability (0.74~0.89). In peritumoral T2-hyperintese regions, DSC-relative CBV (P < .001), inflow-based vascular-space-occupancy arteriolar CBV (P = .001), and relative arteriolar CBV (P = .005) were significantly higher in glioblastoma than in solitary brain metastasis, with areas under the curve of 0.94, 0.83, and 0.72 for discrimination, respectively. In the intratumoral region, both inflow-based vascular-space-occupancy arteriolar CBV and relative arteriolar CBV were significantly higher in glioblastoma than in solitary brain metastasis (both P < .001), with areas under the curve of 0.91 and 0.90, respectively. Intratumoral DSC-relative CBV showed no significant difference (P = .616) between the 2 groups.

CONCLUSIONS:

Inflow-based vascular-space-occupancy has the potential to discriminate glioblastoma from solitary brain metastasis, especially in the intratumoral region.




imaging

MR Thermometry in Cerebrovascular Disease: Physiologic Basis, Hemodynamic Dependence, and a New Frontier in Stroke Imaging [ADULT BRAIN]

SUMMARY:

The remarkable temperature sensitivity of the brain is widely recognized and has been studied for its role in the potentiation of ischemic and other neurologic injuries. Pyrexia frequently complicates large-vessel acute ischemic stroke and develops commonly in critically ill neurologic patients; the profound sensitivity of the brain even to minor intraischemic temperature changes, together with the discovery of brain-to-systemic as well as intracerebral temperature gradients, has thus compelled the exploration of cerebral thermoregulation and uncovered its immutable dependence on cerebral blood flow. A lack of pragmatic and noninvasive tools for spatially and temporally resolved brain thermometry has historically restricted empiric study of cerebral temperature homeostasis; however, MR thermometry (MRT) leveraging temperature-sensitive nuclear magnetic resonance phenomena is well-suited to bridging this long-standing gap. This review aims to introduce the reader to the following: 1) fundamental aspects of cerebral thermoregulation, 2) the physical basis of noninvasive MRT, and 3) the physiologic interdependence of cerebral temperature, perfusion, metabolism, and viability.




imaging

Tiny devices promise new horizon for security screening and medical imaging

Miniature devices that could be developed into safe, high-resolution imaging technology, with uses such as helping doctors identify potentially deadly cancers and treat them early, have been created.




imaging

Accurate 3D imaging of sperm cells moving at top speed could improve IVF treatments

Researchers have developed a safe and accurate 3D imaging method to identify sperm cells moving at a high speed. The new method has the potential to significantly improve IVF treatments.




imaging

Accurate 3D imaging of sperm cells moving at top speed could improve IVF treatments

Tel Aviv University (TAU) researchers have developed a safe and accurate 3D imaging method to identify sperm cells moving at a high speed. The new method has the potential to significantly improve IVF treatments.




imaging

Epson Imaging Devices Agrees to Plead Guilty and Pay $26 Million Fine for Participating in LCD Price-Fixing Conspiracy

Japanese electronics manufacturer Epson Imaging Devices Corporation (Epson) agreed to plead guilty and pay a $26 million criminal fine for its role in a conspiracy to fix prices in the sale of Thin Film Transistor-Liquid Crystal Display panels (TFT-LCD) sold to Motorola Inc.



  • OPA Press Releases

imaging

Diagnostic Imaging Group to Pay $15.5 Million for Allegedly Submitting False Claims to Federal and State Health Care Programs

Diagnostic Imaging Group (DIG) has agreed to pay a total of $15.5 million to resolve allegations that its diagnostic testing facility falsely billed federal and state health care programs for tests that were not performed or not medically necessary and by paying kickbacks to physicians.



  • OPA Press Releases

imaging

Yokogawa Acquires Fluid Imaging Technologies, a Provider of Flow Imaging Particle Analysis Solutions

Yokogawa Electric Corporation (TOKYO: 6841) announces that on April 8, it completed the acquisition of all shares of Fluid Imaging Technologies, Inc., as mutually agreed.




imaging

Live Imaging of Tumor Initiation in Zebrafish Larvae Reveals a Trophic Role for Leukocyte-Derived PGE2




imaging

PSMA PET–CT outperforms conventional imaging in high-risk prostate cancer




imaging

Brightfield multiplex immunohistochemistry with multispectral imaging




imaging

Molecular signatures of tumor progression in myxoid liposarcoma identified by <i>N</i>-glycan mass spectrometry imaging




imaging

Phase imaging with an untrained neural network




imaging

Adaptive optics two-photon microscopy enables near-diffraction-limited and functional retinal imaging in vivo




imaging

Does multiparametric imaging with <sup>18</sup>F-FDG-PET/MRI capture spatial variation in immunohistochemical cancer biomarkers in head and neck squamous cell carcinoma?




imaging

Machine intelligence lights up imaging




imaging

New imaging technique sees inside lithium batteries

A new way to see inside batteries in real time as they go through charging cycles could help prevent battery fires and increase battery lifespans




imaging

The hottest thing at CES is the FLIR thermal imaging iPhone case

Everyone in the green home improvement biz needs one of these, and they can make great cat videos on the side.




imaging

Press Release: Satellite imaging and disaster management experts gather in Colombo

Experts from across Asia gathered to discuss how the next generation of satellite based technologies could help improve disaster preparedness and response at a three-day meeting in Mount Lavinia.




imaging

Optical Imaging Technology may Aid Doctors Treat Cancer and Brain Diseases better

New technology uses optical imaging to help surgeons map out tumors in the body and help them learn how certain diseases affect activity in the brain.




imaging

New Photoacoustic Imaging Technique can Assess Kidney Quality Before Transplantation

Novel worlds' first study applies photoacoustic (PA) imaging to visualize scarring in kidneys, also called fibrosis, a common form of damage in donor's kidneys.




imaging

Accurate 3D Imaging Of Sperm Cells May Improve IVF Treatments

Safe and accurate 3D imaging method to identify sperm cells moving at a high speed has been developed. The research, a study of which was published in Science Advances on April 10, was led by Prof.




imaging

Accurate 3D Imaging Of Sperm Cells May Improve IVF Treatments

Safe and accurate 3D imaging method to identify sperm cells moving at a high speed has been developed.




imaging

Diabetic Retinopathy Treatment: Ultra-wide Field Imaging Techniques Cannot be Used Interchangeably

For the evaluation and treatment of diabetic retinopathy, clinicians often use UWF fluorescein angiography and UWF color imaging interchangeably, but




imaging

Artificial Intelligence Used For COVID-19 Lung Imaging Analysis

Health care providers are using AI in a clinical research study aimed at speeding the detection of pneumonia, a condition associated with severe COVID-19.




imaging

R&D Roundup: Sweat power, Earth imaging, testing ‘ghostdrivers’

I see far more research articles than I could possibly write up. This column collects the most interesting of those papers and advances, along with notes on why they may prove important in the world of tech and startups. This week: one step closer to self-powered on-skin electronics; people dressed as car seats; how to […]




imaging

Astronomers in Hawaii capture high resolution images ..ky imaging’ technique, probe into planet's cloud tops - Firstpost

  1. Astronomers in Hawaii capture high resolution images ..ky imaging’ technique, probe into planet's cloud tops  Firstpost
  2. Giant Planet More Astounding Than Before  NEWS9 live
  3. Scientists obtain 'lucky' image of Jupiter  BBC News
  4. New images of Jupiter captured by astronomers using `lucky technique`  WION
  5. Scientists probe Jupiter's violent storms, lightning strikes  EdexLive
  6. View Full coverage on Google News




imaging

Weather: Temperature in London: Thermal imaging photos show extreme heat on Tube

The pictures show temperatures as high as 100F (38.2C) on the 220 bus from Willesden to Wandsworth and 97F (36C) on the Northern Line today.




imaging

[ASAP] Applications for Transition-Metal Chemistry in Contrast-Enhanced Magnetic Resonance Imaging

Inorganic Chemistry
DOI: 10.1021/acs.inorgchem.0c00510




imaging

[ASAP] Tuning the Brightness and Photostability of Organic Dots for Multivalent Targeted Cancer Imaging and Surgery

ACS Nano
DOI: 10.1021/acsnano.0c01034




imaging

[ASAP] Infrared Nanoimaging of Surface Plasmons in Type-II Dirac Semimetal PtTe<sub>2</sub> Nanoribbons

ACS Nano
DOI: 10.1021/acsnano.0c02466




imaging

PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON SENSING AND IMAGING, 2018 [Electronic book].

[S.l.] : SPRINGER, 2019.




imaging

Imaging Practice and Radiation Protection in Pediatric Radiology [Electronic book] : Conventional Radiography / Michael Seidenbusch, Veronika Rösenberger, Karl Schneider.

Cham : Springer, 2020.




imaging

Imaging Brain Diseases [Electronic book] : A Radiological, Nuclear Medicine, and Neuropathological Approach / Serge Weis, Michael Sonnberger, Andreas Dunzinger, Eva Voglmayr, Martin Aichholzer, Raimund Kleiser, Peter Strasser.

Vienna : Springer, 2019.




imaging

Atlas of paediatric surgical imaging: a clinical and diagnostic approach / Robert Carachi, editor

Online Resource




imaging

Computational methods and clinical applications for spine imaging: 6th International Workshop and Challenge, CSI 2019, Shenzhen, China, October 17, 2019, proceedings / Yunliang Cai, Liansheng Wang, Michel Audette, Guoyan Zheng, Shuo Li (eds.)

Online Resource




imaging

4-(4-Chloro-2-oxo-3(1H-phenanthro[9,10-d]imidazol-2-yl)-2H-chromen-6-yl) benzaldehyde as a fluorescent probe for medical imaging: linear and nonlinear optical properties

Photochem. Photobiol. Sci., 2020, 19,473-484
DOI: 10.1039/C9PP00478E, Paper
Przemysław Krawczyk
This study presents the full theoretical optical and biological characteristics of a new fluorescent probe based on the phenanthroimidazole backbone (PB5).
The content of this RSS Feed (c) The Royal Society of Chemistry




imaging

A dual-targeted CeO2–DNA nanosensor for real-time imaging of H2O2 to assess atherosclerotic plaque vulnerability

J. Mater. Chem. B, 2020, 8,3502-3505
DOI: 10.1039/C9TB02459J, Communication
Zhenhua Liu, Yujie Cao, Xiaona Zhang, Huazhen Yang, Yujie Zhao, Wen Gao, Bo Tang
A novel dual-targeted CeO2–DNA nanosensor by modifying with folic acid (FA) and CD36 antibody was designed.
The content of this RSS Feed (c) The Royal Society of Chemistry




imaging

Genetically encoded light-up RNA aptamers and their applications for imaging and biosensing

J. Mater. Chem. B, 2020, 8,3382-3392
DOI: 10.1039/C9TB02668A, Review Article
Puchakayala Swetha, Ze Fan, Fenglin Wang, Jian-Hui Jiang
Light-up RNA aptamers and their applications in bioimaging and biosensing of small ligands and biomacromolecules are described.
The content of this RSS Feed (c) The Royal Society of Chemistry




imaging

Fluorinated porphyrin-based theranostics for dual imaging and chemo-photodynamic therapy

J. Mater. Chem. B, 2020, Advance Article
DOI: 10.1039/D0TB00083C, Paper
Huaibin Zhang, Shaowei Bo, Kai Zeng, Jie Wang, Yu Li, Zhigang Yang, Xin Zhou, Shizhen Chen, Zhong-Xing Jiang
A modular strategy facilitates the convenient and standardized preparation of multifunctional theranostics for cancer therapy.
To cite this article before page numbers are assigned, use the DOI form of citation above.
The content of this RSS Feed (c) The Royal Society of Chemistry




imaging

Macrocyclic polyamine [12]aneN3 modified triphenylamine-pyrazine derivatives as efficient non-viral gene vectors with AIE and two-photon imaging properties

J. Mater. Chem. B, 2020, 8,3869-3879
DOI: 10.1039/D0TB00321B, Paper
Le-Le Ma, Ming-Xuan Liu, Xu-Ying Liu, Wan Sun, Zhong-Lin Lu, Yong-Guang Gao, Lan He
[12]aneN3 modified triphenylamine-pyrazines as non-viral gene vectors with AIE and two-photon imaging properties.
The content of this RSS Feed (c) The Royal Society of Chemistry




imaging

Molecular imaging of extracellular vesicles in vitro via Raman metabolic labelling

J. Mater. Chem. B, 2020, Advance Article
DOI: 10.1039/D0TB00620C, Paper
Open Access
  This article is licensed under a Creative Commons Attribution 3.0 Unported Licence.
Conor C. Horgan, Anika Nagelkerke, Thomas E. Whittaker, Valeria Nele, Lucia Massi, Ulrike Kauscher, Jelle Penders, Mads S. Bergholt, Steve R. Hood, Molly M. Stevens
Molecular imaging of extracellular vesicles in vitro via Raman metabolic labelling.
To cite this article before page numbers are assigned, use the DOI form of citation above.
The content of this RSS Feed (c) The Royal Society of Chemistry




imaging

Neuroelectrical brain imaging tools for the study of the efficacy of TV advertising stimuli and their application to neuromarketing / Giovanni Vecchiato [and three others]

Vecchiato, Giovanni, author




imaging

Feline Diagnostic Imaging


 
This book offers a comprehensive resource for imaging the feline patient, with an emphasis on the unique considerations of imaging cats. It focuses on radiology and ultrasound, with some coverage of advanced imaging such as computed tomography and magnetic resonance imaging. Incorporating more than 1750 high-quality images, it is an invaluable reference for any veterinary practitioner with a significant feline caseload. 

Read More...