vis

Best moments from Day 2 of Trump's visit

Spectacle turned to substance on Day 2 of United States President Donald Trump's visit as he had talks with Prime Minister Narendra Modi in the nation's capital.After a day of lapping up attention from cheering crowds and taking in India's most famous sites, including the Taj Mahal, Trump lay the groundwork for longer-term deals on trade and other matters.Take a look.




vis

LG Baijal visits riot-hit areas, interacts with locals

Interacting with locals, he observed that the situation is gradually improving day by day, and urged them not to pay attention to rumours and avoid circulating unconfirmed messages.




vis

Mortality increases if COVID-19 positive person delays in visiting hospital...

Mortality increases if COVID-19 positive person delays in visiting hospital...




vis

CM slams attempt to sow communal division

Chief Minister Pinarayi Vijayan on Saturday condemned the purported attempted to sow seeds of communal strife in the State during the time of the COVI




vis

Govt revises patient discharge rules

Govt revises patient discharge rules




vis

Centre’s advisory to NE states on returnees during lockdown

Centre’s advisory to NE states on returnees during lockdown




vis

Air India issues advisory for US-bound Indian students holding F or M visa




vis

Govt revises discharge policy: Severe Covid cases will have to test negative through RT-PCR




vis

ICICI Bank Q4 net up 26%, provisions rise

‘Net NPA at lowest in 19 quarters’




vis

Wimbledon visit made me take up the game: Zeeshan

Ashutosh says he gained from following his father’s disciplined methods




vis

Trump administration tightens visas for Chinese reporters

The Trump administration is tightening visa guidelines for Chinese journalists in response to the treatment of US journalists in China, as tensions flare between the two nations over the coronavirus.




vis

Public advised to exercise caution while handling biomedical waste

The district administration has advised public to exercise caution while handling biomedical waste of persons in home quarantine or from quarantine fa




vis

Minister visits site for relocation of Uddandapur reservoir oustees

‘Proper opportunities would be created for their livelihood’




vis

Visakhapatnam gas leak: LG Polymers apologises, offers ‘every support’ to affected

Visakhapatnam gas leak: LG Polymers apologises, offers ‘every support’ to affected




vis

Hong Kong: Trump administration tightens visas for Chinese reporters - Times of India

Hong Kong: Trump administration tightens visas for Chinese reporters - Times of India




vis

Covid-19: New BMC chief hits the ground; visits Nair hospital, Dharavi

Covid-19: New BMC chief hits the ground; visits Nair hospital, Dharavi




vis

Mumbai: New civic chief warns of surprise visits

Mumbai: New civic chief warns of surprise visits




vis

Trump 'torn' over US-China trade deal as advisers push to fulfill its terms

The deal brought a partial truce to an 18-month trade war between the world's two largest economies that heaped U.S. tariffs on some $370 billion worth of Chinese imports




vis

Punjab Governor visits vintage car rally in Gurugram




vis

Hindu pilgrims leaves for Pakistan to visit Katas Raj temple




vis

All-party delegation from Punjab to meet PM for simplification of process to visit Kartarpur Sahib




vis

Kartarpur visitors quizzed in national security interest: Punjab CM




vis

Govt not to ban Kartarpur Sahib visit: Akal Takht




vis

Akal Takht asks govt not to ban Kartapur Sahib visit




vis

Golden Temple may prohibit devotees' visit in wake of corona scare: Cong MP




vis

Stamp on hands of people who are advised to be in home quarantine, says Punjab minister




vis

Follow government advisories to fight COVID-19: Punjab Health Minister




vis

Pathankot Forest Division makes efforts to tackle COVID-19 outbreak




vis

Jalianwala Bagh memorial to remain closed for visitors till June 15




vis

Punjab minister Bharat Bhushan Ashu visits Ludhiana mandi




vis

Punjab govt issues advisory on maintaining hygiene, sanitization in banks




vis

If your neighbour is partying, call police: Chandigarh Advisor




vis

Chandigarh Advisor gets too many requests for b'day cakes




vis

COVID-19: Punjab issues advisory for safe operation of govt offices




vis

10 more trains to U.P. soon, claims Fadnavis

CM has assured safe passage for migrant workers, says Sharad Pawar




vis

Protocol revised to discharge corona patients

From now on, only those with severe Covid-19 symptoms will need to undergo RT-PCR tests, that too only one and not two consecutive tests that were mandatory earlier, for their release from the hospital after treatment. Covid-positive patients with mild and moderate symptoms will no longer require the mandatory negative confirmatory tests before they are sent home.





vis

Correlated changes in structure and viscosity during gelatinization and gelation of tapioca starch granules

Melting of the semicrystalline structure of native tapioca starch granules is correlated to solution viscosity for elucidating gelatinization and gelation processes.





vis

Visualization Bench for the screening of crystallization assays and the automation of in situ experiments




vis

Development of basic building blocks for cryo-EM: the emcore and emvis software libraries

This article presents an overview of the development of two basic software libraries for image manipulation and data visualization in cryo-EM: emcore and emvis.




vis

SVAT4: a computer program for visualization and analysis of crystal structures

SVAT4 is a computer program for interactive visualization of three-dimensional crystal structures, including chemical bonds and magnetic moments. A wide range of functions, e.g. revealing atomic layers and polyhedral clusters, are available for further structural analysis. Atomic sizes, colors, appearance, view directions and view modes (orthographic or perspective views) are adjustable. Customized work for the visualization and analysis can be saved and then reloaded. SVAT4 provides a template to simplify the process of preparation of a new data file. SVAT4 can generate high-quality images for publication and animations for presentations. The usability of SVAT4 is broadened by a software suite for simulation and analysis of electron diffraction patterns.




vis

Scanning electron microscopy as a method for sample visualization in protein X-ray crystallography

Developing methods to determine high-resolution structures from micrometre- or even submicrometre-sized protein crystals has become increasingly important in recent years. This applies to both large protein complexes and membrane proteins, where protein production and the subsequent growth of large homogeneous crystals is often challenging, and to samples which yield only micro- or nanocrystals such as amyloid or viral polyhedrin proteins. The versatile macromolecular crystallography microfocus (VMXm) beamline at Diamond Light Source specializes in X-ray diffraction measurements from micro- and nanocrystals. Because of the possibility of measuring data from crystalline samples that approach the resolution limit of visible-light microscopy, the beamline design includes a scanning electron microscope (SEM) to visualize, locate and accurately centre crystals for X-ray diffraction experiments. To ensure that scanning electron microscopy is an appropriate method for sample visualization, tests were carried out to assess the effect of SEM radiation on diffraction quality. Cytoplasmic polyhedrosis virus polyhedrin protein crystals cryocooled on electron-microscopy grids were exposed to SEM radiation before X-ray diffraction data were collected. After processing the data with DIALS, no statistically significant difference in data quality was found between datasets collected from crystals exposed and not exposed to SEM radiation. This study supports the use of an SEM as a tool for the visualization of protein crystals and as an integrated visualization tool on the VMXm beamline.




vis

Visualization of protein crystals by high-energy phase-contrast X-ray imaging

For the extraction of the best possible X-ray diffraction data from macromolecular crystals, accurate positioning of the crystals with respect to the X-ray beam is crucial. In addition, information about the shape and internal defects of crystals allows the optimization of data-collection strategies. Here, it is demonstrated that the X-ray beam available on the macromolecular crystallo­graphy beamline P14 at the high-brilliance synchrotron-radiation source PETRA III at DESY, Hamburg, Germany can be used for high-energy phase-contrast microtomography of protein crystals mounted in an optically opaque lipidic cubic phase matrix. Three-dimensional tomograms have been obtained at X-ray doses that are substantially smaller and on time scales that are substantially shorter than those used for diffraction-scanning approaches that display protein crystals at micrometre resolution. Adding a compound refractive lens as an objective to the imaging setup, two-dimensional imaging at sub-micrometre resolution has been achieved. All experiments were performed on a standard macromolecular crystallography beamline and are compatible with standard diffraction data-collection workflows and apparatus. Phase-contrast X-ray imaging of macromolecular crystals could find wide application at existing and upcoming low-emittance synchrotron-radiation sources.




vis

Development of basic building blocks for cryo-EM: the emcore and emvis software libraries

Image-processing software has always been an integral part of structure determination by cryogenic electron microscopy (cryo-EM). Recent advances in hardware and software are recognized as one of the key factors in the so-called cryo-EM resolution revolution. Increasing computational power has opened many possibilities to consider more demanding algorithms, which in turn allow more complex biological problems to be tackled. Moreover, data processing has become more accessible to many experimental groups, with computations that used to last for many days at supercomputing facilities now being performed in hours on personal workstations. All of these advances, together with the rapid expansion of the community, continue to pose challenges and new demands on the software-development side. In this article, the development of emcore and emvis, two basic software libraries for image manipulation and data visualization in cryo-EM, is presented. The main goal is to provide basic functionality organized in modular components that other developers can reuse to implement new algorithms or build graphical applications. An additional aim is to showcase the importance of following established practices in software engineering, with the hope that this could be a first step towards a more standardized way of developing and distributing software in the field.




vis

GIDVis: a comprehensive software tool for geometry-independent grazing-incidence X-ray diffraction data analysis and pole-figure calculations

GIDVis is a software package based on MATLAB specialized for, but not limited to, the visualization and analysis of grazing-incidence thin-film X-ray diffraction data obtained during sample rotation around the surface normal. GIDVis allows the user to perform detector calibration, data stitching, intensity corrections, standard data evaluation (e.g. cuts and integrations along specific reciprocal-space directions), crystal phase analysis etc. To take full advantage of the measured data in the case of sample rotation, pole figures can easily be calculated from the experimental data for any value of the scattering angle covered. As an example, GIDVis is applied to phase analysis and the evaluation of the epitaxial alignment of pentacene­quinone crystallites on a single-crystalline Au(111) surface.




vis

ClickX: a visualization-based program for preprocessing of serial crystallography data

Serial crystallography is a powerful technique in structure determination using many small crystals at X-ray free-electron laser or synchrotron radiation facilities. The large diffraction data volumes require high-throughput software to preprocess the raw images for subsequent analysis. ClickX is a program designated for serial crystallography data preprocessing, capable of rapid data sorting for online feedback and peak-finding refinement by parameter optimization. The graphical user interface (GUI) provides convenient access to various operations such as pattern visualization, statistics plotting and parameter tuning. A batch job module is implemented to facilitate large-data-volume processing. A two-step geometry calibration for single-panel detectors is also integrated into the GUI, where the beam center and detector tilting angles are optimized using an ellipse center shifting method first, then all six parameters, including the photon energy and detector distance, are refined together using a residual minimization method. Implemented in Python, ClickX has good portability and extensibility, so that it can be installed, configured and used on any computing platform that provides a Python interface or common data file format. ClickX has been tested in online analysis at the Pohang Accelerator Laboratory X-ray Free-Electron Laser, Korea, and the Linac Coherent Light Source, USA. It has also been applied in post-experimental data analysis. The source code is available via https://github.com/LiuLab-CSRC/ClickX under a GNU General Public License.




vis

DatView: a graphical user interface for visualizing and querying large data sets in serial femtosecond crystallography

DatView is a new graphical user interface (GUI) for plotting parameters to explore correlations, identify outliers and export subsets of data. It was designed to simplify and expedite analysis of very large unmerged serial femtosecond crystallography (SFX) data sets composed of indexing results from hundreds of thousands of microcrystal diffraction patterns. However, DatView works with any tabulated data, offering its functionality to many applications outside serial crystallography. In DatView's user-friendly GUI, selections are drawn onto plots and synchronized across all other plots, so correlations between multiple parameters in large multi-parameter data sets can be rapidly identified. It also includes an item viewer for displaying images in the current selection alongside the associated metadata. For serial crystallography data processed by indexamajig from CrystFEL [White, Kirian, Martin, Aquila, Nass, Barty & Chapman (2012). J. Appl. Cryst. 45, 335–341], DatView generates a table of parameters and metadata from stream files and, optionally, the associated HDF5 files. By combining the functionality of several commonly needed tools for SFX in a single GUI that operates on tabulated data, the time needed to load and calculate statistics from large data sets is reduced. This paper describes how DatView facilitates (i) efficient feedback during data collection by examining trends in time, sample position or any parameter, (ii) determination of optimal indexing and integration parameters via the comparison mode, (iii) identification of systematic errors in unmerged SFX data sets, and (iv) sorting and highly flexible data filtering (plot selections, Boolean filters and more), including direct export of subset CrystFEL stream files for further processing.




vis

High-viscosity sample-injection device for serial femtosecond crystallography at atmospheric pressure

A sample-injection device has been developed at SPring-8 Angstrom Compact Free-Electron Laser (SACLA) for serial femtosecond crystallography (SFX) at atmospheric pressure. Microcrystals embedded in a highly viscous carrier are stably delivered from a capillary nozzle with the aid of a coaxial gas flow and a suction device. The cartridge-type sample reservoir is easily replaceable and facilitates sample reloading or exchange. The reservoir is positioned in a cooling jacket with a temperature-regulated water flow, which is useful to prevent drastic changes in the sample temperature during data collection. This work demonstrates that the injector successfully worked in SFX of the human A2A adenosine receptor complexed with an antagonist, ZM241385, in lipidic cubic phase and for hen egg-white lysozyme microcrystals in a grease carrier. The injection device has also been applied to many kinds of proteins, not only for static structural analyses but also for dynamics studies using pump–probe techniques.




vis

Mercury 4.0: from visualization to analysis, design and prediction

The program Mercury, developed at the Cambridge Crystallographic Data Centre, was originally designed primarily as a crystal structure visualization tool. Over the years the fields and scientific communities of chemical crystallography and crystal engineering have developed to require more advanced structural analysis software. Mercury has evolved alongside these scientific communities and is now a powerful analysis, design and prediction platform which goes a lot further than simple structure visualization.