mea Gabriel-Roiter measure, representation dimension and rejective chains. (arXiv:1903.05555v2 [math.RT] UPDATED) By arxiv.org Published On :: The Gabriel-Roiter measure is used to give an alternative proof of the finiteness of the representation dimension for Artin algebras, a result established by Iyama in 2002. The concept of Gabriel-Roiter measure can be extended to abelian length categories and every such category has multiple Gabriel-Roiter measures. Using this notion, we prove the following broader statement: given any object $X$ and any Gabriel-Roiter measure $mu$ in an abelian length category $mathcal{A}$, there exists an object $X'$ which depends on $X$ and $mu$, such that $Gamma = operatorname{End}_{mathcal{A}}(X oplus X')$ has finite global dimension. Analogously to Iyama's original results, our construction yields quasihereditary rings and fits into the theory of rejective chains. Full Article
mea Gaussian invariant measures and stationary solutions of 2D Primitive Equations. (arXiv:2005.03339v1 [math.PR]) By arxiv.org Published On :: We introduce a Gaussian measure formally preserved by the 2-dimensional Primitive Equations driven by additive Gaussian noise. Under such measure the stochastic equations under consideration are singular: we propose a solution theory based on the techniques developed by Gubinelli and Jara in cite{GuJa13} for a hyperviscous version of the equations. Full Article
mea An alternate definition of the Parry measure. (arXiv:2005.03282v1 [math.DS]) By arxiv.org Published On :: In this paper, we give an alternate definition of the well-known Parry measure on an aperiodic subshift of finite type using correlation between the forbidden words. We use the concept of the local escape rate to obtain this definition. We also compute Perron eigenvectors corresponding to the Perron root of the associated adjacency matrix. Full Article
mea Pointwise densities of homogeneous Cantor measure and critical values. (arXiv:2005.03269v1 [math.DS]) By arxiv.org Published On :: Let $Nge 2$ and $ hoin(0,1/N^2]$. The homogenous Cantor set $E$ is the self-similar set generated by the iterated function system [ left{f_i(x)= ho x+frac{i(1- ho)}{N-1}: i=0,1,ldots, N-1 ight}. ] Let $s=dim_H E$ be the Hausdorff dimension of $E$, and let $mu=mathcal H^s|_E$ be the $s$-dimensional Hausdorff measure restricted to $E$. In this paper we describe, for each $xin E$, the pointwise lower $s$-density $Theta_*^s(mu,x)$ and upper $s$-density $Theta^{*s}(mu, x)$ of $mu$ at $x$. This extends some early results of Feng et al. (2000). Furthermore, we determine two critical values $a_c$ and $b_c$ for the sets [ E_*(a)=left{xin E: Theta_*^s(mu, x)ge a ight}quad extrm{and}quad E^*(b)=left{xin E: Theta^{*s}(mu, x)le b ight} ] respectively, such that $dim_H E_*(a)>0$ if and only if $a<a_c$, and that $dim_H E^*(b)>0$ if and only if $b>b_c$. We emphasize that both values $a_c$ and $b_c$ are related to the Thue-Morse type sequences, and our strategy to find them relies on ideas from open dynamics and techniques from combinatorics on words. Full Article
mea Approximate Performance Measures for a Two-Stage Reneging Queue. (arXiv:2005.03239v1 [math.PR]) By arxiv.org Published On :: We study a two-stage reneging queue with Poisson arrivals, exponential services, and two levels of exponential reneging behaviors, extending the popular Erlang A model that assumes a constant reneging rate. We derive approximate analytical formulas representing performance measures for the two-stage queue following the Markov chain decomposition approach. Our formulas not only give accurate results spanning the heavy-traffic to the light-traffic regimes, but also provide insight into capacity decisions. Full Article
mea Measuring Social Bias in Knowledge Graph Embeddings. (arXiv:1912.02761v2 [cs.CL] UPDATED) By arxiv.org Published On :: It has recently been shown that word embeddings encode social biases, with a harmful impact on downstream tasks. However, to this point there has been no similar work done in the field of graph embeddings. We present the first study on social bias in knowledge graph embeddings, and propose a new metric suitable for measuring such bias. We conduct experiments on Wikidata and Freebase, and show that, as with word embeddings, harmful social biases related to professions are encoded in the embeddings with respect to gender, religion, ethnicity and nationality. For example, graph embeddings encode the information that men are more likely to be bankers, and women more likely to be homekeepers. As graph embeddings become increasingly utilized, we suggest that it is important the existence of such biases are understood and steps taken to mitigate their impact. Full Article
mea Rationing Protective Gear Means Checking on Coronavirus Patients Less Often. This Can Be Deadly By www.inlander.com Published On :: Fri, 10 Apr 2020 14:51:13 -0700 Low on essential supplies and fearing they’ll get sick, doctors and nurses told ProPublica in-person care for coronavirus patients has been scaled back. In some cases, it’s causing serious harm. By Joshua Kaplan, Lizzie Presser and Maya Miller, ProPublica Every morning, between 7 and 8, at Long Island Jewish Medical Center in Queens, several coronavirus patients are pronounced dead.… Full Article News/Nation & World
mea Meat gets rarer in the grocery aisle and the drive-thru By www.inlander.com Published On :: Tue, 05 May 2020 17:30:31 -0700 By David Yaffe-Bellany and Michael Corkery The New York Times Company Hundreds of Wendy’s restaurants have run out of hamburgers.… Full Article Nation & World
mea Sammy Eubanks, Cami Bradley team up for virtual concert Saturday for Meals on Wheels By www.inlander.com Published On :: Fri, 08 May 2020 16:44:08 -0700 Two beloved Spokane-based entertainers are teaming up this weekend for a good cause.… Full Article Music/Music News
mea Determination of physical connectivity status of devices based on electrical measurement By www.freepatentsonline.com Published On :: Tue, 12 Jan 2016 08:00:00 EST Embodiments of the invention are generally directed to determination of physical connectivity status of devices based on electrical measurement. An embodiment of a method includes discovering a connection of a first device with a second device, and performing an electrical measurement of the second device by the first device via the connection between the first device and the second device, where performing the electrical measurement includes sensing by the first device of an element of the second device. The method further includes, if the sensing by the first device fails to detect the element of the second device and a predetermined condition for the electrical measurement is enabled, then determining by the first device that the connection with the second device has been lost. Full Article
mea System for generating readable and meaningful descriptions of stream processing source code By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT An information processing system, computer readable storage medium, and method for automatically generating human readable and meaningful documentation for one or more source code files. A processor of the information processing system receives one or more source code files containing source code artifacts (SCA) and infers semantics therefrom based on predefined rules. The processor, based on the inferred semantics, extracts documentation from another source code file. The extracted documentation and the inferred semantics are used to generate new human readable and meaningful documentation for the SCA, such new documentation being previously missing from the SCA. The generated new documentation is included with the SCA in one or more source code files. Full Article
mea Speech recognition apparatus with means for preventing errors due to delay in speech recognition By www.freepatentsonline.com Published On :: Tue, 08 Jan 1991 08:00:00 EST When a speech sound of at least a predetermined sound pressure is externally input while a time measurement is not being performed, a time measuring circuit starts a time measurement responsive to a signal from a speech detector. When another speech sound of at least a predetermined sound pressure is externally input while a time measurement is being performed by the time measuring circuit, a measurement time measured by the time measuring circuit at this moment is stored in a time information memory. After a predetermined time has elapsed, if a speech recognition circuit recognizes that the externally input speech sound is a "stop" command, the time measurement operation performed by the time measuring circuit is stopped, and the time information stored in the time information memory is read out and displayed as measurement time information on a display unit. Full Article
mea Apparatus for measuring intervals between signal edges By www.freepatentsonline.com Published On :: Tue, 12 Jun 2001 08:00:00 EDT An apparatus for measuring a time interval between a start signal edge and a stop signal edge provides a stable clock signal as input to a delay line formed by a series of similar logic gates. The output signal of the last gate of the series is phase locked to the clock signal by adjusting a bias signal controlling the switching speed of all gates. The clock signal and the output signal of each gate form a set of phase distributed periodic timing signals applied to a start time measurement unit (TMU) and a similar stop TMU. The start TMU counts edges of one of the timing signals occurring between an edge of an arming signal and the start signal edge and generates output data representing a time delay between the arming signal and the start signal edge. The data represents the start delay as a whole and fractional number of clock signal periods by conveying the counter output and by indicating which of the timing signals had an edge most closely following the start signal edge. The stop TMU similarly produces output data indicating a whole an fractional number of clock cycles occurring between the arming signal and the stop signal edge. The delay represented by the start TMU output data is subtracted from the delay represented by the stop TMU output data to determine the interval between the start and stop signal edges. Full Article
mea Prefetch optimizer measuring execution time of instruction sequence cycling through each selectable hardware prefetch depth and cycling through disabling each software prefetch instruction of an instruction sequence of interest By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT A prefetch optimizer tool for an information handling system (IHS) may improve effective memory access time by controlling both hardware prefetch operations and software prefetch operations. The prefetch optimizer tool selectively disables prefetch instructions in an instruction sequence of interest within an application. The tool measures execution times of the instruction sequence of interest when different prefetch instructions are disabled. The tool may hold hardware prefetch depth constant while cycling through disabling different prefetch instructions and taking corresponding execution time measurements. Alternatively, for each disabled prefetch instruction in the instruction sequence of interest, the tool may cycle through different hardware prefetch depths and take corresponding execution time measurements at each hardware prefetch depth. The tool selects a combination of hardware prefetch depth and prefetch instruction disablement that may improve the execution time in comparison with a baseline execution time. Full Article
mea Implementing security measures for authorized tokens used in mobile transactions By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT Security measures for tokens comprise storing security rules associated with a generated token in a memory. A processor, communicatively coupled to the memory, accesses the security rules associated with the generated token and determines whether to encrypt the generated token by applying at least a portion of the security rules to the generated token. The processor encrypts the generated token. An interface, communicatively coupled to the processor, communicates the encrypted token to a mobile device associated with a user. Full Article
mea Velocity measurement of MR-imaged fluid flows By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT Velocity of MR-imaged fluid flows is measured. Data representing a measure of distance traveled by flowing fluid appearing in at least two MR images of a subject's tissue taken at different respective imaging times is generated. Data representing at least one fluid velocity measurement of the flowing fluid is generated by calculating at least one instance of distance traveled by the fluid divided by elapsed time during travel based on different respective imaging times. Data representing at least one fluid velocity measurement is then output to at least one of: (a) a display screen, (b) a non-transitory data storage medium, and (c) a remotely located site. Full Article
mea Lymphatic pressure-measuring system and method for controlling same By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT The present invention has an object to measure lymphatic pressure with more safety and ease at lower cost. To achieve this, a lymphatic pressure-measuring system 1 includes: a manchette 11 fitted on a vital observation portion; a measurement unit 13 that measures and outputs pressure of the manchette 11; an infrared camera 21 that detects fluorescence emitted from fluorescent dye previously injected into a lymph vessel in the vital observation portion; and an image processing device 22 that generates and displays an image showing a position of the fluorescent dye in the lymph vessel based on a detection result of the infrared camera 21. The infrared camera 21 repeats the detection while the pressure of the manchette 11 decreases from first pressure to block a lymph flow in the vital observation portion to second pressure at restart of the lymph flow. The measurement unit 13 repeats the measurement during the period. Full Article
mea Biometric monitoring device with heart rate measurement activated by a single user-gesture By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT A biometric monitoring device measuring various biometric information is provided that allows the person to take and/or display a heart rate reading by a simple user interaction with the device, e.g., by simply touching a heart rate sensor surface area or moving the device in a defined motion pattern. Some embodiments of this disclosure provide biometric monitoring devices that allow a person to get a quick heart rate reading without removing the device or interrupting their other activities. Some embodiments provide heart rate monitoring with other desirable features such as feedback on data acquisition status. Full Article
mea Apparatus and method for measuring physiological signal quality By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT An apparatus and method for determining a signal quality of an input signal representing a repetitious phenomena derived from at least one sensor connected to a patient is provided. A detector receives the input signal and determines data representing the repetitious phenomena from the input signal for use in determining at least one patient parameter. A measurement processor is electrically coupled to the detector that determines a first signal quality value by identifying at least one feature of the repetitious phenomena data and compares the at least one feature of a first set of the determined repetitious phenomena data with a second set of the determined repetitious phenomena data to determine a feature variability value and using the feature variability value to determine a stability value representative of the quality of the input signal. Full Article
mea Method and apparatus for eliminating loading and electrode polarization effects in impedance measurements for tissues and electrolytes By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT A device and method for accurately characterizing tissue impedance employs multiple electrodes at a plurality of separation distances to cancel the effects of front end loading leakage currents and electrode polarization to improve the accuracy of sensitive impedance measurements used to identify cancerous tissues. These measurements may be automated over a range of frequencies. Full Article
mea Method for the production of 2-octyl acrylate by means of transesterification By www.freepatentsonline.com Published On :: Tue, 28 Apr 2015 08:00:00 EDT The invention relates to the production of 2-octylacrylate of high purity and in good yield using ethyl titanate in solution in 2-octanol or 2-octyl titanate as a transesterification catalyst. Full Article
mea Method for producing mono-aminofunctionalized dialkylphosphinic acids and esters and salts thereof by means of acrylnitriles and use thereof By www.freepatentsonline.com Published On :: Tue, 19 May 2015 08:00:00 EDT The invention relates to a method for producing mono-aminofunctionalized dialkylphosphinic acids and esters and salts thereof by means of acrylnitriles, characterized in that a) a phosphinic acid source (I) is reacted with olefins (IV) to yield an alkylphosphonic acid, salt or ester (II) thereof in the presence of a catalyst A, b) the thus obtained alkylphosphonic acid, salt or ester (II) thereof is reacted with an acrylnitrile of formula (V) to yield a mono-functionalized dialkylphosphinic acid derivative (VI) in the presence of a catalyst B, and c) the thus obtained mono-functionalized dialkylphosphinic acid derivative (VI) is reacted to yield a mono-aminofunctionalized dialkylphosphinic acid derivative (III) in the presence of a catalyst C or a reduction agent, wherein R1, R2, R3, R4, R5, R6, R7 are the same or different and stand independently of each other, among other things, for H, C1-C18 alkyl, C6-C18 aryl, C6-C18 aralkyl, C6-C18 alkylaryl and X stands for H, C1-C18 alkyl, C6-C18 aryl, C6-C18 aralkyl, C6-C18 alkylaryl, Mg, Ca, Al, Sb, Sn, Ge, Ti, Fe, Zr, Zn, Ce, Bi, Sr, Mn, Cu, Ni, Li, Na, K and/or a protonized nitrogen base, and Y stands for a mineral acid, a carboxylic acid, a Lewis acid or an organic acid, n=an integer or fractional number of 0 to 4 and the catalysts A and C are formed by transition metals, transition metal compounds and/or catalyst systems composed of a transition metal and/or a transition metal compound and at least one ligand, and catalyst B is formed by compounds forming peroxides, peroxo compounds, azo compounds, alkali metals, alkaline earth metals, alkali hydrides, alkaline earth hydrides and/or alkali alcoholates and alkaline earth alcoholates. Full Article
mea Maximum depth of investigation of measurements in a formation By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT The present disclosure relates to a method to determine a volume of clearance surrounding a wellbore. A logging tool is provided. The logging tool may be disposed on a wireline, a drill string, or a wired drill pipe. A formation property is obtained using the logging tool. The formation property may include a voltage, a bulk resistivity, a horizontal resistivity, a vertical resistivity, a porosity, a permeability, a fluid saturation, an NMR relaxation time, a borehole size, a borehole shape, a borehole fluid composition, an MWD parameter, or an LWD parameter. The maximum depth of investigation into the subsurface formation is determined using a model response and a noise level, and the volume of clearance is determined using the determined maximum depth of investigation. The maximum depth of investigation and volume of clearance may be determined even though no boundary layers are detected. Full Article
mea Molecular flux rates through critical pathways measured by stable isotope labeling in vivo, as biomarkers of drug action and disease activity By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT The methods described herein enable the evaluation of compounds on subjects to assess their therapeutic efficacy or toxic effects. The target of analysis is the underlying biochemical process or processes (i.e., metabolic process) thought to be involved in disease pathogenesis. Molecular flux rates within the one or more biochemical processes serve as biomarkers and are quantitated and compared with the molecular flux rates (i.e., biomarker) from control subjects (i.e., subjects not exposed to the compounds). Any change in the biomarker in the subject relative to the biomarker in the control subject provides information to evaluate therapeutic efficacy of an administered drug or a toxic effect and to develop the compound further if desired. In one aspect of the invention, stable isotope-labeled substrate molecules are administered to a subject and the label is incorporated into targeted molecules in a manner that reveals molecular flux rates through metabolic pathways of interest. Full Article
mea Absolute position measurement apparatus and method By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT An absolute position measurement apparatus measures an absolute position of an object to be measured using a first light source and a second light source which has coherency lower than that of the first light source. The absolute position measurement apparatus includes a measurement part which measures a point where phases of interference signals from the first and the second light sources coincide with each other or a point where an intensity of the interference signal from the second light source is maximized, an origin defining part which defines the point measured by the measurement part as an origin position, a phase storing part which stores the phase of the interference signal from the first light source at the origin position, an origin redefining part which redefines the origin position, and a position calculating part which calculates the absolute position of the object to be measured. Full Article
mea Implantable system for flow measurement including charge amplifier By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT An implantable medical device lead having a flow measurement sensor mounted thereon is provided with a capsule mounted proximate to the sensor. The capsule is used to house electrical circuitry corresponding to the sensor in order to prevent impedance on conductors of the lead, which gradually decreases over chronic periods, from directly affecting signal transmission between the sensor and the electrical circuitry. The electrical circuitry includes a charge amplifier used for processing signals from the sensor. In some cases, the amplifier can be initially calibrated and periodically tuned so as to have consistent functioning with the sensor over chronic periods. Full Article
mea Pneumatic compression garment with noise attenuating means By www.freepatentsonline.com Published On :: Tue, 19 May 2015 08:00:00 EDT A pneumatic compression garment includes a flexible member for placement on a limb of a human body. A bladder in the flexible member defines an inflatable chamber. The bladder has an opening through which the inflatable chamber is inflated. A port mounted on the bladder has an air inlet adapted for communication with a source of pressurized air and an air outlet in communication with the inflatable chamber via the opening in the bladder. Pressurized air is delivered from into the inflatable chamber for inflating the inflatable chamber and thereby applying a compression force to the limb when the flexible member is in place on the limb. An air diverter affixed to an inside surface of a first sheet of the bladder and configured to divert air entering the inflatable chamber from directly impinging against an inside surface of a second sheet of the bladder. Full Article
mea Quick-release cymeal mounting fastener By www.freepatentsonline.com Published On :: Tue, 02 Oct 1990 08:00:00 EDT A fastener for quick-mounting a cymbal to an upright cymbal support rod comprising a pair of half-round sleeve members arranged in face-to-face relationship forming a cylindrical surface therebetween for grasping the cymbal mounting rod; a tab extending upward from each sleeve member including means for pivoting said members near said tabs so that, by squeezing said tabs together, said sleeve members are pivoted away from each other; a pair of split flange members, one attached to the lower end of each sleeve member, spaced apart from said tab, arranged in co-planar alignment when said members are in adjacent contact to form a planar compression surface for pressing toward a cymbal placed on the cymbal mounting rod; and, means for biasing said sleeve members into full contact about the cymbal mounting rod threaded end to hold the cymbal on the rod. Full Article
mea Method and apparatus for measurement for inter-cell interference coordination in radio communication system By www.freepatentsonline.com Published On :: Tue, 13 Oct 2015 08:00:00 EDT A wireless communication system and, more specifically, a measurement method and apparatus for inter-cell interference coordination in a wireless communication system are disclosed. Herein, a method for supporting measurement of a User Equipment (UE) by a first base station in a wireless communication system includes the steps of acquiring information of downlink subframe configuration of a second base station, determining measurement objects of downlink resource of the first base station based on the downlink subframe configuration of the second base station; transmitting information of the measurement objects to the UE, and receiving measurement result for the measurement objects from the UE. Full Article
mea Mixing and kneading machine for continual compounding and method of implementing continual compounding by means of a mixing and kneading machine By www.freepatentsonline.com Published On :: Tue, 05 May 2015 08:00:00 EDT A mixing and kneading machine (1) for continual compounding comprises a screw shaft (3) rotating in a casing (2) and simultaneously moving axially translationally. To sustainably enhance the efficiency of the machine as regards its material thruput per unit of time the screw shaft (3) comprises at least four groups of radial screw vanes (4a, 4b, 4c, 4d) evenly distributed circumferentially, each group consisting of a plurality of screw vanes in axial sequence. The outer diameter (Da) of the screw shaft ranges from 400 to 800 millimeters. The rotary speed of the screw shaft (3) ranges from 30 to 80 rpm. A mixing and kneading machine (1) engineered as such is particularly suitable for compounding an anodic mass in the production of electrodes—anodes—for the aluminum industry. Full Article
mea Changing and measuring consistency By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT A measuring device comprising at least one mixer structure to receive a fiber suspension sample from at least one process part. Each mixer structure is provided with a measuring unit, a feeding valve for feeding feed liquid into a sample line for pushing the sample in the sample line towards the measuring unit, a mixing valve structure for feeding dilution liquid into the mixer structure The mixer structure mixes the flowing sample and the dilution liquid with one another in order to reduce the consistency of the sample. The measuring device measures from the first part of the mixed sample one property of the fiber suspension and the measuring device measures from the second part of the mixed sample a further property. Full Article
mea Method for machining a series of workpieces by means of at least one machining jet By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT The method for machining a series of workpieces (21) via at least one machining jet includes the following steps: each workpiece (21) is associated with an identifier for uniquely identifying the workpiece,during the machining of a respective workpiece, the temporal characteristic of the machining jet is detected by at least one sensor (30),the detected temporal characteristic is evaluated so as to obtain at least one comparative value, andfor detecting incorrect machining, the at least one comparative value is compared with at least one threshold value. Full Article
mea Measuring signal to noise ratio of a WDM optical signal By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT A WDM optical signal is transmitted through a tunable optical filter and is polarization-nulled to find optical signal to noise ratio of individual WDM channels. The polarization nulling can be performed using a heuristic multipoint extrema search method, such as Nelder-Mead method. A plurality of checkpoints can be included in the search to verify the progress and to improve the overall robustness of a real-time polarization nulling. Full Article
mea Cartridge with fine adjustment means By www.freepatentsonline.com Published On :: Tue, 17 Mar 2015 08:00:00 EDT Cartridge for supporting at least one cutting insert and for being received on a tool body is disclosed. At least a first portion of the cartridge may be stationary mounted and the cartridge includes at least one pocket for receiving a cutting element. A coarse and a fine adjustment means are provided by means of which at least a second portion of the cartridge including the pocket may be moved with respect to the tool body and wherein the coarse and the fine adjustment means are merely provided at the cartridge. Full Article
mea Biosensors and bio-measurement systems using the same By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT A biosensor is provided. The biosensor is used to sense a biological sample and has a code representing features of the biosensor. The biosensor includes a substrate and a conductive layer. The conductive layer is disposed on a first side of the substrate and includes a first conductive loop and a second conductive loop. The first conductive loop is formed between a first node and a second node and has a first impedance. The second conductive loop is formed between the second node and a third node and has a second impedance. The code is determined according to a comparison result between the second impedance and the first impedance. Full Article
mea Measuring apparatus and referencing method for a digital laser distance meter, and laser distance meter By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT A handheld distance measuring instrument includes a first emission device, a first reception device and a second reception device. The first emission device is configured to emit an optical measurement radiation onto a target object. The first reception device is configured to detect the radiation returning from the target object. The second reception device is configured in order to detect a reference radiation internal to the instrument. The reception devices respectively include a first detector unit, a second detector unit, a first time measurement unit, and a second time measurement unit. The first time measurement unit is configured to be connected selectively to the first detector unit and to the second detector unit. The second time measurement unit is configured to be connected selectively to the first detector unit and to the second detector unit. Full Article
mea Measuring polarization crosstalk in optical birefringent materials and devices based on reduction of line broadening caused by birefringent dispersion By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT Techniques and devices for measuring polarization crosstalk in birefringence optical media including polarization maintaining fiber. Full Article
mea Interference measurement device and measurement method By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT [Problem to be Solved] To improve the measurement accuracy of an interference measurement device which utilizes interference of light. [Means for Solution] An interference measurement device includes a light source 10 for emitting supercontinuum light (SC light), an optical fiber coupler 11 for splitting the SC light into measurement light and reference light, a dispersion compensation element 12, a drive unit 13 for moving the dispersion compensation element 12, and light-receiving means 14 for measuring an interference waveform produced as a result of interference between the measurement light and the reference light. A measurement object 15 to be measured is an Si substrate having a thickness of 800 μm. The dispersion compensation element 12 is an Si substrate having a thickness of 780 μm. Namely, the dispersion compensation element 12 is formed of the same material as that of the measurement object 15 and is 20 μm thinner than the measurement object 15. The interference caused by reflection on the back surface of the measurement object 15 and reflection on the back surface of the dispersion compensation element 12 has a narrow peak width because wavelength dispersion is cancelled almost completely. Thus, the accuracy in measuring the peak position improves. As a result, the accuracy in measuring temperature, etc., improves. Full Article
mea Three-dimensional shape measuring apparatus By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT According to one embodiment, a three-dimensional shape measuring apparatus includes at least an aperture plate that is provided with a plurality of confocal apertures which are two-dimensionally arranged to have a predetermined arrangement period, and an aperture plate displacement portion that displaces the aperture plate at a constant speed in a predetermined direction perpendicular to the optical axis direction. Further, the aperture plate is provided with a cover member which is moved integrally with the aperture plate and which includes a transparent body allowing the light beams from the light source to pass therethrough and to be irradiated to the plurality of confocal apertures, and protects the plurality of confocal apertures from dust. Further, an imaging optical system, by which each of reflected light beams is guided to a photo-detector, is designed in consideration of optical properties of the whole optical system including the transparent body of the cover member. Full Article
mea Optical electrical field enhancing device and measuring apparatus equipped with the device By www.freepatentsonline.com Published On :: Tue, 16 Jun 2015 08:00:00 EDT An optical electrical field enhancing device includes: a transparent substrate having a structure of fine protrusions and recesses on the surface thereof; and a metal structure layer of fine protrusions and recesses formed on the surface of the structure of fine protrusions and recesses. The metal structure layer of fine protrusions and recesses has a structure of fine protrusions and recesses, in which the distances among adjacent protrusions are less than the distances among corresponding adjacent protrusions of the structure of fine protrusions and recesses of the transparent substrate. Full Article
mea Profile measuring apparatus, method for manufacturing structure, and structure manufacturing system By www.freepatentsonline.com Published On :: Tue, 21 Jul 2015 08:00:00 EDT There is provided a profile measuring apparatus which measures a profile of an object including: a projection unit which projects a pattern on the object from a projection direction; a measurement unit, which is displaced at a difference position for the projection unit and takes an image of the pattern from a direction different from the projection direction to measure a position on a surface of the object based on an image data obtained with the taken image; an object-rotation unit which rotates the object in two directions; and a pattern-rotation unit which is connected to the projection unit so as to be able to rotate the pattern relative to the object-rotation unit. Full Article
mea Flexible coupling means and a mechanical transmission By www.freepatentsonline.com Published On :: Tue, 24 Mar 2015 08:00:00 EDT A coupling means (10) provided with a first member (20) suitable for being fastened to a first rotary part (2) and with a second member (30) suitable for being fastened to a second rotary part (3), the first member (20) being provided with a first diaphragm (22) and the second member (30) being provided with a second diaphragm (32) that is secured to the first diaphragm (22). An emergency torque transmission device comprises at least one bayonet system including a protuberance (50) secured to one member (30) and co-operating with an angled groove (60) secured to the other member (20) by being inserted in the angled groove (60) by a thrust-and-rotation movement, in the absence of said breakage said coupling means (10) including both axial clearances in compression (70') and in translation (70″) and also circumferential clearance between each protuberance (50) and walls defining the corresponding angled groove (60). Full Article
mea Motor with torsional isolation means By www.freepatentsonline.com Published On :: Tue, 19 May 2015 08:00:00 EDT An electro-mechanical energy conversion device is provided having an armature with a central cavity. The armature is rotatably mounted in a frame. A torsion bar is positioned within the armature with one end connected to the armature and the other end connected with an energy source or consuming device. Full Article
mea System, method and apparatus for computing, monitoring, measuring, optimizing and allocating power and energy for a rod pumping system By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT A system and methods are provided for controlling a motor of a rod pumping system using previous RPMs of the motor and predicting an RPM of the motor; correcting a power factor of a motor of a rod pumping system; allocating energy consumption and allocating energy generation for a set of wells connected to an electricity meter using an amount of energy generated by each well; and generating an alert if a set of data is beyond a threshold for the set of data. Full Article
mea Method for measuring the neutron flux in the core of a nuclear reactor using a cobalt detector and associated device By www.freepatentsonline.com Published On :: Tue, 09 Sep 2014 08:00:00 EDT A method for measuring the neutron flux in the core of a nuclear reactor, the method including several steps recurrently performed at instants separated by a period, the method comprising at each given instant the following steps: acquiring a total signal by a cobalt neutron detector placed inside the core of the reactor; assessing a calibration factor representative of the delayed component of the total signal due to the presence of cobalt 60 in the neutron detector; assessing a corrected signal representative of the neutron flux at the detector from the total signal and from the calibration factor; assessing a slope representative of the time-dependent change of the calibration factor between the preceding instant and the given instant; the calibration factor at the given instant being assessed as a function of the calibration factor assessed at the preceding instant, of the slope, and of the time period separating the given instant from the preceding instant. Full Article
mea Polypeptides with permease activity By www.freepatentsonline.com Published On :: Tue, 19 May 2015 08:00:00 EDT The invention relates to a polypeptide having a mutation at one or more position corresponding to T219 of SEQ ID NO: 55, wherein the polypeptide has at least 50% sequence identity with SEQ ID NO: 55, and wherein the polypeptide has permease activity. Full Article
mea System and method of measurement data and back-up channel services By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT A system that incorporates teachings of the present disclosure may include, for example, a set top box (STB) comprising a controller programmed to receive measurement data stored in a first wireless device serving as a portable monitoring gateway that collects subscriber collected data and store and analyze the measurement data at the STB using the received measurement data received from the first wireless device and optionally from a remote server or a local storage space having stored measurement data to provide analyzed results. Other embodiments are disclosed. Full Article
mea Methods, systems, and computer readable media for measuring multicast latency By www.freepatentsonline.com Published On :: Tue, 26 May 2015 08:00:00 EDT Methods, systems, and computer readable media for measuring multicast latency are disclosed. According to one method, the method includes emulating one or more Internet protocol television (IPTV) user devices by generating channel leave and join requests. The method further includes monitoring network responses to the channel leave and join requests and calculating, during a cycle of channel leave and join requests for a user device and prior to repeating the cycle, at least one metric of latency associated with the channel leave and join requests. Full Article
mea Method for measuring air efficiency and efficacy in a combine harvester By www.freepatentsonline.com Published On :: Tue, 12 Aug 2014 08:00:00 EDT The airflow through a harvesting machine is adjusted by calculating a G-factor at a first point on an upper chaffer to determine if it is greater than 1+n, where n represents a desired factor. A blower is adjusted to reduce an airstream if the G-factor is greater than 1+n. A MOG factor is calculated if the G-factor is less than 1+n. The blower is adjusted to increase the airstream if the MOG-factor is less than 1+x, where x represents a desired factor. A MOG-factor is calculated at a second point if the MOG-factor at the point is greater than 1+x and the blower is adjusted to reduce the airstream if the MOG-factor at the second point is greater than 1+y, where y represents a desired factor or adjusted to increase the airstream if the MOG-factor at the second point is less than 1+y. Full Article
mea Forage harvester with an arrangement for measuring the harvested material throughput By www.freepatentsonline.com Published On :: Tue, 25 Nov 2014 08:00:00 EST A forage harvester has an engine which is drivingly connected to a chopper cylinder via first drive belt, and to a first end of a drive shaft of a discharge accelerator. A second end of the drive shaft of the discharge accelerator is drivingly connected to a kernel processor via a second drive belt, is arranged, in the direction of harvested material flow, between the chopper cylinder and the discharge accelerator. The discharge accelerator comprises support disks which extend radially, and paddles. The support disks are attached to a hollow shaft enclosing the drive shaft, and, a sensor is arranged between the drive shaft and the discharge accelerator for the determination of the force transmitted by the drive shaft to the discharge accelerator. Full Article