solution

High-energy-resolution inelastic X-ray scattering spectrometer at beamline 30-ID of the Advanced Photon Source

Inelastic X-ray scattering is a powerful and versatile technique for studying lattice dynamics in materials of scientific and technological importance. In this article, the design and capabilities of the momentum-resolved high-energy-resolution inelastic X-ray spectrometer (HERIX) at beamline 30-ID of the Advanced Photon Source are reported. The instrument operates at 23.724 keV and has an energy resolution of 1.3–1.7 meV. It can accommodate momentum transfers of up to 72  nm−1, at a typical X-ray flux of 4.5 × 109 photons s−1 meV−1 at the sample. A suite of in situ sample environments are provided, including high pressure, static magnetic fields and uniaxial strains, all at high or cryogenic temperatures.




solution

Solution scattering at the Life Science X-ray Scattering (LiX) beamline

This work reports the instrumentation and software implementation at the Life Science X-ray Scattering (LiX) beamline at NSLS-II in support of biomolecular solution scattering. For automated static measurements, samples are stored in PCR tubes and grouped in 18-position sample holders. Unattended operations are enabled using a six-axis robot that exchanges sample holders between a storage box and a sample handler, transporting samples from the PCR tubes to the X-ray beam for scattering measurements. The storage box has a capacity of 20 sample holders. At full capacity, the measurements on all samples last for ∼9 h. For in-line size-exclusion chromatography, the beamline-control software coordinates with a commercial high-performance liquid chromatography (HPLC) system to measure multiple samples in batch mode. The beamline can switch between static and HPLC measurements instantaneously. In all measurements, the scattering data span a wide q-range of typically 0.006–3.2 Å−1. Functionalities in the Python package py4xs have been developed to support automated data processing, including azimuthal averaging, merging data from multiple detectors, buffer scattering subtraction, data storage in HDF5 format and exporting the final data in a three-column text format that is acceptable by most data analysis tools. These functionalities have been integrated into graphical user interfaces that run in Jupyter notebooks, with hooks for external data analysis software.




solution

Shack–Hartmann wavefront sensors based on 2D refractive lens arrays and super-resolution multi-contrast X-ray imaging

Different approaches of 2D lens arrays as Shack–Hartmann sensors for hard X-rays are compared. For the first time, a combination of Shack–Hartmann sensors for hard X-rays (SHSX) with a super-resolution imaging approach to perform multi-contrast imaging is demonstrated. A diamond lens is employed as a well known test object. The interleaving approach has great potential to overcome the 2D lens array limitation given by the two-photon polymerization lithography. Finally, the radiation damage induced by continuous exposure of an SHSX prototype with a white beam was studied showing a good performance of several hours. The shape modification and influence in the final image quality are presented.




solution

Comparative study of the around-Fermi electronic structure of 5d metals and metal-oxides by means of high-resolution X-ray emission and absorption spectroscopies

The composition of occupied and unoccupied electronic states in the vicinity of Fermi energies is vital for all materials and relates to their physical, chemical and mechanical properties. This work demonstrates how the combination of resonant and non-resonant X-ray emission spectroscopies supplemented with theoretical modelling allows for quantitative analysis of electronic states in 5d transition metal and metal-oxide materials. Application of X-rays provides element selectivity that, in combination with the penetrating properties of hard X-rays, allows determination of the composition of electronic states under working conditions, i.e. non-vacuum environment. Tungsten metal and tungsten oxide are evaluated to show the capability to simultaneously assess composition of around-band-gap electronic states as well as the character and magnitude of the crystal field splitting.




solution

Estimating signal and noise of time-resolved X-ray solution scattering data at synchrotrons and XFELs

Elucidating the structural dynamics of small molecules and proteins in the liquid solution phase is essential to ensure a fundamental understanding of their reaction mechanisms. In this regard, time-resolved X-ray solution scattering (TRXSS), also known as time-resolved X-ray liquidography (TRXL), has been established as a powerful technique for obtaining the structural information of reaction intermediates and products in the liquid solution phase and is expected to be applied to a wider range of molecules in the future. A TRXL experiment is generally performed at the beamline of a synchrotron or an X-ray free-electron laser (XFEL) to provide intense and short X-ray pulses. Considering the limited opportunities to use these facilities, it is necessary to verify the plausibility of a target experiment prior to the actual experiment. For this purpose, a program has been developed, referred to as S-cube, which is short for a Solution Scattering Simulator. This code allows the routine estimation of the shape and signal-to-noise ratio (SNR) of TRXL data from known experimental parameters. Specifically, S-cube calculates the difference scattering curve and the associated quantum noise on the basis of the molecular structure of the target reactant and product, the target solvent, the energy of the pump laser pulse and the specifications of the beamline to be used. Employing a simplified form for the pair-distribution function required to calculate the solute–solvent cross term greatly increases the calculation speed as compared with a typical TRXL data analysis. Demonstrative applications of S-cube are presented, including the estimation of the expected TRXL data and SNR level for the future LCLS-II HE beamlines.




solution

Soft X-ray diffraction patterns measured by a LiF detector with sub-micrometre resolution and an ultimate dynamic range

The unique diagnostic possibilities of X-ray diffraction, small X-ray scattering and phase-contrast imaging techniques applied with high-intensity coherent X-ray synchrotron and X-ray free-electron laser radiation can only be fully realized if a sufficient dynamic range and/or spatial resolution of the detector is available. In this work, it is demonstrated that the use of lithium fluoride (LiF) as a photoluminescence (PL) imaging detector allows measuring of an X-ray diffraction image with a dynamic range of ∼107 within the sub-micrometre spatial resolution. At the PETRA III facility, the diffraction pattern created behind a circular aperture with a diameter of 5 µm irradiated by a beam with a photon energy of 500 eV was recorded on a LiF crystal. In the diffraction pattern, the accumulated dose was varied from 1.7 × 105 J cm−3 in the central maximum to 2 × 10−2 J cm−3 in the 16th maximum of diffraction fringes. The period of the last fringe was measured with 0.8 µm width. The PL response of the LiF crystal being used as a detector on the irradiation dose of 500 eV photons was evaluated. For the particular model of laser-scanning confocal microscope Carl Zeiss LSM700, used for the readout of the PL signal, the calibration dependencies on the intensity of photopumping (excitation) radiation (λ = 488 nm) and the gain have been obtained.




solution

Simulation of small-angle X-ray scattering data of biological macromolecules in solution

This article presents IMSIM, an application to simulate two-dimensional small-angle X-ray scattering patterns and, further, one-dimensional profiles from biological macromolecules in solution. IMSIM implements a statistical approach yielding two-dimensional images in TIFF, CBF or EDF format, which may be readily processed by existing data-analysis pipelines. Intensities and error estimates of one-dimensional patterns obtained from the radial average of the two-dimensional images exhibit the same statistical properties as observed with actual experimental data. With initial input on an absolute scale, [cm−1]/c[mg ml−1], the simulated data frames may also be scaled to absolute scale such that the forward scattering after subtraction of the background is proportional to the molecular weight of the solute. The effects of changes of concentration, exposure time, flux, wavelength, sample–detector distance, detector dimensions, pixel size, and the mask as well as incident beam position can be considered for the simulation. The simulated data may be used in method development, for educational purposes, and also to determine the most suitable beamline setup for a project prior to the application and use of the actual beamtime. IMSIM is available as part of the ATSAS software package (3.0.0) and is freely available for academic use (http://www.embl-hamburg.de/biosaxs/download.html).




solution

Enhancing the homogeneity of YBa2(Cu1−xFex)3O7−δ single crystals by using an Fe-added Y2O3 crucible via top-seeded solution growth

This paper reports an Fe-added Y2O3 crucible which is capable of balancing the solution spontaneously and is employed to effectively enhance the homogeneity of YBa2(Cu1−xFex)3O7−δ single crystals.




solution

High-resolution phonon energy shift measurements with the inelastic neutron spin echo technique

An energy resolution of <10 µeV for the measurement of phonon energy change is achieved with the inelastic neutron spin echo technique on a conventional neutron triple-axis spectrometer.




solution

The competition between cocrystallization and separated crystallization based on crystallization from solution

Because researchers do not understand the formation mechanism of cocrystals, the preparation of cocrystals is mostly done by trial and error. This study focuses on the cocrystal formation mechanism to improve the efficiency of cocrystal preparation.




solution

Accurate high-resolution single-crystal diffraction data from a Pilatus3 X CdTe detector

Detailed analysis of the high-flux deficiencies of pixel-array detectors leads to a protocol for the measurement of structure factors of unprecedented accuracy even for inorganic materials, and this significantly advances the prospects for experimental electron-density investigations.




solution

Hydrogen/deuterium exchange behavior in tetragonal hen egg-white lysozyme crystals affected by solution state

Neutron crystal structure analysis of hen egg-white lysozyme hydrogen/deuterium exchanged before crystallization were performed by the joint X-ray and neutron refinement. The differences in hydrogen/deuterium exchange behavior between this study and previous ones were observed.




solution

Dark-field electron holography as a recording of crystal diffraction in real space: a comparative study with high-resolution X-ray diffraction for strain analysis of MOSFETs

A detailed theoretical and experimental comparison of dark-field electron holography (DFEH) and high-resolution X-ray diffraction (HRXRD) is performed. Both techniques are being applied to measure elastic strain in an array of transistors and the role of the geometric phase is emphasized.




solution

High-resolution crystal structures of Escherichia coli FtsZ bound to GDP and GTP

Bacterial cytokinesis is mediated by the Z-ring, which is formed by the prokaryotic tubulin homolog FtsZ. Recent data indicate that the Z-ring is composed of small patches of FtsZ protofilaments that travel around the bacterial cell by treadmilling. Treadmilling involves a switch from a relaxed (R) state, favored for monomers, to a tense (T) conformation, which is favored upon association into filaments. The R conformation has been observed in numerous monomeric FtsZ crystal structures and the T conformation in Staphylococcus aureus FtsZ crystallized as assembled filaments. However, while Escherichia coli has served as a main model system for the study of the Z-ring and the associated divisome, a structure has not yet been reported for E. coli FtsZ. To address this gap, structures were determined of the E. coli FtsZ mutant FtsZ(L178E) with GDP and GTP bound to 1.35 and 1.40 Å resolution, respectively. The E. coli FtsZ(L178E) structures both crystallized as straight filaments with subunits in the R conformation. These high-resolution structures can be employed to facilitate experimental cell-division studies and their interpretation in E. coli.




solution

Stunning high-resolution NASA images available online for public exhibits

The National Aeronautics and Space Administration has made available to the public a new online collection of images that capture the excitement of planetary exploration and the journey to understand the origin and evolution of the solar system.

The post Stunning high-resolution NASA images available online for public exhibits appeared first on Smithsonian Insider.




solution

Astronomers release highest-resolution images ever of the Sun’s corona

Today, astronomers are releasing the highest-resolution images ever taken of the Sun's corona, or million-degree outer atmosphere, in an extreme-ultraviolet wavelength of light.

The post Astronomers release highest-resolution images ever of the Sun’s corona appeared first on Smithsonian Insider.




solution

Crystal and solution structures of fragments of the human leucocyte common antigen-related protein

Leucocyte common antigen-related protein (LAR) is a post-synaptic type I transmembrane receptor protein that is important for neuronal functionality and is genetically coupled to neuronal disorders such as attention deficit hyperactivity disorder (ADHD). To understand the molecular function of LAR, structural and biochemical studies of protein fragments derived from the ectodomain of human LAR have been performed. The crystal structure of a fragment encompassing the first four FNIII domains (LARFN1–4) showed a characteristic L shape. SAXS data suggested limited flexibility within LARFN1–4, while rigid-body refinement of the SAXS data using the X-ray-derived atomic model showed a smaller angle between the domains defining the L shape compared with the crystal structure. The capabilities of the individual LAR fragments to interact with heparin was examined using microscale thermophoresis and heparin-affinity chromatography. The results showed that the three N-terminal immunoglobulin domains (LARIg1–3) and the four C-terminal FNIII domains (LARFN5–8) both bound heparin, while LARFN1–4 did not. The low-molecular-weight heparin drug Innohep induced a shift in hydrodynamic volume as assessed by size-exclusion chromatography of LARIg1–3 and LARFN5–8, while the chemically defined pentameric heparin drug Arixtra did not. Together, the presented results suggest the presence of an additional heparin-binding site in human LAR.




solution

Micro-stepping Extended Focus reduces photobleaching and preserves structured illumination super-resolution features [TOOLS AND RESOURCES]

Xian Hu, Salma Jalal, Michael Sheetz, Oddmund Bakke, and Felix Margadant

Despite progress made in confocal microscopy, even fast systems still have insufficient temporal resolution for detailed live cell volume imaging, such as tracking rapid movement of membrane vesicles in three-dimensional space. Depending on the shortfall, this may result in undersampling and/or motion artifacts that ultimately limit the quality of the imaging data. By sacrificing detailed information in the Z-direction, we propose a new imaging modality that involves capturing fast "projections" from the field of depth which shortens imaging time by approximately an order of magnitude as compared to standard volumetric confocal imaging. With faster imaging, radiation exposure to the sample is reduced, resulting in less fluorophore photobleaching and potential photodamage. The implementation minimally requires two synchronized control signals that drive a piezo stage and trigger the camera exposure. The device generating the signals has been tested on spinning disk confocals and instant structured-illumination-microscopy (iSIM) microscopes. Our calibration images show that the approach provides highly repeatable and stable imaging conditions that enable photometric measurements of the acquired data, in both standard live imaging and super-resolution modes.




solution

Automated 3D light-sheet screening with high spatiotemporal resolution reveals mitotic phenotypes [TOOLS AND RESOURCES]

Björn Eismann, Teresa G. Krieger, Jürgen Beneke, Ruben Bulkescher, Lukas Adam, Holger Erfle, Carl Herrmann, Roland Eils, and Christian Conrad

3D cell cultures enable the in vitro study of dynamic biological processes such as the cell cycle, but their use in high-throughput screens remains impractical with conventional fluorescent microscopy. Here, we present a screening workflow for the automated evaluation of mitotic phenotypes in 3D cell cultures by light-sheet microscopy. After sample preparation by a liquid handling robot, cell spheroids are imaged for 24 hours in toto with a dual-view inverted selective plane illumination microscope (diSPIM) with a much improved signal-to-noise ratio, higher imaging speed, isotropic resolution and reduced light exposure compared to a spinning disc confocal microscope. A dedicated high-content image processing pipeline implements convolutional neural network based phenotype classification. We illustrate the potential of our approach by siRNA knock-down and epigenetic modification of 28 mitotic target genes for assessing their phenotypic role in mitosis. By rendering light-sheet microscopy operational for high-throughput screening applications, this workflow enables target gene characterization or drug candidate evaluation in tissue-like 3D cell culture models.




solution

Solution needed to remote connect windows phone to router




solution

Flashing ? Issue (many solutions tried) 2009 MacBook Pro




solution

New kind of interference in the case of X-ray Laue diffraction in a single crystal with uneven exit surface under the conditions of the Borrmann effect. Analytical solution

The analytical solution of the problem of X-ray spherical-wave Laue diffraction in a single crystal with a linear change of thickness on the exit surface is derived. General equations are applied to a specific case of plane-wave Laue diffraction in a thick crystal under the conditions of the Borrmann effect.




solution

Sopra Banking, Centric to deliver core banking platform and could solutions to FIs

Sopra Banking Software (SBS), a global digital banking...




solution

Automated 3D light-sheet screening with high spatiotemporal resolution reveals mitotic phenotypes

Björn Eismann
Apr 15, 2020; 0:jcs.245043v1-jcs.245043
TOOLS AND RESOURCES




solution

QuadPay, Stripe work together for instalment model solution

Payment instalment platform QuadPay has announced it is...




solution

No Single Solution for Protecting Kids From Internet Pornography

No single approach -- technical, legal, economic, or educational -- will be sufficient to protect children from online pornography.




solution

New Report Identifies Root Causes of Health Inequity in the U.S., Outlines Solutions for Communities to Advance Health Equity

The burdens of poor health and the benefits of good health and well-being are inequitably distributed in the U.S. due to factors that range from poverty and inadequate housing to structural racism and discrimination, says a new report from the National Academies of Sciences, Engineering, and Medicine.




solution

National Academy of Medicine Launches Action Collaborative to Counter Opioid Epidemic -- Public-Private Partnership Will Coordinate Initiatives Across Sectors to Drive Collective Solutions

In recognition of the need for a national coordinated and collective response to the epidemic of opioid addiction in the U.S., the National Academy of Medicine (NAM), in partnership with the Aspen Institute, launched a public-private partnership made up of more than 35 organizations representing federal, state, and local governments, health systems, associations and provider groups, health education and accrediting institutions, pharmacies, payers, industry, nonprofits, and academia.




solution

Breakthrough Solutions and Technologies Needed to Speed Cleanup of U.S. Nuclear Weapons Sites

A new report from the National Academies of Sciences, Engineering, and Medicine recommends changes in the way that the U.S. Department of Energy manages science and technology (S&T) development in order to accelerate the cleanup of radioactive waste and contaminated soil, groundwater, and facilities at U.S. nuclear weapons sites.




solution

NMI, Miura announce accreditation of M020 card payment solution with Elavon

NMI and



solution

Walmart, Ibotta partner to offer customers cash back solution

Walmart has partnered with...




solution

Need to strip HDCP from a USB 3.0 cable - any solutions?




solution

Openbravo, Adyen partner to launch retail solution

Retail and restaurant omnichannel platform Openbravo and...




solution

Optoro, Returnly partner to support retailers and brands with returns solution




solution

Smart Payment Association promotes an Instant Payment Card solution




solution

Plastic litter in the marine environment: key issues and possible solutions

International agreements to reduce plastic use are needed to address plastic litter in the marine environment, as well as increased public awareness of the problem, according to scientists at a workshop on the EU Marine Strategy Framework Directive held in Italy in 2013. The issues discussed at the workshop have been summarised in a recent research paper.




solution

Shifts in cropland and trade patterns could feed the world in 2050 — but no easy solution to future food and water security

How can we grow more crops without taking too much water away from freshwater ecosystems for irrigation? A new study indicates that it is possible to double crop production by 2050 without exceeding set limits for water extraction if more crops are grown in regions with higher rainfall and with corresponding shifts in international trade and agricultural management. However, without appropriate safeguards, and if we follow the current business-as-usual scenario, this could come at the ecological cost of converting natural land and forest into cropland. This research provides a ‘first-step’ in analysing potential trade-offs in the global food-trade-water nexus.




solution

free software sorting solution ive got driver`s from 20 years ago




solution

Old XP System Solution




solution

Cognizant to acquire global consultancy Collaborative Solutions

IT company Cognizant announced it will acquire Collaborative Solutions, a privately-held global consultancy specialising in Workday enterprise cloud applications for finance and HR.




solution

Possible solutions to local weather impacts of large wind farms

New research indicates that large-scale wind farms may influence local weather. It suggests the impact can be minimised by changing the design of the rotors or positioning wind farms in regions with high natural turbulence. These strategies could also make the farms more productive.




solution

A 50% renewable-energy smart-grid solution for the UK

A 50% renewable-energy supply, which is both profitable and secure, is possible for the UK’s electricity grid by just 2030 according to a new study. The researchers developed a plan for adapting and operating the UK’s electricity grid, designed to be flexibly controlled through smart-grid technology and to overcome uncertainties in renewable-energy supply and demand.




solution

53% enterprises in India least mature in adoption of mobility solutions, says study

53 percent of Indian enterprises were least mature in the adoption of mobility solutions whereas 17 percent of enterprises are adequately mature in their strive to adopt mobility solutions




solution

Canon India deploys mobility solutions for its 300 strong sales team

Canon India’s sales-force application (iCAN) now has mobility features that enable the sales team to attend to sales leads and generate price approval requests on the mobile which are passed onto the managers through a push notification feature.




solution

Adidas India deploys mobility solution in its 15+ franchise stores

The mobility solution brings till to the consumer in the store and enables closure of the entire billing and payment process where consumers are.




solution

Cryoviva India deploys mobility solution for its salesforce

The mobility solution has enabled the enrolment and agreement process online, followed with the customer’s digital signature and the receipt along with a confirmation SMS.




solution

12 tips for enterprises to implement remote workforce solutions

Work from home is a cultural change that requires focus on technology, security, human resources and facilities.




solution

GSK Nutritional Healthcare chooses a BT Cloud Contact solution

GSK Nutritional Healthcare chooses a BT Cloud Contact solution to improve service on vital customer help lines powered by Enghouse Interactive




solution

Government of Rajasthan selects Teradata big data solutions to improve citizen services &amp; engagement

Rajasthan to create a common data and analytics platform for all government departments across the State to collate and utilize data more effectively and efficiently, improving the delivery of citizen services with the help of Teradata solutions.




solution

Big data analytics: No big money needed as most solutions go 'freemium'

Big infrastructure and cost requirements have long kept data analytics a fiefdom of large enterprises; however, the advent of cloud tech has made it possible for SMEs to use data analytics with a fraction of a cost.