diffuse Aromatherapy Diffuser Market Set for Strong Growth: Projected to Reach $3.45 Billion by 2030 By www.emailwire.com Published On :: Fri, 01 Nov 2024 00:00:00 -0700 (EMAILWIRE.COM, November 01, 2024 ) Aromatherapy Diffuser Market was valued at USD 1.87 Bn in 2023 and is expected to reach USD 3.45 Bn by 2030, at a CAGR of 9.17 % during the forecast period Aromatherapy Diffuser Market overview: The aromatherapy diffuser market has witnessed significant growth... Full Article
diffuse Variability of visible and near-infrared (vis-NIR) diffuse spectral reflectance of cement-based solidified/ stabilized pre-treated oil-based drill cuttings By academicjournals.org Published On :: Tue, 31 Dec 2019 00:00:00 +0100 This study investigated the effects of solidification/stabilization (S/S) variables on visible and near-infrared (vis-NIR) spectral reflectance of solidified/stabilized low-temperature thermally desorbed (pre-treated) oil-based drill cuttings. Partial least squares (PLS) regression models were also developed to rapidly estimate the levels of total petroleum hydrocarbon (TPH), Cu, and Ba pres... Full Article
diffuse Scaling and merging macromolecular diffuse scattering with mdx2 By journals.iucr.org Published On :: 2024-04-12 Diffuse scattering is a promising method to gain additional insight into protein dynamics from macromolecular crystallography experiments. Bragg intensities yield the average electron density, while the diffuse scattering can be processed to obtain a three-dimensional reciprocal-space map that is further analyzed to determine correlated motion. To make diffuse scattering techniques more accessible, software for data processing called mdx2 has been created that is both convenient to use and simple to extend and modify. mdx2 is written in Python, and it interfaces with DIALS to implement self-contained data-reduction workflows. Data are stored in NeXus format for software interchange and convenient visualization. mdx2 can be run on the command line or imported as a package, for instance to encapsulate a complete workflow in a Jupyter notebook for reproducible computing and education. Here, mdx2 version 1.0 is described, a new release incorporating state-of-the-art techniques for data reduction. The implementation of a complete multi-crystal scaling and merging workflow is described, and the methods are tested using a high-redundancy data set from cubic insulin. It is shown that redundancy can be leveraged during scaling to correct systematic errors and obtain accurate and reproducible measurements of weak diffuse signals. Full Article text
diffuse Refining short-range order parameters from the three-dimensional diffuse scattering in single-crystal electron diffraction data By journals.iucr.org Published On :: 2024-01-01 Our study compares short-range order parameters refined from the diffuse scattering in single-crystal X-ray and single-crystal electron diffraction data. Nb0.84CoSb was chosen as a reference material. The correlations between neighbouring vacancies and the displacements of Sb and Co atoms were refined from the diffuse scattering using a Monte Carlo refinement in DISCUS. The difference between the Sb and Co displacements refined from the diffuse scattering and the Sb and Co displacements refined from the Bragg reflections in single-crystal X-ray diffraction data is 0.012 (7) Å for the refinement on diffuse scattering in single-crystal X-ray diffraction data and 0.03 (2) Å for the refinement on the diffuse scattering in single-crystal electron diffraction data. As electron diffraction requires much smaller crystals than X-ray diffraction, this opens up the possibility of refining short-range order parameters in many technologically relevant materials for which no crystals large enough for single-crystal X-ray diffraction are available. Full Article text
diffuse Catching Up with Org Junkie #20 ~ Nov/Dec 2021 Favorites: Advent, Car Diffuser & Hot Chocolate By orgjunkie.com Published On :: Sat, 04 Dec 2021 23:29:37 +0000 Welcome to my Nov/Dec 2021 Favorites! Hello! Can you believe we are well into December already? Instead of simply doing a favorites list of last month, I’m going to combine and share my Nov/Dec 2021 favorites into one post. At this time of the year I hope you aren’t feeling stress but instead I pray ... Read More about Catching Up with Org Junkie #20 ~ Nov/Dec 2021 Favorites: Advent, Car Diffuser & Hot Chocolate The post Catching Up with Org Junkie #20 ~ Nov/Dec 2021 Favorites: Advent, Car Diffuser & Hot Chocolate appeared first on I'm an Organizing Junkie. Full Article Favorite Things My Life
diffuse Invi Air: Linear Air Diffuser By www.achrnews.com Published On :: Sun, 10 Nov 2024 20:00:26 -0500 Using a smart composite material instead of traditional aluminum, Invi Air's diffusers reduce condensation by up to 95%, leading to improved HVAC system efficiency and long-term durability. Full Article
diffuse International Metabolic Prognostic Index Is Superior to Other Metabolic Tumor Volume-Based Prognostication Methods in a Real-Life Cohort of Diffuse Large B-Cell Lymphoma By jnm.snmjournals.org Published On :: 2024-11-07T04:28:32-08:00 Visual Abstract Full Article
diffuse Validation of an Artificial Intelligence-Based Prediction Model Using 5 External PET/CT Datasets of Diffuse Large B-Cell Lymphoma By jnm.snmjournals.org Published On :: 2024-11-01T04:25:31-07:00 The aim of this study was to validate a previously developed deep learning model in 5 independent clinical trials. The predictive performance of this model was compared with the international prognostic index (IPI) and 2 models incorporating radiomic PET/CT features (clinical PET and PET models). Methods: In total, 1,132 diffuse large B-cell lymphoma patients were included: 296 for training and 836 for external validation. The primary outcome was 2-y time to progression. The deep learning model was trained on maximum-intensity projections from PET/CT scans. The clinical PET model included metabolic tumor volume, maximum distance from the bulkiest lesion to another lesion, SUVpeak, age, and performance status. The PET model included metabolic tumor volume, maximum distance from the bulkiest lesion to another lesion, and SUVpeak. Model performance was assessed using the area under the curve (AUC) and Kaplan–Meier curves. Results: The IPI yielded an AUC of 0.60 on all external data. The deep learning model yielded a significantly higher AUC of 0.66 (P < 0.01). For each individual clinical trial, the model was consistently better than IPI. Radiomic model AUCs remained higher for all clinical trials. The deep learning and clinical PET models showed equivalent performance (AUC, 0.69; P > 0.05). The PET model yielded the highest AUC of all models (AUC, 0.71; P < 0.05). Conclusion: The deep learning model predicted outcome in all trials with a higher performance than IPI and better survival curve separation. This model can predict treatment outcome in diffuse large B-cell lymphoma without tumor delineation but at the cost of a lower prognostic performance than with radiomics. Full Article
diffuse Utility of Early Postoperative DWI to Assess the Extent of Resection of Adult-Type World Health Organization Grade 2 and 3 Diffuse Gliomas [CLINICAL PRACTICE] By www.ajnr.org Published On :: 2024-11-07T15:14:12-08:00 BACKGROUND AND PURPOSE: World Health Organization (WHO) grade 2 and 3 diffuse gliomas account for approximately 5% of primary brain tumors. They are invasive and infiltrative tumors and have considerable morbidity, causing progressive neurologic deterioration. The mean survival time is <10 years from diagnosis. Surgical debulking represents first-line management. The extent of resection is associated with progression-free and overall survival. Radiologic assessment of the extent of resection is challenging. This can be underestimated on early postoperative MRI, meaning that accurate assessment may be achieved only on delayed follow-up imaging. We hypothesized that DWI may help facilitate more reliable estimates of the extent of resection on early postoperative MRI. This study aimed to assess the utility of DWI in early postoperative MRI to evaluate the extent of resection. MATERIALS AND METHODS: A single-center observational cohort study was performed. All patients with histologically confirmed WHO grade 2 and 3 gliomas managed with surgical debulking between January 2015 and December 2020 were identified. Preoperative, early postoperative, and follow-up imaging were reviewed independently by 2 consultant neuroradiologists. The extent of resection was estimated with and without DWI sequences for each case. RESULTS: Two hundred twenty-four patients with WHO grade 2 and 3 gliomas were managed with surgical debulking between 2015 and 2020. DWI was not performed on early postoperative MRI in 2 patients. With the use of DWI, the extent of resection was upgraded in 30% of cases (n = 66/222) and classified as "complete" or "supramaximal" in 58% of these patients (n = 38/66). In cases in which the extent of resection was upgraded with the use of DWI, signal abnormality was stable or reduced at follow-up in 78% (n = 49/63). In cases with worsening signal abnormality, 64% were deemed to be secondary to adjuvant radiation therapy (n = 9/14). Eight percent (n = 5/63) of patients with an increased estimated extent of resection using DWI demonstrated signal progression attributed to true disease progression at follow-up. CONCLUSIONS: DWI is a helpful and reliable adjunct in differentiating residual tumor from marginal ischemia in early postoperative MRI in WHO grade 2 and 3 diffuse gliomas and increases the accuracy in assessing the extent of resection. It should be used routinely in these cases. Full Article
diffuse PD-L1+ diffuse large B-cell lymphoma with extremely high mutational burden and microsatellite instability due to acquired PMS2 mutation [RESEARCH REPORT] By molecularcasestudies.cshlp.org Published On :: 2024-01-10T08:13:38-08:00 We present a unique case of a single patient presenting with two mutationally distinct, PD-L1+ diffuse large B-cell lymphomas (DLBCLs). One of these DLBCLs demonstrated exceptionally high mutational burden (eight disease-associated variants and 41 variants of undetermined significance) with microsatellite instability (MSI) and an acquired PMS2 mutation with loss of PMS2 protein expression, detected postchemotherapy. This report, while highlighting the extent of possible tumor heterogeneity across separate clonal expansions as well as possible syndromic B-cell neoplasia, supports the notion that, although rare, PD-L1 expression and associated states permissive of high mutational burden (such as mismatch repair gene loss of function/MSI) should be more routinely considered in DLBCLs. Appropriate testing may be predictive of outcome and inform the utility of targeted therapy in these genetically diverse and historically treatment-refractory malignancies. Full Article
diffuse Leukemic presentation and progressive genomic alterations of MCD/C5 diffuse large B-cell lymphoma (DLBCL) [RESEARCH ARTICLE] By molecularcasestudies.cshlp.org Published On :: 2024-01-10T08:13:38-08:00 Diffuse large B-cell lymphoma (DLBCL) is a heterogenous group of lymphoid malignancies. Based on gene expression profiling, it has been subdivided into germinal center (GC)-derived and activated B-cell (ABC) types. Advances in molecular methodologies have further refined the subclassification of DLBCL, based on recurrent genetic abnormalities. Here, we describe a distinct case of DLBCL that presented in leukemic form. DNA sequencing targeting 275 genes revealed pathogenically relevant mutations of CD79B, MyD88, TP53, TBL1XR1, and PIM1 genes, indicating that this lymphoma would be best classified as MCD/C5 DLBCL, an ABC subtype. Despite an initial good clinical response to BTK inhibitor ibrutinib, anti-CD20 antibody rituxan, alkylating agent bendamustine, and hematopoietic stem-cell transplant, the lymphoma relapsed, accompanied by morphologic and molecular evidence of disease progression. Specifically, the recurrent tumor developed loss of TP53 heterozygosity (LOH) and additional chromosomal changes central to ABC DLBCL pathogenesis, such as PRDM1 loss. Acquired resistance to ibrutinib and rituxan was indicated by the emergence of BTK and FOXO1 mutations, respectively, as well as apparent activation of alternative cell-activation pathways, through copy-number alterations (CNAs), detected by high-resolution chromosomal microarrays. In vitro, studies of relapsed lymphoma cells confirmed resistance to standard BTK inhibitors but sensitivity to vecabrutinib, a noncovalent inhibitor active against both wild-type as well as mutated BTK. In summary, we provide in-depth molecular characterization of a de novo leukemic DLBCL and discuss mechanisms that may have contributed to the lymphoma establishment, progression, and development of drug resistance. Full Article
diffuse An elderly woman with acute respiratory failure and diffuse pulmonary changes By breathe.ersjournals.com Published On :: 2024-11-12T00:25:08-08:00 Full Article
diffuse Development and Simulation of Annular Flow Photoreactors: Integration of Light-Diffusing Fibers as optical diffusers with Laser Diodes By pubs.rsc.org Published On :: React. Chem. Eng., 2024, Accepted ManuscriptDOI: 10.1039/D4RE00400K, Paper Open Access   This article is licensed under a Creative Commons Attribution 3.0 Unported Licence.Sergio Carrillo De Hert, Rafael Lopez-Rodriguez, Michael Di Maso, Jonathan McMullen, Steven FergusonContinuous flow chemical photoreactors have emerged as a highly attractive platform, garnering considerable attention in both industry and academia. Utilizing thin channels, these reactors offer a promising solution for achieving...The content of this RSS Feed (c) The Royal Society of Chemistry Full Article
diffuse How to diffuse intergenerational tensions By www.financialexpress.com Published On :: 2020-03-16T08:16:00+05:30 The millennials are accustomed to having things at the click of a mouse. Want to watch a movie? Access Netflix. Want to plan a holiday? Do so on Makemytrip. Want to shop? Buy almost anything under the sun, any time, on Amazon or Flipkart. Want beauty treatment? Call Urbanclap. Want a date? Simply swipe right! Full Article Lifestyle
diffuse Diffuse scattering and partial disorder in complex structures By journals.iucr.org Published On :: This review discusses the state of the field of single-crystal diffuse scattering (SCDS), including detectors, data collection and the modelling techniques. High quality, three-dimensional volumes of SCDS data can now be collected at synchrotron light sources, allowing increasingly detailed and quantitative analyses to be undertaken. Full Article text
diffuse Ultrafast calculation of diffuse scattering from atomistic models By scripts.iucr.org Published On :: 2019-01-01 Diffuse scattering is a rich source of information about disorder in crystalline materials, which can be modelled using atomistic techniques such as Monte Carlo and molecular dynamics simulations. Modern X-ray and neutron scattering instruments can rapidly measure large volumes of diffuse-scattering data. Unfortunately, current algorithms for atomistic diffuse-scattering calculations are too slow to model large data sets completely, because the fast Fourier transform (FFT) algorithm has long been considered unsuitable for such calculations [Butler & Welberry (1992). J. Appl. Cryst. 25, 391–399]. Here, a new approach is presented for ultrafast calculation of atomistic diffuse-scattering patterns. It is shown that the FFT can actually be used to perform such calculations rapidly, and that a fast method based on sampling theory can be used to reduce high-frequency noise in the calculations. These algorithms are benchmarked using realistic examples of compositional, magnetic and displacive disorder. They accelerate the calculations by a factor of at least 102, making refinement of atomistic models to large diffuse-scattering volumes practical. Full Article text
diffuse Tired of Those Complicated "Smart" Home Gadgets? Try this User-Friendly Aroma Diffuser By www.24-7pressrelease.com Published On :: Tue, 07 Nov 2017 07:00:00 GMT VASO has smart sensors to ensure unique add-water-to-start function. The built-in natural sounds are kind of "white noise", which helps to improve sleeping & creativity. All the functions are designed for easily use, rather than "smart" concept. Full Article
diffuse Diffuser mounting flange By www.freepatentsonline.com Published On :: Tue, 12 May 2015 08:00:00 EDT A mounting flange for attaching an HVAC air diffuser terminal in an opening in a floor or other mounting surface. The mounting flange includes a trim ring and a flange clip. The flange clip is adjustably and movably received in a slot defined a side of the trim ring. A pawl on the flange clip engages with ratchets defined in a surface of the trim ring adjacent to the slot to maintain the flange clip in selected position relative the underside of a floor. The air diffuser terminal is secured in the floor opening between gripping surfaces on the flange clip and the trim ring. An optional screw operably connects the flange clip with the trim ring so that the diffuser may be securely tightened in the floor opening. Full Article
diffuse Bladed coal diffuser and coal line balancing device By www.freepatentsonline.com Published On :: Tue, 31 Mar 2015 08:00:00 EDT A coal nozzle assembly for a pulverized coal burner includes a diffuser. A flow conditioner also may be used with the assembly. The assembly conditions the coal/air flow before the coal/air flow is introduced to the furnace. The flow conditioner directs the coal into the diffuser where it is swirled to form a fuel rich outer ring disposed about an air rich inner portion before the fuel is delivered to the coal nozzle. Full Article
diffuse Attachment structure for adjustable air diffuser By www.freepatentsonline.com Published On :: Tue, 30 Dec 2014 08:00:00 EST An adjustable air diffuser is disposed in an airflow channel into which a travelling wind is directed through an opening provided in a bumper face. The diffuser opens and closes the channel by movable louver blades driven by an actuator. An upper part of the diffuser is disposed to face a rear wall of the bumper face and is attached to a bumper beam extending along a vehicle width direction. A lower part of the diffuser is attached to a vehicle body structural member. The attachment structure includes a column that is disposed behind the adjustable air diffuser. A lower end of the column is attached to a lower end of the adjustable air diffuser. Weak portions are provided on the column such that the column breaks when the column interferes with another member behind the column. Full Article
diffuse Diffuser/emulsifier for aquaculture applications By www.freepatentsonline.com Published On :: Tue, 19 May 2015 08:00:00 EDT A method of treatment of water in an aquatic environment. Water is first pumped from a reservoir to a first mixing station. An inert gas is introduced into the pumped water at the first mixing station to provide inert gas saturated water, which inert gas saturated water will displace undesired gasses in the water in the reservoir. The inert gas saturated water is then pumped to a sparging column such that the inert gas and undesired gasses will be released from the inert gas saturated water to provide depleted water. Full Article
diffuse Floating vessel for servicing air diffusers By www.freepatentsonline.com Published On :: Tue, 05 May 2015 08:00:00 EDT A catamaran type vessel for use in a wastewater facility for servicing submerged air diffusers is disclosed. The vessel has spaced apart pontoon having an A-frame spanning between the upper decks of the pontoon and connecting the pontoons. A hook connected to a winch is secured to a cross header above the space between the pontoons. The hook is lowered into water and lifts an air header, to which the air diffusers are connected. An air diffuser is then pulled on the pontoons and serviced. The vessel is then propelled to a position to service other air diffusers in the pontoon. Full Article
diffuse METHOD AND APPARATUS FOR DIFFUSE COMBUSTION OF PREMIX By www.freepatentsonline.com Published On :: Thu, 15 Jun 2017 08:00:00 EDT A method directs fuel-oxidant premix into a reaction zone through a first total premix inlet flow area, and causes the premix to combust and form a stable flame projecting into a process chamber through an outlet from the reaction zone. At a time when the process chamber has a temperature at or above an auto-ignition temperature of the fuel, the flame is blown off to initiate diffuse combustion in the process chamber without a stable flame. The flame is blown off by directing the premix into the reaction zone through a second total premix inlet flow area greater than the first total premix inlet flow area. Full Article
diffuse OPTICAL DIFFUSER By www.freepatentsonline.com Published On :: Thu, 29 Jun 2017 08:00:00 EDT A device includes an optical delivery fiber having a core having a first inside diameter joined to a capillary having an outer surface and a capillary tube having an inner surface. The capillary tube has a second inside diameter in the region of the joining to the optical delivery fiber. The second inside diameter is less than the first inside diameter of the delivery fiber. Full Article
diffuse Waste Water Diffuser By www.freepatentsonline.com Published On :: Thu, 29 Jun 2017 08:00:00 EDT This application claims a system for the distribution of waste water. The invention allows water to drain from a source into the invention, where the water is distributed and diffused through a collection of outlets. Thus a large amount of water can be distributed over a large area so that the environment can more easily absorb the water and the flow of water does not cause erosion. The preferred embodiment of the invention optionally may include one or more filters to remove substances from the water before distribution. Full Article
diffuse Jupiter’s ravenous past might help explain its diffuse, hazy core By www.pbs.org Published On :: A computer simulation suggests that a massive collision may have caused Jupiter’s core to shatter into a gassy, borderless cloud. Full Article
diffuse Combined Visual and Semi-quantitative Evaluation Improves Outcome Prediction by Early Mid-treatment 18F-fluoro-deoxi-glucose Positron Emission Tomography in Diffuse Large B-cell Lymphoma. By jnm.snmjournals.org Published On :: 2019-11-22T10:43:33-08:00 The purpose of this study was to assess the predictive and prognostic value of interim FDG PET (iPET) in evaluating early response to immuno-chemotherapy after two cycles (PET-2) in diffuse large B-cell lymphoma (DLBCL) by applying two different methods of interpretation: the Deauville visual five-point scale (5-PS) and a change in standardised uptake value by semi-quantitative evaluation. Methods: 145 patients with newly diagnosed DLBCL underwent pre-treatment PET (PET-0) and PET-2 assessment. PET-2 was classified according to both the visual 5-PS and percentage SUV changes (SUV). Receiver operating characteristic (ROC) analysis was performed to compare the accuracy of the two methods for predicting progression-free survival (PFS). Survival estimates, based on each method separately and combined, were calculated for iPET-positive (iPET+) and iPET-negative (iPET–) groups and compared. Results: Both with visual and SUV-based evaluations significant differences were found between the PFS of iPET– and iPET+ patient groups (p<0.001). Visually the best negative (NPV) and positive predictive value (PPV) occurred when iPET was defined as positive if Deauville score 4-5 (89% and 59%, respectively). Using the 66% SUV cut-off value, reported previously, NPV and PPV were 80 and 76%, respectively. SUV at 48.9% cut-off point, reported for the first time here, produced 100% specificity along with the highest sensitivity (24%). Visual and semi-quantitative SUV<48.9% assessment of each PET-2 gave the same PET-2 classification (positive or negative) in 70% (102/145) of all patients. This combined classification delivered NPV and PPV of 89% and 100% respectively, and all iPET+ patients failed to achieve or remain in remission. Conclusion: In this large consistently treated and assessed series of DLBCL, iPET had good prognostic value interpreted either visually or semi-quantitatively. We determined that the most effective SUV cut-off was at 48.9%, and that when combined with visual 5-PS assessment, a positive PET-2 was highly predictive of treatment failure. Full Article
diffuse Interim PET evaluation in diffuse large B-cell lymphoma employing published recommendations: Comparison of the Deauville 5-point scale and the {Delta}SUVmax method By jnm.snmjournals.org Published On :: 2020-05-08T13:18:58-07:00 The value of interim 18F-fluorodeoxyglucose positron emission tomography (iPET) guided treatment decisions in patients with diffuse large B-cell lymphoma (DLBCL) has been the subject of much debate. This investigation focuses on a comparison of the Deauville score and the deltaSUVmax (SUVmax) approach – two methods to assess early metabolic response to standard chemotherapy in DLBCL. Methods: Of 609 DLBCL patients participating in the Positron Emission Tomography-guided Therapy of Aggressive non-Hodgkin Lymphomas (PETAL) trial, iPET scans of 596 patients originally evaluated using the SUVmax method were available for post-hoc assessment of the Deauville score. A commonly used definition of an unfavorable iPET result according to the Deauville score is an uptake greater than that of the liver, whereas an unfavorable iPET scan with regard to the SUVmax approach is characterized as a relative reduction of the maximum standardized uptake value between baseline and iPET staging of less than or equal to 66%. We investigated the two methods’ correlation and concordance by Spearman’s rank correlation coefficient and the agreement in classification, respectively. We further used Kaplan-Meier curves and Cox regression to assess differences in survival between patient subgroups defined by the pre-specified cut-offs. Time-dependent receiver operating curve analysis provided information on the methods’ respective discrimination performance. Results: Deauville score and SUVmax approach differed in their iPET-based prognosis. The SUVmax approach outperformed the Deauville score in terms of discrimination performance – most likely due to a high number of false-positive decisions by the Deauville score. Cut-off-independent discrimination performance remained low for both methods, but cut-off-related analyses showed promising results. Both favored the SUVmax approach, e.g. for the segregation by iPET response, where the event-free survival hazard ratio was 3.14 (95% confidence interval (CI): 2.22 – 4.46) for SUVmax and 1.70 (95% CI: 1.29 – 2.24) for the Deauville score. Conclusion: When considering treatment intensification, the currently used Deauville score cut-off of an uptake above that of the liver seems to be inappropriate and associated with potential harm for DLBCL patients. The SUVmax criterion of a relative reduction of the maximum standardized uptake value of less than or equal to 66% should be considered as an alternative. Full Article
diffuse Die diffuse Nephritis und die Entzündung im Allgemeinen / von E. Aufrecht. By feedproxy.google.com Published On :: Berlin : G. Reimer, 1879. Full Article
diffuse An increase in MYC copy number has a progressive negative prognostic impact in patients with diffuse large B-cell and high-grade lymphoma, who may benefit from intensified treatment regimens By www.haematologica.org Published On :: 2020-05-01T00:05:42-07:00 MYC translocations, a hallmark of Burkitt lymphoma, occur in 5-15% of diffuse large B-cell lymphoma, and have a negative prognostic impact. Numerical aberrations of MYC have also been detected in these patients, but their incidence and prognostic role are still controversial. We analyzed the clinical impact of MYC increased copy number on 385 patients with diffuse large B-cell lymphoma screened at diagnosis for MYC, BCL2, and BCL6 rearrangements. We enumerated the number of MYC copies, defining as amplified those cases with an uncountable number of extra-copies. The prevalence of MYC translocation, increased copy number and amplification was 8.8%, 15%, and 1%, respectively. Patients with 3 or 4 gene copies, accounting for more than 60% of patients with MYC copy number changes, had a more favorable outcome compared to patients with >4 copies or translocation of MYC, and were not influenced by the type of treatment received as first-line. Stratification according to the number of MYC extra-copies showed a negative correlation between an increasing number of copies and survival. Patients with >7 copies or the amplification of MYC had the poorest prognosis. Patients with >4 copies of MYC showed a similar, trending towards worse prognosis compared to patients with MYC translocation. The survival of patients with >4 copies, translocation or amplification of MYC seemed to be superior if intensive treatments were used. Our study underlines the importance of fluorescence in situ hybridization testing at diagnosis of diffuse large B-cell lymphoma to detect the rather frequent and clinically significant numerical aberrations of MYC. Full Article
diffuse CXCR4 upregulation is an indicator of sensitivity to B-cell receptor/PI3K blockade and a potential resistance mechanism in B-cell receptor-dependent diffuse large B-cell lymphomas By www.haematologica.org Published On :: 2020-05-01T00:05:42-07:00 B-cell receptor (BCR) signaling pathway components represent promising treatment targets in multiple B-cell malignancies including diffuse large B-cell lymphoma (DLBCL). In in vitro and in vivo model systems, a subset of DLBCLs depend upon BCR survival signals and respond to proximal BCR/phosphoinositide 3 kinase (PI3K) blockade. However, single-agent BCR pathway inhibitors have had more limited activity in patients with DLBCL, underscoring the need for indicators of sensitivity to BCR blockade and insights into potential resistance mechanisms. Here, we report highly significant transcriptional upregulation of C-X-C chemokine receptor 4 (CXCR4) in BCR-dependent DLBCL cell lines and primary tumors following chemical spleen tyrosine kinase (SYK) inhibition, molecular SYK depletion or chemical PI3K blockade. SYK or PI3K inhibition also selectively upregulated cell surface CXCR4 protein expression in BCR-dependent DLBCLs. CXCR4 expression was directly modulated by fork-head box O1 via the PI3K/protein kinase B/forkhead box O1 signaling axis. Following chemical SYK inhibition, all BCR-dependent DLBCLs exhibited significantly increased stromal cell-derived factor-1α (SDF-1α) induced chemotaxis, consistent with the role of CXCR4 signaling in B-cell migration. Select PI3K isoform inhibitors also augmented SDF-1α induced chemotaxis. These data define CXCR4 upregulation as an indicator of sensitivity to BCR/PI3K blockade and identify CXCR4 signaling as a potential resistance mechanism in BCR-dependent DLBCLs. Full Article
diffuse Advanced ADC Histogram, Perfusion, and Permeability Metrics Show an Association with Survival and Pseudoprogression in Newly Diagnosed Diffuse Intrinsic Pontine Glioma: A Report from the Pediatric Brain Tumor Consortium [FUNCTIONAL] By www.ajnr.org Published On :: 2020-04-09T06:30:48-07:00 BACKGROUND AND PURPOSE: Diffuse intrinsic pontine glioma is a lethal childhood brain cancer with dismal prognosis and MR imaging is the primary methodology used for diagnosis and monitoring. Our aim was to determine whether advanced diffusion, perfusion, and permeability MR imaging metrics predict survival and pseudoprogression in children with newly diagnosed diffuse intrinsic pontine glioma. MATERIALS AND METHODS: A clinical trial using the poly (adenosine diphosphate ribose) polymerase (PARP) inhibitor veliparib concurrently with radiation therapy, followed by maintenance therapy with veliparib + temozolomide, in children with diffuse intrinsic pontine glioma was conducted by the Pediatric Brain Tumor Consortium. Standard MR imaging, DWI, dynamic contrast-enhanced perfusion, and DSC perfusion were performed at baseline and approximately every 2 months throughout treatment. ADC histogram metrics of T2-weighted FLAIR and enhancing tumor volume, dynamic contrast-enhanced permeability metrics for enhancing tumors, and tumor relative CBV from DSC perfusion MR imaging were calculated. Baseline values, post-radiation therapy changes, and longitudinal trends for all metrics were evaluated for associations with survival and pseudoprogression. RESULTS: Fifty children were evaluable for survival analyses. Higher baseline relative CBV was associated with shorter progression-free survival (P = .02, Q = 0.089) and overall survival (P = .006, Q = 0.055). Associations of higher baseline mean transfer constant from the blood plasma into the extravascular extracellular space with shorter progression-free survival (P = .03, Q = 0.105) and overall survival (P = .03, Q = 0.102) trended toward significance. An increase in relative CBV with time was associated with shorter progression-free survival (P < .001, Q < 0.001) and overall survival (P = .004, Q = 0.043). Associations of longitudinal mean extravascular extracellular volume fraction with progression-free survival (P = .03, Q = 0.104) and overall survival (P = .03, Q = 0.105) and maximum transfer constant from the blood plasma into the extravascular extracellular space with progression-free survival (P = .03, Q = 0.102) trended toward significance. Greater increases with time were associated with worse outcomes. True radiologic progression showed greater post-radiation therapy decreases in mode_ADC_FLAIR compared with pseudoprogression (means, –268.15 versus –26.11, P = .01.) CONCLUSIONS: ADC histogram, perfusion, and permeability MR imaging metrics in diffuse intrinsic pontine glioma are useful in predicting survival and pseudoprogression. Full Article
diffuse Identification of gene modules associated with survival of diffuse large B-cell lymphoma treated with CHOP-based chemotherapy By feeds.nature.com Published On :: 2020-02-11 Full Article
diffuse Dystrophic calcification and heterotopic ossification in fibrocartilaginous tissues of the spine in diffuse idiopathic skeletal hyperostosis (DISH) By feeds.nature.com Published On :: 2020-04-02 Full Article
diffuse [ASAP] Targeting ALK2: An Open Science Approach to Developing Therapeutics for the Treatment of Diffuse Intrinsic Pontine Glioma By feedproxy.google.com Published On :: Tue, 05 May 2020 04:00:00 GMT Journal of Medicinal ChemistryDOI: 10.1021/acs.jmedchem.0c00395 Full Article
diffuse Oxaliplatin and [Pt(R,R-DACH)(panobinostat-2H)] show nanomolar cytotoxicity towards diffuse intrinsic pontine glioma (DIPG) By feeds.rsc.org Published On :: Dalton Trans., 2020, 49,5703-5710DOI: 10.1039/C9DT04862F, Paper Open Access   This article is licensed under a Creative Commons Attribution 3.0 Unported Licence.Marie H. C. Boulet, Laura K. Marsh, Alison Howarth, Alice Woolman, Nicola J. FarrerOxaliplatin and the platinum(II) panobinostat complex (2) demonstrate nanomolar cytotoxicity towards diffuse intrinsic pontine glioma cells (DIPG); with 2 exhibiting improved solubility in comparison to panobinostat.The content of this RSS Feed (c) The Royal Society of Chemistry Full Article
diffuse Diffuse lung diseases [electronic resource] : clinical features, pathology, HRCT / editors, Mario Maffessanti & Giorgia Dalpiaz ; authors A. Cancellieri [and others] By darius.uleth.ca Published On :: Milan ; New York : Springer, 2006 Full Article
diffuse Diffuse degassing and the hydrothermal system at masaya volcano, nicaragua By digital.lib.usf.edu Published On :: Sat, 15 Feb 2014 19:15:29 -0400 Full Article