health and food FDG-PET/CT identifies predictors of survival in patients with locally advanced cervical carcinoma and para-aortic lymph node involvement to increase treatment By jnm.snmjournals.org Published On :: 2020-02-07T14:31:42-08:00 Introduction: To use positron emission tomography coupled with computed tomography (18FDG-PET/CT) to identify a high-risk subgroup requiring therapeutic intensification among patients with locally advanced cervical cancer (LACC) and para-aortic lymph node (PALN) involvement. Methods: In this retrospective multicentric study, patients with LACC and PALN involvement concurrently treated with chemoradiotherapy and extended-field radiotherapy (EFR) between 2006 and 2016 were included. A senior nuclear medicine specialist in PET for gynaecologic oncology reviewed all 18FDG-PET/CT scans. Metabolic parameters including maximum standardised uptake value (SUVmax), metabolic tumour volume (MTV) and total lesion glycolysis (TLG) were determined for the primary tumour, pelvic lymph nodes and PALN. Associations between these parameters and overall survival (OS) were assessed with Cox's proportional hazards model. Results: Sixty-eight patients were enrolled in the study. Three-year OS was 55.5% (95% CI (40.8-68.0)). When adjusted for age, stage and histology, pelvic lymph node TLG, PALN TLG and PALN SUVmax were significantly associated with OS (p<0.005). Conclusion: FDG-PET/CT was able to identify predictors of survival in the homogeneous subgroup of patients with LACC and PALN involvement, thus allowing therapeutic intensification to be proposed. Full Article
health and food Imaging the Distribution of Gastrin Releasing Peptide Receptors in Cancer By jnm.snmjournals.org Published On :: 2020-02-14T14:01:21-08:00 Targeting tumor-expressed receptors using selective molecules for diagnostic, therapeutic or both diagnostic and therapeutic (theragnostic) purposes is a promising approach in oncological applications. Such approaches have increased significantly over the past decade. Peptides such as gastrin-releasing peptide receptors (GRPR) targeting radiopharmaceuticals are small molecules with fast blood clearance and urinary excretion. They demonstrate good tissue diffusion, low immunogenicity, and highly selective binding to their target cell-surface receptors. They are also easily produced. GRPR, part of the bombesin (BBN) family, are overexpressed in many tumors, including breast and prostate cancer, and therefore represent an attractive target for future development. Full Article
health and food Data-driven motion detection and event-by-event correction for brain PET: Comparison with Vicra By jnm.snmjournals.org Published On :: 2020-02-14T14:01:21-08:00 Head motion degrades image quality and causes erroneous parameter estimates in tracer kinetic modeling in brain PET studies. Existing motion correction methods include frame-based image-registration (FIR) and correction using real-time hardware-based motion tracking (HMT) information. However, FIR cannot correct for motion within one predefined scan period while HMT is not readily available in the clinic since it typically requires attaching a tracking device to the patient. In this study, we propose a motion correction framework with a data-driven algorithm, i.e., using the PET raw data itself, to address these limitations. Methods: We propose a data-driven algorithm, Centroid of Distribution (COD), to detect head motion. In COD, the central coordinates of the line of response (LOR) of all events are averaged over 1-sec intervals to generate a COD trace. A point-to-point change in the COD trace in one direction that exceeded a user-defined threshold was defined as a time point of head motion, which was followed by manually adding additional motion time points. All the frames defined by such time points were reconstructed without attenuation correction and rigidly registered to a reference frame. The resulting transformation matrices were then used to perform the final motion compensated reconstruction. We applied the new COD framework to 23 human dynamic datasets, all containing large head motions, with 18F-FDG (N = 13) and 11C-UCB-J (N = 10), and compared its performance with FIR and with HMT using the Vicra, which can be considered as the "gold standard". Results: The COD method yielded 1.0±3.2% (mean ± standard deviation across all subjects and 12 grey matter regions) SUV difference for 18F-FDG (3.7±5.4% for 11C-UCB-J) compared to HMT while no motion correction (NMC) and FIR yielded -15.7±12.2% (-20.5±15.8%) and -4.7±6.9% (-6.2±11.0%), respectively. For 18F-FDG dynamic studies, COD yielded differences of 3.6±10.9% in Ki value as compared to HMT, while NMC and FIR yielded -18.0±39.2% and -2.6±19.8%, respectively. For 11C-UCB-J, COD yielded 3.7±5.2% differences in VT compared to HMT, while NMC and FIR yielded -20.0±12.5% and -5.3±9.4%, respectively. Conclusion: The proposed COD-based data-driven motion correction method outperformed FIR and achieved comparable or even better performance as compared to the Vicra HMT method in both static and dynamic studies. Full Article
health and food Clinical evaluation of a data-driven respiratory gating algorithm for whole-body positron emission tomography with continuous bed motion By jnm.snmjournals.org Published On :: 2020-02-14T14:01:21-08:00 Respiratory gating is the standard to overcome respiration effects degrading image quality in positron emission tomography (PET). Data-driven gating (DDG) using signals derived from PET raw data are promising alternatives to gating approaches requiring additional hardware. However, continuous bed motion (CBM) scans require dedicated DDG approaches for axially-extended PET, compared to DDG for conventional step-and-shoot scans. In this study, a CBM-capable DDG algorithm was investigated in a clinical cohort, comparing it to hardware-based gating using gated and fully motion-corrected reconstructions. Methods: 56 patients with suspected malignancies in thorax or abdomen underwent whole-body 18F-FDG CBM-PET/CT imaging using DDG and hardware-based respiratory gating (pressure-sensitive belt gating, BG). Correlation analyses were performed on both gating signals. Besides static reconstructions, BG and DDG were used for optimally-gated PET (BG-OG, DDG-OG) and fully motion-corrected PET (elastic motion correction; BG-EMOCO, DDG-EMOCO). Metabolic volumes, SUVmax and SUVmean of lesions were compared amongst the reconstructions. Additionally, the quality of lesion delineation in different PET reconstructions was independently evaluated by three experts. Results: Global correlation coefficients between BG and DDG signals amounted to 0.48±0.11, peaking at 0.89±0.07 when scanning the kidney and liver region. In total, 196 lesions were analyzed. SUV measurements were significantly higher in BG-OG, DDG-OG, BG-EMOCO and DDG-EMOCO compared to static images (P<0.001; median SUVmax: static, 14.3±13.4; BG-EMOCO, 19.8±15.7; DDG-EMOCO, 20.5±15.6; BG-OG, 19.6±17.1; DDG-OG, 18.9±16.6). No significant differences between BG-OG and DDG-OG, and BG-EMOCO and DDG-EMOCO, respectively, were found. Visual lesion delineation was significantly better in BG-EMOCO and DDG-EMOCO than in static reconstructions (P<0.001); no significant difference was found comparing BG and DDG (EMOCO, OG, respectively). Conclusion: DDG-based motion-compensation of CBM-PET acquisitions outperforms static reconstructions, delivering qualities comparable to hardware-based approaches. The new algorithm may be a valuable alternative for CBM-PET systems. Full Article
health and food The role of FAPI-PET/CT for patients with malignancies of the lower gastrointestinal tract - first clinical experience By jnm.snmjournals.org Published On :: 2020-02-14T14:01:21-08:00 For oncological management or radiotherapy planning, reliable staging tools are essential. Recent development of quinoline-based ligands targeting cancer-associated fibroblasts demonstrated promising preclinical and clinical results. The current study aimed to evaluate the role of fibroblast activation protein inhibitors (FAPI)-positron-emission tomography (PET)/computed tomography (CT) for primary malignancies located within the lower gastrointestinal tract (LGT) as a very first clinical analysis. Methods: 68Ga-FAPI-PET/CT was performed in a cohort of 22 patients with LGT including 15 patients with metastatic disease, 1 patient with suspected local relapse and 6 treatment-naïve patients. 68Ga-FAPI-04 and 68Ga-FAPI-46 uptake was quantified by standardized uptake values (SUV)max and (SUV)mean. After comparison with standard imaging, changes in tumor stage/ localization and (radio)oncological management were recorded. Results: The highest uptake of FAPI tracer was observed in liver metastases and anal cancer with a SUVmax of 9.1 and 13.9, respectively. Due to a low background activity in normal tissue, there was a high tumor-to-background ratio of more than 3 in most lesions. In treatment-naïve patients, TNM was changed in 50% while for patients with metastases new findings occurred in 47%. In total, FAPI-imaging caused a high, medium and low change of (radio)oncological management in 19%, 33% and 29%, respectively. For almost every patient undergoing irradiation, target volume delineation was improved by 68Ga-FAPI-PET/CT. Conclusion: The present study demonstrated that both primary and metastatic LGT were reliably detected by 68Ga-FAPI-PET/CT leading to relevant changes in TNM status and (radio)oncological management. 68Ga-FAPI-PET/CT seems to be a highly promising imaging agent for the diagnosis and management of LGT, potentially opening new applications for tumor (re-)staging. Full Article
health and food Multi-phasic 68Ga-PSMA PET/CT in detection of early recurrence in prostate cancer patients with PSA < 1 ng/ml: a prospective study of 135 cases. By jnm.snmjournals.org Published On :: 2020-02-14T14:01:21-08:00 Purpose: The main objective of this prospective study was to determine the impact of multi-phasic acquisition of 68Ga-PSMA PET/CT in the detection of recurrent prostate cancer (PCa) in the early stage of biochemical recurrence (BR) with prostate-serum-antigen (PSA) level <1ng/ml. Also, 68Ga-PSMA PET/CT positivity was correlated with clinical parameters for the assessment of predictive markers. Methods: A prospective monocentric study was conducted on 135 PCa patients with BR and PSA<1ng/ml. All patients have undergone initial prostatectomy with additional radiation therapy in 19.3% and androgen-deprivation therapy (ADT) in 7.4% of patients. Dynamic acquisition [1–8min. post-injection (p.i.)] from the prostate bed, standard whole-body (60min. p.i.) and limited bed positions of delayed studies (120-150min. p.i.), were performed. Studies were reviewed by two board-certified nuclear medicine specialists, independently. A combination of visual and semi-quantitative analyses and correlation with morphological (e.g. MRI) and/or clinical follow-up findings was used for the final interpretation of abnormal lesions as benign or malignant. 68Ga-PSMA PET/CT positivity was also correlated with primary clinical findings. Results: Incorporating the information of all phases, 116 lesions were detected in 49.6% of patients (22 local recurrences, 63 lymph nodes, and 31 distant metastases). The detection rates were 31.8%, 44.9%, and 71.4% for PSA<0.2ng/ml, 0.2≤PSA<0.5, and 0.5≤PSA<1, respectively. Additional dynamic and/or delayed phases resulted in better determination of equivocal lesions and a higher diagnostic performance in 25.9% of patients. Stand-alone dynamic and delayed images led to better interpretation of equivocal findings in the prostate bed (31.4%) and other (lymph node/bone) lesions (20%), respectively. Conclusion: 68Ga-PSMA PET/CT revealed promising results for the early detection of recurrent disease in patients with PSA level of 0.5-1.0ng/ml. However, it showed limited value in cases with PSA<0.5ng/ml. Multi-phasic 68Ga-PSMA PET/CT led to better determination of equivocal findings. Although, dynamic images may provide helpful information in assessment of the prostate bed; however, delayed acquisitions seem to have higher impact in clarifying of the equivocal findings. Full Article
health and food Performance of digital PET compared to high-resolution conventional PET in patients with cancer By jnm.snmjournals.org Published On :: 2020-02-14T14:01:21-08:00 Recently introduced PET systems using silicon photomultipliers with digital readout (dPET) have an improved timing and spatial resolution, aiming at a better image quality, over conventional PET (cPET) systems. We prospectively evaluated the performance of a dPET system in patients with cancer, as compared to high-resolution (HR) cPET imaging. Methods: After a single FDG-injection, 66 patients underwent dPET (Vereos, Philips Healthcare) and cPET (Ingenuity TF, Philips Healthcare) imaging in a randomized order. We used HR-reconstructions (2x2x2 mm3 voxels) for both scanners and determined SUVmax, SUVmean, lesion-to-background ratio (LBR), metabolic tumor volume (MTV) and lesion diameter in up to 5 FDG-positive lesions per patient. Furthermore, we counted the number of visible and measurable lesions on each PET scan. Two nuclear medicine specialists blindly determined the Tumor Node Metastasis (TNM) score from both image sets in 30 patients referred for initial staging. For all 66 patients, these specialists separately and blindly evaluated image quality (4-point scale) and determined the scan preference. Results: We included 238 lesions that were visible and measurable on both PET scans. We found 37 additional lesions on dPET in 27 patients (41%), which were unmeasurable (n = 14) or invisible (n = 23) on cPET. SUVmean, SUVmax, LBR and MTV on cPET were 5.2±3.9 (mean±SD), 6.9±5.6, 5.0±3.6 and 2991±13251 mm3, respectively. On dPET SUVmean, SUVmax and LBR increased 24%, 23% and 27%, respectively (p<0.001) while MTV decreased 13% (p<0.001) compared to cPET. Visual analysis showed TNM upstaging with dPET in 13% of the patients (4/30). dPET images also scored higher in image quality (P = 0.003) and were visually preferred in the majority of cases (65%). Conclusion: Digital PET improved the detection of small lesions, upstaged the disease and images were visually preferred as compared to high-resolution conventional PET. More studies are necessary to confirm the superior diagnostic performance of digital PET. Full Article
health and food Intraoperative 68Gallium-PSMA Cerenkov Luminescence Imaging for surgical margins in radical prostatectomy - a feasibility study By jnm.snmjournals.org Published On :: 2020-02-14T14:01:21-08:00 Objective: To assess the feasibility and accuracy of Cerenkov Luminescence Imaging (CLI) for assessment of surgical margins intraoperatively during radical prostatectomy (RPE). Methods: A single centre feasibility study included 10 patients with high-risk primary prostate cancer (PC). 68Ga-PSMA PET/CT scans were performed followed by RPE and intraoperative CLI of the excised prostate. In addition to imaging the intact prostate, in the first two patients the prostate gland was incised and imaged with CLI to visualise the primary tumour. We compared the tumour margin status on CLI to postoperative histopathology. Measured CLI intensities were determined as tumour to background ratio (TBR). Results: Tumour cells were successfully detected on the incised prostate CLI images as confirmed by histopathology. 3 of 10 men had histopathological positive surgical margins (PSMs), and 2 of 3 PSMs were accurately detected on CLI. Overall, 25 (72%) out of 35 regions of interest (ROIs) proved to visualize a tumour signal according to standard histopathology. The median tumour radiance in these areas was 11301 photons/s/cm2/sr (range 3328 - 25428 photons/s/cm2/sr) and median TBR was 4.2 (range 2.1 – 11.6). False positive signals were seen mainly at the prostate base with PC cells overlaid by benign tissue. PSMA-immunohistochemistry (PSMA-IHC) revealed strong PSMA staining of benign gland tissue, which impacts measured activities. Conclusion: This feasibility showed that 68Ga-PSMA CLI is a new intraoperative imaging technique capable of imaging the entire specimen’s surface to detect PC tissue at the resection margin. Further optimisation of the CLI protocol, or the use of lower-energetic imaging tracers such as 18F-PSMA, are required to reduce false positives. A larger study will be performed to assess diagnostic performance. Full Article
health and food Quantification of PD-L1 expression with [18F]BMS-986192 PET/CT in patients with advanced stage non-small-cell lung cancer By jnm.snmjournals.org Published On :: 2020-02-14T14:01:21-08:00 The aim of this work was to quantify the uptake of [18F]BMS-986192, a PD-L1 adnectin PET tracer, in patients with non-small-cell lung cancer (NSCLC). To this end, plasma input kinetic modeling of dynamic tumor uptake data with online arterial blood sampling was performed. In addition, the accuracy of simplified uptake metrics such as standardized uptake value (SUV) was investigated. Methods: Data from a study with [18F]BMS-986192 in patients with advanced stage NSCLC eligible for nivolumab treatment were used if a dynamic scan was available and lesions were present in the field of view of the dynamic scan. After injection of [18F]BMS-986192, a 60-minutes dynamic PET-CT scan was started, followed by a 30-min whole body PET-CT scan. Continuous arterial and discrete arterial and venous blood sampling were performed to determine a plasma input function. Tumor time activity curves were fitted by several plasma input kinetic models. Simplified uptake parameters included tumor to blood ratio as well as several SUV measures. Results: Twenty two tumors in nine patients were analyzed. The arterial plasma input single-tissue reversible compartment model with fitted blood volume fraction seems to be the most preferred model as it best fitted 11 out of 18 tumor time activity curves. The distribution volume VT ranged from 0.4 to 4.8 mL·cm-3. Similar values were obtained with an image derived input function. From the simplified measures, SUV normalized for body weight (SUVBW) at 50 and 67 minutes post injection correlated best with VT, with an R2 > 0.9. Conclusion: A single tissue reversible model can be used for the quantification of tumor uptake of the PD-L1 PET tracer [18F]BMS-986192. SUVBW at 60 minutes post injection, normalized for body weight, is an accurate simplified parameter for uptake assessment of baseline studies. In order to assess its predictive value for response evaluation during PD-(L)1 immune checkpoint inhibition further validation of SUV against VT based on an image derived input function is recommended. Full Article
health and food Interim PET assessment of advanced Hodgkin Lymphoma: is it sufficient? By jnm.snmjournals.org Published On :: 2020-02-14T14:01:21-08:00 Full Article
health and food Clinical Translation of a 68Ga-labeled Integrin {alpha}v{beta}6-targeting Cyclic Radiotracer for PET Imaging of Pancreatic Cancer By jnm.snmjournals.org Published On :: 2020-02-21T14:46:23-08:00 The overexpression of integrin αvβ6 in pancreatic cancer makes it a promising target for noninvasive positron emission tomography (PET) imaging. However, currently, most integrin αvβ6-targeting radiotracers are based on linear peptides, which are quickly degraded in the serum by proteinases. Herein, we aimed to develop and assess a 68Ga-labeled integrin αvβ6-targeting cyclic peptide (68Ga-cycratide) for PET imaging of pancreatic cancer. Methods: 68Ga-cycratide was prepared, and its PET imaging profile was compared with that of the linear peptide (68Ga-linear-pep) in an integrin αvβ6-positive BxPC-3 human pancreatic cancer mouse model. Five healthy volunteers (two women and three men) underwent whole-body PET/CT imaging after injection of 68Ga-cycratide, and biodistribution and dosimetry calculations were determined. PET/CT imaging of two patients was performed to investigate the potential role of 68Ga-cycratide in pancreatic cancer diagnosis and treatment monitoring. Results: 68Ga-cycratide exhibited significantly higher tumor uptake than did 68Ga-linear-pep in BxPC-3 tumor-bearing mice, owing—at least in part—to markedly improved in vivo stability. 68Ga-cycratide could sensitively detect the pancreatic cancer lesions in an orthotopic mouse model and was well tolerated in all healthy volunteers. Preliminary PET/CT imaging in patients with pancreatic cancer demonstrated that 68Ga-cycratide was comparable to 18F-fludeoxyglucose for diagnostic imaging and post-surgery tumor relapse monitoring. Conclusion: 68Ga-cycratide is an integrin αvβ6-specific PET radiotracer with favorable pharmacokinetics and dosimetry profile. 68Ga-cycratide is expected to provide an effective noninvasive PET strategy for pancreatic cancer lesion detection and therapy response monitoring. Full Article
health and food Diagnosis of Hyper-progressive Disease in Patients Treated with Checkpoint Inhibitors using 18F-FDG PET/CT By jnm.snmjournals.org Published On :: 2020-02-21T14:46:23-08:00 Full Article
health and food Development and evaluation of interleukin-2 derived radiotracers for PET imaging of T-cells in mice By jnm.snmjournals.org Published On :: 2020-02-28T13:52:17-08:00 Recently, N-(4-18F-fluorobenzoyl)-interleukin-2 (18F-FB-IL2) was introduced as PET tracer for T-cell imaging. However, production is complex and time-consuming. Therefore, we developed two radiolabeled interleukin-2 (IL-2) variants, namely aluminum 18F-fluoride-(restrained complexing agent)-IL-2 (18F-AlF-RESCA-IL2) and 68Ga-gallium-(1,4,7-triazacyclononane-4,7-diacetic acid-1-glutaric acid)-IL-2 (68Ga-Ga-NODAGA-IL2) and compared their in-vitro and in-vivo characteristics with 18F-FB-IL2. Methods: Radiolabeling of 18F-AlF-RESCA-IL2 and 68Ga-Ga-NODAGA-IL2 was optimized and stability was evaluated in human serum. Receptor binding was studied with activated human peripheral blood mononuclear cells (hPBMCs). Ex-vivo tracer biodistribution in immunocompetent BALB/cOlaHsd (BALB/c) mice was performed at 15, 60 and 90 min after tracer injection. In-vivo binding characteristics were studied in severe combined immune-deficient (SCID) mice inoculated with activated hPBMCs in Matrigel. Tracer was injected 15 min after hPBMCs inoculation and a 60-min dynamic PET scan was acquired, followed by ex-vivo biodistribution studies. Specific uptake was determined by co-injection of tracer with unlabeled IL2 and by evaluating uptake in a control group inoculated with Matrigel only. Results: 68Ga-Ga-NODAGA-IL2 and 18F-AlF-RESCA-IL2 were produced with radiochemical purity >95% and radiochemical yield of 13.1±4.7% and 2.4±1.6% within 60 and 90 min, respectively. Both tracers were stable in serum, with >90% being intact tracer after 1h. In-vitro, both tracers displayed preferential binding to activated hPBMCs. Ex-vivo biodistribution studies in BALB/c mice showed higher uptake of 18F-AlF-RESCA-IL2 than 18F-FB-IL2 in liver, kidney, spleen, bone and bone marrow. 68Ga-Ga-NODAGA-IL2 uptake in liver and kidney was higher than 18F-FB-IL2 uptake. In-vivo, all tracers revealed uptake in activated hPBMCs in SCID mice. Low uptake was seen after a blocking dose of IL2 or in the Matrigel control group. In addition, 18F-AlF-RESCA-IL2 yielded highest contrast PET images of target lymph nodes. Conclusion: Production of 18F-AlF-RESCA-IL2 and 68Ga-Ga-NODAGA-IL2 is simpler and faster than 18F-FB-IL2. Both tracers showed good in-vitro and in-vivo characteristics with high uptake in lymphoid tissue and hPBMC xenografts. Full Article
health and food High Resolution Depth-Encoding PET Detector Module with Prismatoid Light Guide Array By jnm.snmjournals.org Published On :: 2020-02-28T13:52:17-08:00 Depth-encoding detectors with single-ended readout provide a practical, cost-effective approach for constructing high resolution and high sensitivity PET scanners. However, the current iteration of such detectors utilizes a uniform glass light guide to achieve depth-encoding, resulting in non-uniform performance throughout the detector array due to suboptimal intercrystal light sharing. We introduce Prism-PET, a single-ended readout PET detector module with a segmented light guide composed of an array of prismatoids that introduces enhanced, deterministic light sharing. Methods: High resolution PET detector modules were fabricated with single-ended readout of polished multicrystal lutetium yttrium orthosilicate (LYSO) scintillator arrays directly coupled 4-to-1 and 9-to-1 to arrays of 3.2 x 3.2 mm2 silicon photomultiplier pixels. Each scintillator array was coupled at the non-readout side to a light guide (one 4-to-1 module with a uniform glass light guide, one 4-to-1 Prism-PET module and one 9-to-1 Prism-PET module) to introduce intercrystal light sharing, which closely mimics the behavior of dual-ended readout with the additional benefit of improved crystal identification. Flood histogram data was acquired using a 3 MBq Na-22 source to characterize crystal identification and energy resolution. Lead collimation was used to acquire data at specific depths to determine depth-of-interaction (DOI) resolution. Results: The flood histogram measurements showed excellent and uniform crystal separation throughout the Prism-PET modules while the uniform glass light guide module had performance degradation at the edges and corners. A DOI resolution of 5.0 mm full width at half maximum (FWHM) and energy resolution of 13% were obtained in the uniform glass light guide module. By comparison, the 4-to-1 coupled Prism-PET module achieved 2.5 mm FWHM DOI resolution and 9% energy resolution. Conclusion: PET scanners based on our Prism-PET modules with segmented prismatoid light guide arrays can achieve high and uniform spatial resolution (9-to-1 coupling with ~ 1 mm crystals), high sensitivity, good energy and timing resolutions (using polished crystals and after applying DOI-correction), and compact size (depth-encoding eliminates parallax error and permits smaller ring-diameter). Full Article
health and food Digital Solid-State SPECT/CT Quantitation of Absolute 177Lu-Radiotracer Concentration: In Vivo/In Vitro Validation By jnm.snmjournals.org Published On :: 2020-02-28T13:52:17-08:00 The accuracy of lutetium-177 (177Lu) radiotracer concentration measurements using quantitative clinical software was determined by comparing in vivo results for a digital solid-state cadmium-zinc-telluride SPECT/CT (single photon emission computed tomography / x-ray computed tomography) system to in vitro sampling. First, image acquisition parameters were assessed for an International Electrotechnical Commission (IEC) body phantom emulating clinical count rates loaded with a "lung" insert and 6 hot spheres with a 12:1 target-to-background ratio of 177Lu solution. Then, the data of 28 whole-body SPECT/CT scans of 7 patients who underwent 177Lu prostate membrane antigen (177Lu-PSMA) radioligand therapy was retrospectively analyzed. Three users analyzed SPECT/CT images for in vivo urinary bladder radiotracer uptake using quantitative software (Q.Metrix, GE Healthcare). In vitro radiopharmaceutical concentrations were calculated using urine sampling obtained immediately after each scan, scaled to standardized uptake values (SUVs). Any in vivo/in vitro identity relations were determined by linear regression (ideally slope=1, intercept=0), within a 95 % confidence interval (CI). Phantom results demonstrated lower quantitative error for acquisitions using the 113 keV 177Lu energy peak rather than including the 208 keV peak, given that only low-energy collimation was available in this camera configuration. In the clinical study, 24 in vivo/in vitro pairs were eligible for further analysis, having rejected 4 as outliers (via Cook’s distance calculations). All linear regressions (R2 ≥ 0.92, P<0.0001) provided identity in vivo/in vitro relations (95 % CI), with SUV averages from all users giving a slope of 1.03±0.09, an intercept of –0.25±0.64 g/mL, and an average residual difference of 20.4 %. Acquiring with the lower energy 177Lu energy peak, solid-state SPECT/CT imaging provides an accuracy to within ~20 % for in vivo urinary bladder radiotracer concentrations. This non-invasive in vivo quantitation method can potentially improve diagnosis, improve patient management and treatment response assessment, and provide data essential to 177Lu dosimetry. Full Article
health and food 64Cu-DOTATATE PET/CT and prediction of overall and progression-free survival in patients with neuroendocrine neoplasms By jnm.snmjournals.org Published On :: 2020-02-28T13:52:17-08:00 Overexpression of somatostatin receptors in patients with neuroendocrine neoplasms (NEN) is utilized for both diagnosis and treatment. Receptor density may reflect tumor differentiation and thus be associated with prognosis. Non-invasive visualization and quantification of somatostatin receptor density is possible by somatostatin receptor imaging (SRI) using positron emission tomography (PET). Recently, we introduced 64Cu-DOTATATE for SRI and we hypothesized that uptake of this tracer could be associated with overall (OS) and progression-free survival (PFS). Methods: We evaluated patients with NEN that had a 64Cu-DOTATATE PET/CT SRI performed in two prospective studies. Tracer uptake was determined as the maximal standardized uptake value (SUVmax) for each patient. Kaplan-Meier analysis with log-rank was used to determine the predictive value of 64Cu-DOTATATE SUVmax for OS and PFS. Specificity, sensitivity and accuracy was calculated for prediction of outcome at 24 months after 64Cu-DOTATATE PET/CT. Results: A total of 128 patients with NEN were included and followed for a median of 73 (1-112) months. During follow-up, 112 experienced disease progression and 69 patients died. The optimal cutoff for 64Cu-DOTATATE SUVmax was 43.3 for prediction of PFS with a hazard ratio of 0.56 (95% CI: 0.38-0.84) for patients with SUVmax > 43.3. However, no significant cutoff was found for prediction of OS. In multiple Cox regression adjusted for age, sex, primary tumor site and tumor grade, the SUVmax cutoff hazard ratio was 0.50 (0.32-0.77) for PFS. The accuracy was moderate for predicting PFS (57%) at 24 months after 64Cu-DOTATATE PET/CT. Conclusion: In this first study to report the association of 64Cu-DOTATATE PET/CT and outcome in patients with NEN, tumor somatostatin receptor density visualized with 64Cu-DOTATATE PET/CT was prognostic for PFS but not OS. However, the accuracy of prediction of PFS at 24 months after 64Cu-DOTATATE PET/CT SRI was moderate limiting the value on an individual patient basis. Full Article
health and food Early prostate-specific antigen changes and clinical outcome following 177Lu-PSMA radionuclide treatment in patients with metastatic castration-resistant prostate cancer By jnm.snmjournals.org Published On :: 2020-02-28T13:52:17-08:00 Background: Prostate-specific antigen (PSA) is widely used to monitor treatment response in patients with metastatic castration-resistant prostate cancer (mCRPC). However, PSA measurements are considered only after 12 wk of treatment. We aimed to evaluate the prognostic value of early PSA changes following 177Lu-labelled prostate specific membrane antigen (LuPSMA) radionuclide treatment in mCRPC patients. Methods: Men who were treated under a compassionate access program with LuPSMA at our institution and had available PSA values at baseline, at 6 wk after treatment initiation were included in this retrospective analysis. Patients were assigned to three groups based on PSA changes: 1) response: ≥30% decline, 2) progression: ≥25% increase and 3) stable: <30% decline and <25% increase. The co-primary endpoints were overall survival and imaging-based progression-free survival. The secondary end points were PSA changes at 12 wk and PSA flare-up. Results: We identified 124 eligible patients with PSA values at 6 wk. A ≥30% decline in PSA at 6 wk was associated with longer overall survival (median 16.7 mo; 95%CI 14.4–19.0) compared with patients with stable PSA (median: 11.8 mo; 95%CI 8.6–15.1; P = 0.007) and progression (median: 6.5 mo; 95%CI 5.2–7.8; p<0.001). Patients with ≥30% decline in PSA at 6 wk also had a reduced risk of imaging-based progression compared with patients with stable PSA (HR: 0.60; 95%CI 0.38–0.94; P = 0.02), while patients with PSA progression had a higher risk of imaging-based progression compared with those showing stable PSA (HR: 3.18; 95%CI 1.95–5.21; p<0.001). The percentage changes of PSA at 6 wk and 12 wk were highly associated (r=0.90; p<0.001). 29 of 31 (94%) patients who experienced early PSA progression at 6 wk achieved biochemical progression at 12 wk. Overall, only 1 of 36 (3%) patients with PSA progression at 6 wk achieved any PSA decline at 12 wk (1% of the entire cohort). Limitations of the study included its retrospective nature and the single center experience. Conclusion: PSA changes at 6 wk after LuPSMA initiation are an early indicator of long-term clinical outcome. Patients progressing by PSA after 6 wk of treatment could benefit from a very early treatment switch decision. PSA flare-up during LuPSMA treatment is very uncommon. Prospective studies are now warranted to validate our findings and potentially inform clinicians earlier on the effectiveness of LuPSMA. Full Article
health and food Kinetic modeling and test-retest reproducibility of 11C-EKAP and 11C-FEKAP, novel agonist radiotracers for PET imaging of the kappa opioid receptor in humans By jnm.snmjournals.org Published On :: 2020-03-13T14:12:30-07:00 The kappa opioid receptor (KOR) is implicated in various neuropsychiatric disorders. We previously evaluated an agonist tracer, 11C-GR103545, for PET imaging of KOR in humans. Although 11C-GR103545 showed high brain uptake, good binding specificity, and selectivity to KOR, it displayed slow kinetics and relatively large test-retest variability (TRV) of distribution volume (VT) estimates (15%). Therefore we set out to develop two novel KOR agonist radiotracers, 11C-EKAP and 11C-FEKAP, and in nonhuman primates, both tracers exhibited faster kinetics and comparable binding parameters to 11C-GR103545. The aim of this study was to assess their kinetic and binding properties in humans. Methods: Six healthy subjects underwent 120-min test-retest PET scans with both 11C-EKAP and 11C-FEKAP. Metabolite-corrected arterial input functions were measured. Regional time-activity curves (TACs) were generated for 14 regions of interest. One- and two-tissue compartment models (1TC, 2TC) and the multilinear analysis-1 (MA1) method were applied to the regional TACs to calculate VT. Time-stability of VT values and test-retest reproducibility were evaluated. Levels of specific binding, as measured by the non-displaceable binding potential (BPND) for the three tracers (11C-EKAP, 11C-FEKAP and 11C-GR103545), were compared using a graphical method. Results: For both tracers, regional TACs were fitted well with the 2TC model and MA1 method (t*=20min), but not with the 1TC model. Given unreliably estimated parameters in several fits with the 2TC model and a good match between VT values from MA1 and 2TC, MA1 was chosen as the appropriate model for both tracers. Mean MA1 VT values were highest for 11C-GR103545, followed by 11C-EKAP, then 11C-FEKAP. Minimum scan time for stable VT measurement was 90 and 110min for 11C-EKAP and 11C-FEKAP, respectively, compared with 140min for 11C-GR103545. The mean absolute TRV in MA1 VT estimates was 7% and 18% for 11C-EKAP and 11C-FEKAP, respectively. BPND levels were similar for 11C-FEKAP and 11C-GR103545, but ~25% lower for 11C-EKAP. Conclusion: The two novel KOR agonist tracers showed faster tissue kinetics than 11C-GR103545. Even with slightly lower BPND, 11C-EKAP is judged to be a better tracer for imaging and quantification of KOR in humans, based on the shorter minimum scan time and excellent test-retest. Full Article
health and food First-in-Human Trial of Dasatinib-Derivative Tracer for Tumor Kinase-Targeted Positron Emission Tomography By jnm.snmjournals.org Published On :: 2020-03-13T14:12:30-07:00 We developed a first-of-kind dasatinib-derivative imaging agent, 18F-SKI-249380 (18F-SKI), and validated its use for noninvasive in vivo tyrosine kinase-targeted tumor detection in preclinical models. In this study, we assess the feasibility of using 18F-SKI for PET imaging in patients with malignancies. Methods: Five patients with a prior diagnosis of breast cancer, renal cell cancer, or leukemia underwent whole-body PET/CT imaging 90 min post-injection of 18F-SKI (mean: 241.24 ± 116.36 MBq) as part of a prospective study. In addition, patients underwent either a 30-min dynamic scan of the upper abdomen including, at least partly, cardiac left ventricle, liver, spleen, and kidney (n = 2) or three 10-min whole-body PET/CT scans (n = 3) immediately post-injection and blood-based radioactivity measurements to determine the time course of tracer distribution and facilitate radiation dose estimates. A subset of three patients had a delayed whole-body PET/CT scan at 180 min. Biodistribution, dosimetry, and tumor uptake were quantified. Absorbed doses were calculated using OLINDA/EXM 1.0. Results: No adverse events occurred after injection of 18F-SKI. A total of 27 tumor lesions were analyzed with median SUVpeak 1.4 (range, 0.7–2.3) and tumor-to-blood ratios of 1.6 (range, 0.8–2.5) at 90 min post-injection. Intratumoral drug concentrations calculated for four reference lesions ranged from 0.03–0.07 nM. In all reference lesions, constant tracer accumulation was observed between 30–90 min post-injection. Blood radio-assay indicated that radiotracer clearance from blood and plasma was initially rapid (blood half-time 1.31 ± 0.81 min, plasma 1.07 ± 0.66 min; n = 4), followed variably by either a prolonged terminal phase (blood half-time 285 ± 148.49 min, plasma 240 ± 84.85 min; n = 2) or a small rise to plateau (n = 2). Like dasatinib, 18F-SKI underwent extensive metabolism post-administration, as evidenced by metabolite analysis. Radioactivity was predominantly cleared via the hepatobiliary route. The highest absorbed dose estimates (mGy/MBq) in normal tissues were to the right colon (0.167 ± 0.04) and small intestine (0.153 ± 0.03). The effective dose was 0.0258 (SD 0.0034) mSv/MBq. Conclusion: 18F-SKI demonstrated significant tumor uptake, distinct image contrast despite low injected doses, and rapid clearance from blood. Full Article
health and food Biokinetics of Radiolabeled Monoclonal Antibody BC8: Differences in Biodistribution and Dosimetry among Hematologic Malignancies. By jnm.snmjournals.org Published On :: 2020-03-13T14:12:30-07:00 We reviewed 111In-DOTA-anti-CD45 antibody (BC8) imaging and bone marrow biopsy measurements to ascertain biodistribution and biokinetics of the radiolabeled antibody and to investigate differences based on type of hematologic malignancy. Methods: Serial whole-body scintigraphic images (4 time-points) were obtained after infusion of the 111In-DOTA-BC8 (176-406 MBq) in 52 adult patients with hematologic malignancies (lymphoma, multiple myeloma, acute myeloid leukemia and myelodysplastic syndrome). Counts were obtained for the regions of interest for spleen, liver, kidneys, testicles (in males), and two marrow sites (acetabulum and sacrum) and correction for attenuation and background was made. Bone marrow biopsies were obtained 14-24 hours post-infusion and percent of administered activity was determined. Radiation absorbed doses were calculated. Results: Initial uptake in liver averaged 32% ± 8.4% (S.D.) of administered activity (52 patients), which cleared monoexponentially with biological half-time of 293 ± 157 hours (33 patients) or did not clear (19 patients). Initial uptake in spleen averaged 22% ± 12% and cleared with a biological half-time 271 ± 185 hours (36 patients) or longer (6 patients). Initial uptake in kidney averaged 2.4% ± 2.0% and cleared with a biological half-time of 243 ± 144 hours (27 patients) or longer (9 patients). Initial uptake in red marrow averaged 23% ± 11% and cleared with half-times of 215 ± 107 hours (43 patients) or longer (5 patients). Whole-body retention half-times averaged 198 ± 75 hours. Splenic uptake was higher in the AML/MDS group when compared to the lymphoma group (p ≤ 0.05) and to the multiple myeloma group (p ≤ 0.10). Liver represented the dose-limiting organ. For liver uptake, no significant differences were observed between the three malignancy groups. Average calculated radiation absorbed doses per unit administered activity for a therapy infusions of 90Y-DOTA-BC8 were for red marrow: 470 ± 260 cGy/MBq, liver 1100 ± 330 cGy/MBq, spleen 4120 ± 1950 cGy/MBq, total body 7520 ± 20 cGy/MBq, osteogenic cells 290 ± 200 cGy/MBq, and kidneys 240 ± 200 cGy/MBqR. Conclusion: 111In-DOTA-BC8 had long retention time in liver, spleen, kidneys, and red marrow, and the highest absorbed doses were calculated for spleen and liver. Few differences were observed by malignancy type. The exception was greater splenic uptake among leukemia/MDS group when compared to lymphoma and multiple myeloma groups. Full Article
health and food Initial Clinical Results of a Novel Immuno-PET Theranostic Probe in HER2-negative Breast Cancer By jnm.snmjournals.org Published On :: 2020-03-13T14:12:30-07:00 Purpose: This prospective study evaluated the imaging performance of a novel immunological pretargeting positron-emission tomorgraphy (immuno-PET) method in patients with HER2-negative, carcinoembryonic antigen (CEA)-positive, metastatic breast cancer (BC), compared to computed tomography (CT), bone magnetic resonance imaging (MRI), and 18Fluorodeoxyglucose PET (FDG-PET). Patients and Methods: Twenty-three patients underwent whole-body immuno-PET after injection of 150 MBq 68Ga-IMP288, a histamine-succinyl-glycine peptide given following initial targeting of a trivalent anti-CEA, bispecific, anti-peptide antibody. The gold standards were histology and imaging follow-up. Tumor standard uptake values (SUVmax and SUVmean) were measured, and tumor burden analyzed using Total Tumor Volume (TTV) and Total Lesion Activity (TLA). Results: Total lesion sensitivity of immuno-PET and FDG-PET was 94.7% (1116/1178) and 89.6% (1056/1178), respectively. Immuno-PET had a somewhat higher sensitivity than CT and FDG-PET in lymph nodes (92.4% vs 69.7% and 89.4%, respectively) and liver metastases (97.3% vs 92.1% and 94.8%, respectively), whereas sensitivity was lower for lung metastases (48.3% vs 100% and 75.9%, respectively). Immuno-PET showed higher sensitivity than MRI and FDG-PET for bone lesions (95.8% vs 90.7% and 89.3%, respectively). In contrast to FDG-PET, immuno-PET disclosed brain metastases. Despite equivalent tumor SUVmax, SUVmean, and TTV, TLA was significantly higher with immuno-PET compared to FDG PET (P = 0.009). Conclusion: Immuno-PET using anti-CEA/anti-IMP288 bispecific antibody, followed by 68Ga-IMP288, is a potentially sensitive theranostic imaging method for HER2-negative, CEA-positive, metastatic BC patients, and warrants further research. Full Article
health and food Design and development of 99mTc labeled FAPI-tracers for SPECT-imaging and 188Re therapy. By jnm.snmjournals.org Published On :: 2020-03-13T14:12:30-07:00 The majority of epithelial tumors recruits fibroblasts and other non-malignant cells and activates them into cancer-associated fibroblasts. This often leads to overexpression of the membrane serine protease fibroblast-activating protein (FAP). It has already been shown that DOTA-bearing FAP inhibitors (FAPIs) generate high contrast images with PET/CT scans. Since SPECT is a lower cost and more widely available alternative to PET, 99mTc-labeled FAPIs represent attractive tracers for imaging applicable in a larger number of patients. Furthermore, the chemically homologous nuclide 188Re is available from generators, which allows FAP-targeted endoradiotherapy. Methods: For the preparation of 99mTc tricarbonyl complexes, a chelator was selected whose carboxylic acids can easily be converted into various derivatives in the finished product. This enabled a platform strategy based on the original tracer. The obtained 99mTc complexes were investigated in vitro by binding and competition experiments on FAP-transfected HT-1080 (HT-1080-FAP) and/or on mouse FAP expressing (HEK-muFAP) and CD26-expressing (HEKCD26) HEK cells and characterized by planar scintigraphy and organ distribution studies in tumor-bearing mice. Furthermore, a first-in-man application was done in two patients with ovarian and pancreatic cancer, respectively. Results: 99mTc-FAPI-19 showed specific binding to recombinant FAP-expressing cells with high affinity. Unfortunately, liver accumulation, biliary excretion and no tumor uptake were observed in the planar scintigraphy of a HT-1080-FAP xenotranplanted mouse. To improve the pharmacokinetic properties hydrophilic amino acids were attached to the chelator moiety of the compound. The resulting 99mTc-labeled FAPI tracers revealed excellent binding properties (up to 45 % binding; above 95 % internalization), high affinity (IC50 = 6.4 nM to 12.7 nM), and significant tumor uptake (up to 5.4 %ID/g) in biodistribution studies. The lead candidate 99mTc-FAPI-34 was applied for diagnostic scintigraphy and SPECT of patients with metastasized ovarian and pancreatic cancer for follow-up to therapy with 90Y-FAPI-46. 99mTc-FAPI-34 accumulated in the tumor lesions also shown in PET/CT imaging using 68Ga-FAPI-46. Conclusion: 99mTc-FAPI-34 represents a powerful tracer for diagnostic scintigraphy, especially in cases where PET imaging is not available. Additionally, the chelator used in this compound allows labeling with the therapeutic nuclide 188Re which is planned for the near future. Full Article
health and food OpenDose: open access resources for nuclear medicine dosimetry By jnm.snmjournals.org Published On :: 2020-03-13T14:12:30-07:00 Background: Radiopharmaceutical dosimetry depends on the localization in space and time of radioactive sources and requires the estimation of the amount of energy emitted by the sources deposited within targets. In particular, when computing resources are not accessible, this task can be carried out using precomputed tables of Specific Absorbed Fractions (SAFs) or S values based on dosimetric models. The OpenDose collaboration aims to generate and make freely available a range of dosimetric data and tools. Methods: OpenDose brings together resources and expertise from 18 international teams to produce and compare traceable dosimetric data using 6 of the most popular Monte Carlo codes in radiation transport (EGSnrc/EGS++, FLUKA, GATE, Geant4, MCNP/MCNPX and PENELOPE). SAFs are uploaded, together with their associated statistical uncertainties, in a relational database. S values are then calculated from mono-energetic SAFs, based on the radioisotope decay data presented in the International Commission on Radiological Protection (ICRP) publication 107. Results: The OpenDose collaboration produced SAFs for all source regions and targets combinations of the two ICRP 110 adult reference models. SAFs computed from the different Monte Carlo codes were in good agreement at all energies, with standard deviations below individual statistical uncertainties. Calculated S values were in good agreement with OLINDA 2 (commercial) and IDAC 2.1 (free) software. A dedicated website (www.opendose.org) has been developed to provide easy and open access to all data. Conclusion: The OpenDose website allows the display and download of SAFs and the corresponding S values for 1252 radionuclides. The OpenDose collaboration, open to new research teams, will extend data production to other dosimetric models and implement new free features, such as online dosimetric tools and patient-specific absorbed dose calculation software, together with educational resources. Full Article
health and food Prognostic Value of 18F-FDG PET/CT in a Large Cohort of 495 Patients with Advanced Metastatic Neuroendocrine Neoplasms (NEN) Treated with Peptide Receptor Radionuclide Therapy (PRRT) By jnm.snmjournals.org Published On :: 2020-03-13T14:12:30-07:00 The objective of this retrospective study was to determine the role of 18F-FDG PET/CT in a large cohort of 495 patients with metastatic neuroendocrine neoplasms (NENs) who were treated with peptide receptor radionuclide therapy (PRRT) with a long-term follow-up. Methods: The 495 patients were treated with 177Lu- and/or 90Y- DOTATOC/DOTATATE PRRT between 2/2002 and 7/2018. All subjects received both 68Ga-DOTATOC/TATE/NOC and 18F-FDG PET/CT prior to treatment and were followed 3-189 months. Kaplan-Meier analysis, log-rank test (Mantel-Cox), and Cox regression analysis were performed for overall survival (OS) and progression-free survival (PFS). Results: 199 patients (40.2%) presented with pancreatic NEN, 49 with CUP (cancer of unknown primary), 139 with midgut NEN, whereas the primary tumor was present in the rectum in 20, in the lung in 38, in the stomach in 8 and other locations in 42 patients. FDG-PET/CT was positive in 382 (77.2%) patients and 113 (22.8%) were FDG-negative before PRRT, while 100% were 68Ga-DOTATOC/TATE/NOC positive. For all patients, the median PFS and OS, defined from start of PRRT, were 19.6 mo and 58.7 mo, respectively. Positive FDG predicted shorter PFS (18.5 mo vs 24.1 mo; P = 0.0015) and OS (53.2 mo vs 83.1 mo; P < 0.001) than negative FDG. Amongst the pancreatic NEN, the median OS was 52.8 mo in FDG positive and 114.3 mo in FDG negative subjects (P = 0.0006). For all patients with positive 18F-FDG uptake, and a ratio of the highest SUVmax on 68Ga-SSTR PET to the most 18F-FDG-avid tumor lesions >2, the median OS was 53.0 mo, compared to 43.4 mo in those patients with a ratio <2 (P = 0.030). For patients with no 18F-FDG uptake (complete "mismatch" imaging pattern), the median OS was 108.3 mo vs 76.9 mo for SUVmax >15.0 and ≤15.0 on 68Ga-SSTR PET/CT, respectively. Conclusion: The presence of positive lesions on 18F-FDG PET is an independent prognostic factor in patients with NEN treated with PRRT. Metabolic imaging with 18F-FDG PET/CT compliments the molecular imaging aspect of 68Ga-SSTR PET/CT for the prognosis of survival after PRRT. High SSTR expression combined with negative 18F-FDG PET/CT imaging is associated with the most favorable long-term prognosis. Full Article
health and food 68Ga-PSMA guided bone biopsies for molecular diagnostics in metastatic prostate cancer patients By jnm.snmjournals.org Published On :: 2020-03-13T14:12:30-07:00 For individual treatment decisions in patients with metastatic prostate cancer (mPC), molecular diagnostics are increasingly used. Bone metastases are frequently the only source for obtaining metastatic tumor tissue. However, the success rate of computed tomography (CT)-guided bone biopsies for molecular analyses in mPC patients is only ~40%. Positron emission tomography (PET) using Gallium-68 prostate specific membrane antigen (68Ga-PSMA) is a promising tool to improve the harvest rate of bone biopsies for molecular analyses. Aim of this study was to determine the success rate of 68Ga-PSMA guided bone biopsies for molecular diagnostics in mPC patients. Methods: Within a prospective multicenter whole-genome sequencing trial (NCT01855477), 69 mPC patients underwent 68Ga-PSMA PET/CT prior to bone biopsy. Primary endpoint was success rate (tumor percentage ≥30%) of 68Ga-PSMA guided bone biopsies. At biopsy sites, 68Ga-PSMA uptake was quantified using rigid body image registration of 68Ga-PSMA PET/CT and interventional CT. Actionable somatic alterations were identified. Results: Success rate of 68Ga-PSMA guided biopsies for molecular analyses was 70%. At biopsy sites categorized as positive, inconclusive, or negative for 68Ga-PSMA uptake, 70%, 64%, and 36% of biopsies were tumor positive (≥30%), respectively (P = 0.0610). In tumor positive biopsies, 68Ga-PSMA uptake was significantly higher (P = 0.008), whereas radiodensity was significantly lower (P = 0.006). With an area under the curve of 0.84 and 0.70, both 68Ga-PSMA uptake (maximum standardized uptake value) and radiodensity (mean Hounsfield Units) were strong predictors for a positive biopsy. Actionable somatic alterations were detected in 73% of the sequenced biopsies. Conclusion: In patients with mPC, 68Ga-PSMA PET/CT improves the success rate of CT-guided bone biopsies for molecular analyses, thereby identifying actionable somatic alterations in more patients. Therefore, 68Ga-PSMA PET/CT may be considered for guidance of bone biopsies in both clinical practice and clinical trials. Full Article
health and food Neuroendocrine Differentiation and Response toPSMA-Targeted Radioligand Therapy in Advanced Metastatic Castration-Resistant Prostate Cancer: a Single-Center Retrospective Study By jnm.snmjournals.org Published On :: 2020-03-13T14:12:30-07:00 Introduction: Neuroendocrine differentiation is associated with treatment failure and poor outcome in metastatic castration-resistant prostate cancer (mCRPC). We investigated the effect of circulating neuroendocrine biomarkers on the efficacy of PSMA-targeted radioligand therapy (RLT). Methods: Neuroendocrine biomarker profiles (progastrin-releasing peptide, neuron-specific enolase, and chromogranin-A) were analyzed in 50 patients commencing 177Lu-PSMA-617 RLT. The primary endpoint was PSA response in relation to baseline neuroendocrine marker profiles. Additional endpoints included progression-free survival. Tumor uptake on post-therapeutic scans, a known predictive marker for response, was used as control-variable. Results: Neuroendocrine biomarker profiles were abnormal in the majority of patients. Neuroendocrine biomarker levels did not predict treatment failure or early progression (P ≥ 0.13). By contrast, intense PSMA-ligand uptake in metastases predicted both treatment response (P = 0.0030) and reduced risk of early progression (P = 0.0111). Conclusion: Neuroendocrine marker profiles do not predict adverse outcome of RLT. By contrast, high ligand uptake was confirmed to be crucial for achieving tumor-response. Full Article
health and food Defining hyper-progressive disease using tumor growth rate: what are limitations and shortcuts? By jnm.snmjournals.org Published On :: 2020-03-13T14:12:30-07:00 Full Article
health and food The optimal imaging window for dysplastic colorectal polyp detection using c-Met targeted fluorescence molecular endoscopy By jnm.snmjournals.org Published On :: 2020-03-20T13:59:23-07:00 Rationale: Fluorescence molecular endoscopy (FME) is an emerging technique that has the potential to improve the 22% colorectal polyp detection miss-rate. We determined the optimal dose-to-imaging interval and safety of FME using EMI-137, a c-Met targeted fluorescent peptide, in a population at high-risk for colorectal cancer. Methods: We performed in vivo FME and quantification of fluorescence by multi-diameter single-fiber reflectance, single-fiber fluorescence spectroscopy in 15 patients with a dysplastic colorectal adenoma. EMI-137 was intravenously administered (0.13mg/kg) at a one-, two- or three-hour dose-to-imaging interval (N = 3 patients per cohort). Two cohorts were expanded to six patients based on target-to-background ratios (TBR). Fluorescence was correlated to histopathology and c-Met expression. EMI-137 binding specificity was assessed by fluorescence microscopy and in vitro experiments. Results: FME using EMI-137 appeared to be safe and well tolerated. All dose-to-imaging intervals showed significantly increased fluorescence in the colorectal lesions compared to surrounding tissue, with a TBR of 1.53, 1.66 and 1.74 respectively (mean intrinsic fluorescence (Q·μfa,x) = 0.035 vs. 0.023mm-1, P<0.0003; 0.034 vs. 0.021mm-1, P<0.0001; 0.033 vs. 0.019mm-1, P<0.0001). Fluorescence correlated to histopathology on a macroscopic and microscopic level, with significant c-Met overexpression in dysplastic mucosa. In vitro, a dose-dependent specific binding was confirmed. Conclusion: FME using EMI-137 appeared to be safe and feasible within a one-to-three hour dose-to-imaging interval. No clinically significant differences were observed between the cohorts, although a one-hour dose-to-imaging interval was preferred from a clinical perspective. Future studies will investigate EMI-137 for improved colorectal polyp detection during screening colonoscopies. Full Article
health and food 11C-PABA as a Novel PET Radiotracer for Functional Renal Imaging: Preclinical and First-in-Human Studies By jnm.snmjournals.org Published On :: 2020-03-20T13:59:23-07:00 para-Aminobenzoic acid (PABA) has been previously used as an exogenous marker to verify completion of 24-hour urine sampling. Therefore, we hypothesized that radiolabeled PABA with 11C could allow high-quality dynamic PET of the kidneys while reducing the radiation exposure due to its short biological and physical half-lives. We evaluated if 11C-PABA could visualize renal anatomy and quantify function in healthy rats, rabbits, and first-in-human studies in healthy volunteers. Methods: Healthy rats and rabbits were injected with 11C-PABA intravenously. Subsequently, a dynamic PET was performed, followed by post-mortem tissue biodistribution studies. 11C-PABA PET was directly compared with the current standard, 99mTc-MAG3 in rats. Three healthy human subjects also underwent dynamic PET after intravenous injection of 11C-PABA. Results: In healthy rats and rabbits, dynamic PET demonstrated a rapid accumulation of 11C-PABA in the renal cortex, followed by rapid excretion through the pelvicalyceal system. In humans, 11C-PABA PET was safe and well tolerated. There were no adverse or clinically detectable pharmacologic effects in any subject. The cortex was delineated on PET, and the activity gradually transited to the medulla and then renal pelvis with high spatiotemporal resolution. Conclusion: 11C-PABA demonstrated fast renal excretion with very low background signal in animals and humans. These results suggest that 11C-PABA could be used as a novel radiotracer for functional renal imaging, providing high-quality spatiotemporal images with low radiation exposure. Full Article
health and food 18F-DCFPyL PET/CT in Patients with Subclinical Recurrence of Prostate Cancer: Effect of Lesion Size, Smooth Filter and Partial Volume Correction on Prostate Cancer Molecular Imaging Standardized Evaluation (PROMISE) criteria By jnm.snmjournals.org Published On :: 2020-03-20T13:59:23-07:00 Purpose: To determine the effect of smooth filter and partial volume correction (PVC) method on measured prostate-specific membrane antigen (PSMA) activity in small metastatic lesions and to determine the impact of these changes on the molecular imaging (mi) PSMA scoring. Materials & Methods: Men with biochemical recurrence of prostate cancer with negative CT and bone scintigraphy were referred for 18F-DCFPyL PET/CT. Examinations were performed on one of 2 PET/CT scanners (GE Discovery 610 or Siemens mCT40). All suspected tumor sites were manually contoured on co-registered CT and PET images, and each was assigned a miPSMA score as per the PROMISE criteria. The PVC factors were calculated for every lesion using the anatomical CT and then applied to the unsmoothed PET images. The miPSMA scores, with and without the corrections, were compared, and a simplified "rule of thumb" (RoT) correction factor (CF) was derived for lesions at various sizes (<4mm, 4-7mm, 7-9mm, 9-12mm). This was then applied to the original dataset and miPSMA scores obtained using the RoT CF were compared to those found using the actual corrections. Results: There were 75 men (median age, 69 years; median serum PSA of 3.69 ug/L) with 232 metastatic nodes < 12 mm in diameter (mean lesion volume of 313.5 ± 309.6 mm3). Mean SUVmax before and after correction was 11.0 ± 9.3 and 28.5 ± 22.8, respectively (p<0.00001). The mean CF for lesions <4mm (n = 22), 4-7mm (n = 140), 7-9mm (n = 50), 9-12 mm (n = 20) was 4 (range: 2.5-6.4), 2.8 (range: 1.6-4.9), 2.3 (range: 1.6-3.3) and 1.8 (range 1.4-2.4), respectively. Overall miPSMA scores were concordant between the corrected dataset and RoT in 205/232 lesions (88.4%). Conclusion: There is a significant effect of smooth filter and partial volume correction on measured PSMA activity in small nodal metastases, impacting the miPSMA score. Full Article
health and food Benefit of improved performance with state-of-the art digital PET/CT for lesion detection in oncology By jnm.snmjournals.org Published On :: 2020-03-20T13:59:23-07:00 Latest digital whole-body PET scanners provide a combination of higher sensitivity and improved spatial and timing resolution. We performed a lesion detectability study on two generations of Siemens Biograph PET/CT scanners, the mCT and Vision, to study the impact of improved physical performance on clinical performance. Our hypothesis is that the improved performance of the Vision will result in improved lesion detectability, allowing shorter imaging times or equivalently, lower injected dose. Methods: Data were acquired with the Society of Nuclear Medicine and Molecular Imaging Clinical Trials Network torso phantom combined with a 20-cm diameter cylindrical phantom. Spherical lesions were emulated by acquiring spheres-in-air data, and combining it with the phantom data to generate combined datasets with embedded lesions of known contrast. Two sphere sizes and uptakes were used: 9.89 mm diameter spheres with 6:1 (lung) and 3:1 (cylinder) and 4.95 mm diameter spheres with 9.6:1 (lung) and 4.5:1 (cylinder) local activity concentration uptakes. Standard image reconstruction was performed: ordinary Poisson ordered subsets expectation maximization algorithm with point spread function and time-of-flight modeling and post-reconstruction smoothing with a 5 mm Gaussian filter. The Vision images were also generated without any post-reconstruction smoothing. Generalized scan statistics methodology was used to estimate the area under the localization receiver operating characteristic curve (ALROC). Results: Higher sensitivity and improved TOF performance of Vision leads to reduced contrast in the background noise nodule distribution. Measured lesion contrast is also higher on the Vision due to its improved spatial resolution. Hence, the ALROC values are noticeably higher for the Vision relative to the mCT. Conclusion: Improved overall performance of the Vision provides a factor of 4-6 reduction in imaging time (or injected dose) over the mCT when using the ALROC metric for lesions >9.89 mm in diameter. Smaller lesions are barely detected in the mCT, leading to even higher ALROC gains with the Vision. Improved spatial resolution of the Vision also leads to a higher measured contrast that is closer to the real uptake, implying improved quantification. Post-reconstruction smoothing, however, reduces this improvement in measured contrast, thereby reducing the ALROC values for small, high uptake lesions. Full Article
health and food A Prospective, Comparative Study of Planar and Single-photon Emission Computed Tomography Ventilation/Perfusion Imaging for Chronic Thromboembolic Pulmonary Hypertension By jnm.snmjournals.org Published On :: 2020-03-20T13:59:23-07:00 Objectives: The study compared the diagnostic performance of Planar Ventilation/perfusion (V/Q) and V/Q Single-photon computed tomography (SPECT), and determined whether combining perfusion scanning with low-dose computed tomography (Q-LDCT) may be equally effective in a prospective study of patients with chronic thromboembolic pulmonary hypertension (CTEPH) patients. Background: V/Q scanning is recommended for excluding CTEPH during the diagnosis of pulmonary hypertension (PH). However, Planar V/Q and V/Q SPECT techniques have yet to be compared in patients with CTEPH. Methods: Patients with suspected PH were eligible for the study. PH attributable to left heart disease or lung disease was excluded, and patients whose PH was confirmed by right heart catheterization and who completed Planar V/Q, V/Q-SPECT, Q-LDCT, and pulmonary angiography were included. V/Q images were interpreted and patients were diagnosed as instructed by the 2009 EANM guidelines, and pulmonary angiography analyses were used as a reference standard. Results: A total of 208 patients completed the study, including 69 with CTEPH confirmed by pulmonary angiography. Planar V/Q, V/Q-SPECT, and Q-LDCT were all highly effective for diagnosing CTEPH, with no significant differences in sensitivity or specificity observed among the three techniques (Planar V/Q [sensitivity/specificity]: 94.20%/92.81%; V/Q-SPECT: 97.10%/91.37%, Q-LCDT: 95.65%/90.65%). However, V/Q-SPECT was significantly more sensitive (V/Q-SPECT: 79.21%; Planar V/Q: 75.84%, P = 0.012; Q-LDCT: 74.91%, p<0.001), and Planar V/Q was significantly more specific (Planar V/Q: 54.14%; V/Q-SPECT 46.05%, p<0.001; Q-LDCT: 46.05%, P = 0.001) than the other two techniques for identifying perfusion defects in individual lung segments. Conclusion: Both Planar V/Q and V/Q-SPECT were highly effective for diagnosing CTEPH, and Q-LDCT may be a reliable alternative method for patients who are unsuitable for ventilation imaging. Full Article
health and food Molecular imaging of bone metastases and their response to therapy By jnm.snmjournals.org Published On :: 2020-04-03T15:14:37-07:00 Bone metastases are common, especially in more prevalent malignancies such as breast and prostate cancer. They cause significant morbidity and draw on healthcare resources. Molecular and hybrid imaging techniques, including single photon emission computed tomography with computed tomography (SPECT/CT), positron emission tomography / CT and whole-body MRI with diffusion-weighted imaging (WB-MRI), have improved diagnostic accuracy in staging the skeleton compared to previous standard imaging methods, allowing earlier tailored treatment. With the introduction of several effective treatment options, it is now even more important to detect and monitor response in bone metastases accurately. Conventional imaging, including radiographs, CT, MRI and bone scintigraphy, are recognized as being insensitive and non-specific for response monitoring in a clinically relevant time frame. Early reports of molecular and hybrid imaging techniques, as well as WB-MRI, promise earlier and more accurate prediction of response vs non-response but have yet to be adopted routinely in clinical practice. We summarize the role of new molecular and hybrid imaging methods including SPECT/CT, PET/CT and WB-MRI. These modalities are associated with improvements in diagnostic accuracy for staging and response assessment of skeletal metastases over standard imaging methods, being able to quantify biological processes related to the bone microenvironment as well as tumor cells. The described improvements in the imaging of bone metastases and their response to therapy have led to some being adopted into routine clinical practice in some centers and at the same time provide better methods to assess treatment response of bone metastases in clinical trials. Full Article
health and food 177Lu-lilotomab satetraxetan has the potential to counteract resistance to rituximab in non-Hodgkins lymphoma By jnm.snmjournals.org Published On :: 2020-04-03T15:14:37-07:00 Background: Patients with NHL who are treated with rituximab may develop resistant disease, often associated with changes in expression of CD20. The next generation β-particle emitting radioimmunoconjugate 177Lu-lilotomab-satetraxetan (Betalutin®) was shown to up-regulate CD20 expression in different rituximab-sensitive NHL cell lines and to act synergistically with rituximab in a rituximab-sensitive NHL animal model. We hypothesized that 177Lu-lilotomab-satetraxetan may be used to reverse rituximab-resistance in NHL. Methods: The rituximab-resistant Raji2R and the parental Raji cell lines were used. CD20 expression was measured by flow cytometry. ADCC was measured by a bioluminescence reporter assay. The efficacies of combined treatments with 177Lu-lilotomab-satetraxetan (150MBq/kg or 350MBq/kg) and rituximab (4x10mg/kg) were compared with those of single agents or saline in a Raji2R-xenograft model. Cox-regression and the Bliss independence model were used to assess synergism. Results: Rituximab-binding in Raji2R cells was 36±5% of that in the rituximab-sensitive Raji cells. 177Lu-lilotomab-satetraxetan treatment of Raji2R cells increased the binding to 53±3% of the parental cell line. Rituximab ADCC-induction in Raji2R cells was 20±2% of that induced in Raji cells, while treatment with 177Lu-lilotomab-satetraxetan increased the ADCC-induction to 30±3% of the Raji cells, representing a 50% increase (p<0.05). The combination of rituximab with 350MBq/kg 177Lu-lilotomab-satetraxetan synergistically suppressed Raji2R tumor growth in athymic Foxn1nu mice. Conclusion: 177Lu-lilotomab-satetraxetan has the potential to reverse rituximab-resistance; it increases binding and ADCC-activity in-vitro and can synergistically improve anti-tumor efficacy in-vivo. Full Article
health and food Moving towards multicenter therapeutic trials in ALS: feasibility of data pooling using different TSPO positron emission tomography (PET) radioligands. By jnm.snmjournals.org Published On :: 2020-04-03T15:14:37-07:00 Rationale: Neuroinflammation has been implicated in Amyotrophic Lateral Sclerosis (ALS) and can be visualized using translocator protein (TSPO) radioligands. To become a reliable pharmacodynamic biomarker for ALS multicenter trials, some challenges have to be overcome. We aimed to investigate whether multicenter data pooling of different TSPO tracers (11C-PBR28 and 18F-DPA714) is feasible, after validation of an established 11C-PBR28 PET pseudoreference analysis technique for 18F-DPA714. Methods: 7 ALS-Belgium (58.9±6.7 years,5M) and 8 HV-Belgium (52.1±15.2 years,3M); and 7 ALS-US (53.4±9.8 years,5M) and 7 HV-US (54.6±9.6 years,4M) from a previously published study (1) underwent dynamic 18F-DPA714 (Leuven, Belgium) or 11C-PBR28 (Boston, US) PET-MR scans. For 18F-DPA714, volume of distribution (VT) maps were compared to standardized uptake value ratios (SUVR)40-60 calculated using the pseudoreference regions (1)cerebellum, (2)occipital cortex, and (3)whole brain without ventricles (WB-ventricles). Also for 11C-PBR28, SUVR60-90 using WB-ventricles were calculated. Results: In line with previous studies, increased 18F-DPA714 uptake (17.0±5.6%) in primary motor cortices was observed in ALS, as measured by both VT and SUVR40-60 approaches. Highest sensitivity was found for SUVRWB-ventricles (average cluster 21.6±0.1%). 18F-DPA714 VT ratio and SUVR40-60 results were highly correlated (r>0.8, p<0.001). A similar pattern of increased uptake (average cluster 20.5±0.5%) in primary motor cortices was observed in ALS with 11C-PBR28 using the SUVRWB-ventricles. Analysis of the 18F-DPA714 and 11C-PBR28 data together, resulted in a more extensive pattern of significant increased glial activation in the bilateral primary motor cortices. Conclusion: The same pseudoreference region analysis technique for 11C-PBR28 PET imaging can be extended towards 18F-DPA714 PET. Therefore, in ALS, standardized analysis across these two tracers enables pooling of TSPO PET data across multiple centers and increase power of TSPO as biomarker for future therapeutic trials. Full Article
health and food Data Driven Respiratory Gating Outperforms Device-Based Gating for Clinical FDG PET/CT By jnm.snmjournals.org Published On :: 2020-04-03T15:14:37-07:00 A data-driven method for respiratory gating in PET has recently been commercially developed. We sought to compare the performance of the algorithm to an external, device-based system for oncological [18F]-FDG PET/CT imaging. Methods: 144 whole-body [18F]-FDG PET/CT examinations were acquired using a Discovery D690 or D710 PET/CT scanner (GE Healthcare), with a respiratory gating waveform recorded by an external, device based respiratory gating system. In each examination, two of the bed positions covering the liver and lung bases were acquired with duration of 6 minutes. Quiescent period gating retaining ~50% of coincidences was then able to produce images with an effective duration of 3 minutes for these two bed positions, matching the other bed positions. For each exam, 4 reconstructions were performed and compared: data driven gating (DDG-retro), external device-based gating (RPM Gated), no gating but using only the first 3 minutes of data (Ungated Matched), and no gating retaining all coincidences (Ungated Full). Lesions in the images were quantified and image quality was scored by a radiologist, blinded to the method of data processing. Results: The use of DDG-retro was found to increase SUVmax and to decrease the threshold-defined lesion volume in comparison to each of the other reconstruction options. Compared to RPM-gated, DDG-retro gave an average increase in SUVmax of 0.66 ± 0.1 g/mL (n=87, p<0.0005). Although results from the blinded image evaluation were most commonly equivalent, DDG-retro was preferred over RPM gated in 13% of exams while the opposite occurred in just 2% of exams. This was a significant preference for DDG-retro (p=0.008, n=121). Liver lesions were identified in 23 exams. Considering this subset of data, DDG-retro was ranked superior to Ungated Full in 6/23 (26%) of cases. Gated reconstruction using the external device failed in 16% of exams, while DDG-retro always provided a clinically acceptable image. Conclusion: In this clinical evaluation, the data driven respiratory gating technique provided superior performance as compared to the external device-based system. For the majority of exams the performance was equivalent, but data driven respiratory gating had superior performance in 13% of exams, leading to a significant preference overall. Full Article
health and food Lesion detection and administered activity By jnm.snmjournals.org Published On :: 2020-04-03T15:14:37-07:00 Full Article
health and food FDG-PET assessment of malignant pleural mesothelioma: Total Lesion volume and Total Lesion Glycolysis; the central role of volume. By jnm.snmjournals.org Published On :: 2020-04-13T14:09:24-07:00 Cancer Survival is related to tumor volume. FDG PET measurement of tumor volume holds promise but is not yet a clinical tool. Measurements come in two forms: the total lesion volume (TLV) based on the number of voxels in the tumor and secondly the total lesion glycolysis (TLG) which is the TLV multiplied by the average SUL per voxel of the tumor (SUL is the standardize uptake value normalized for lean mass). In this study we measured tumor volume in patients with malignant pleural mesothelioma (MPM). METHODS: A threshold-based program in IDL was developed to measure tumor volume in FDG PET images. 19 patients with malignant pleural mesothelioma (MPM) were studied before and after two cycles (6 weeks) of chemo-immunotherapy. Measurements included the total lesion volume (TLV), Total Lesion Glycolysis (TLG), the sum of the SULs in the tumor (SUL- total), a measure of total FDG uptake, and the average SUL per voxel. RESULTS: Baseline MPM volumes (TLV) ranged from 11 to 2610 cc. TLG values ranged from 32 to 8552 SUL-cc and were strongly correlated with TLV. While tumor volumes ranged over 3 orders of magnitude, the average SUL per voxel, SUL-average, stayed within a narrow range of 2.4 to 5.3 units. Thus, TLV was the major component of TLG while SUL-average was a minor component and was essentially constant. Further evaluation of SUL-average showed that in this cohort it’s two components SUL-total and tumor volume changed in parallel and were strongly correlated, r= 0.99, p<.01. Thus, whether the tumors were large or small, the FDG uptake as measured by SUL-total was proportional to the total tumor volume. Conclusion: TLG equals TLV multiplied by the average SUL per voxel, essentially TLV multiplied by a constant. Thus TLG, commonly considered a measure of "metabolic activity" in tumors, is also in this cohort a measure of tumor volume. The constancy of SUL per voxel is due to FDG uptake being proportional to tumor volume. Thus, in this study, the FDG uptake was also a measure of volume. Full Article
health and food 3D-Printable Platform for High-Throughput Small-Animal Imaging By jnm.snmjournals.org Published On :: 2020-04-13T14:09:24-07:00 Full Article
health and food Folate Receptor {beta} Targeted PET Imaging of Macrophages in Autoimmune Myocarditis By jnm.snmjournals.org Published On :: 2020-04-13T14:09:24-07:00 Rationale: Currently available imaging techniques have limited specificity for the detection of active myocardial inflammation. Aluminum fluoride-18-labeled 1,4,7-triazacyclononane-N,N',N''-triacetic acid conjugated folate (18F-FOL) is a positron emission tomography (PET) tracer targeting folate receptor β (FR-β) that is expressed on activated macrophages at sites of inflammation. We evaluated 18F-FOL PET for the detection of myocardial inflammation in rats with autoimmune myocarditis and studied expression of FR-β in human cardiac sarcoidosis specimens. Methods: Myocarditis was induced by immunizing rats (n = 18) with porcine cardiac myosin in complete Freund’s adjuvant. Control rats (n = 6) were injected with Freund’s adjuvant alone. 18F-FOL was intravenously injected followed by imaging with a small animal PET/computed tomography (CT) scanner and autoradiography. Contrast-enhanced high-resolution CT or 2-deoxy-2-18F-fluoro-D-glucose (18F-FDG) PET images were used for co-registration. Rat tissue sections and myocardial autopsy samples of 6 patients with cardiac sarcoidosis were studied for macrophages and FR-β. Results: The myocardium of 10 out of 18 immunized rats showed focal macrophage-rich inflammatory lesions with FR-β expression occurring mainly in M1-polarized macrophages. PET images showed focal myocardial 18F-FOL uptake co-localizing with inflammatory lesions (SUVmean, 2.1 ± 1.1), whereas uptake in the remote myocardium of immunized rats and controls was low (SUVmean, 0.4 ± 0.2 and 0.4 ± 0.1, respectively; P < 0.01). Ex vivo autoradiography of tissue sections confirmed uptake of 18F-FOL in myocardial inflammatory lesions. Uptake of 18F-FOL to inflamed myocardium was efficiently blocked by a non-labeled FR-β ligand folate glucosamine in vivo. The myocardium of patients with cardiac sarcoidosis showed many FR-β-positive macrophages in inflammatory lesions. Conclusion: In a rat model of autoimmune myocarditis, 18F-FOL shows specific uptake in inflamed myocardium containing macrophages expressing FR-β, which were also present in human cardiac sarcoid lesions. Imaging of FR-β expression is a potential approach for the detection of active myocardial inflammation. Full Article
health and food Biodistribution of a CD3/EpCAM bispecific T-cell engager is driven by the CD3 arm By jnm.snmjournals.org Published On :: 2020-04-13T14:09:24-07:00 BiTE® (Bispecific T-cell engager) molecules are designed to engage and activate cytotoxic T-cells to kill tumor cells. Little is known about their biodistribution in immunocompetent settings. To explore their pharmacokinetics and the role of the immune cells, BiTE molecules were radiolabeled with positron emission tomography (PET) isotope zirconium-89 (89Zr) and studied in immunocompetent and immunodeficient mouse models. PET images and ex-vivo biodistribution in immunocompetent mice with 89Zr-muS110, targeting mouse CD3 (Kd = 2.9 nM) and mouse EpCAM (Kd = 21 nM), and 89Zr-hyS110, targeting only mouse CD3 (Kd = 2.9 nM), showed uptake in tumor, spleen and other lymphoid organs, while the human-specific control BiTE 89Zr-AMG 110 showed similar tumor uptake but lacked spleen uptake. 89Zr-muS110 spleen uptake was lower in immunodeficient than in immunocompetent mice. After repeated administration of non-radiolabeled muS110 to immunocompetent mice 89Zr-muS110 uptake in spleen, and other lymphoid tissues, decreased and was comparable to uptake in immunodeficient mice, indicating saturation of CD3 binding sites. Autoradiography and immunohistochemistry demonstrated colocalization of 89Zr-muS110 and 89Zr-hyS110 with CD3-positive T-cells in the tumor and spleen but not with EpCAM expression. Also, uptake in the duodenum correlated with a high incidence of T-cells. This study shows that in immunocompetent mice the BiTE 89Zr-muS110 distribution is predominantly based on its high affinity CD3 binding arm. Significance: 89Zr-muS110 biodistribution is mainly dependent on the T-cell targeting arm with limited contribution of its second arm, targeting EpCAM. These findings highlight the need for extensive biodistribution studies of novel bispecific constructs as results might have implications for their respective drug development and clinical translation. Full Article
health and food PET imaging of phosphodiesterase-4 identifies affected dysplastic bone in McCune-Albright syndrome, a genetic mosaic disorder By jnm.snmjournals.org Published On :: 2020-04-13T14:09:24-07:00 McCune-Albright syndrome (MAS) is a mosaic disorder arising from gain-of-function mutations in the GNAS gene, which encodes the 3', 5'-cyclic adenosine monophosphate (cAMP) pathway-associated G-protein, Gsα. Clinical manifestations of MAS in a given individual, including fibrous dysplasia, are determined by the timing and location of the GNAS mutation during embryogenesis, the tissues involved, and the role of Gsα in the affected tissues. The Gsα mutation results in dysregulation of the cAMP signaling cascade, leading to upregulation of phosphodiesterase type 4 (PDE4), which catalyzes the hydrolysis of cAMP. Increased cAMP levels have been found in vitro in both animal models of fibrous dysplasia and in cultured cells from individuals with MAS, but not in humans with fibrous dysplasia. Positron emission tomography (PET) imaging of PDE4 with 11C-(R)-rolipram has been used successfully to study the in vivo activity of the cAMP cascade. To date, it remains unknown whether fibrous dysplasia and other symptoms of MAS, including neuropsychiatric impairments, are associated with increased PDE4 activity in humans. Methods: 11C-(R)-rolipram whole-body and brain PET scans were performed in six individuals with MAS (three for brain scans and six for whole-body scans) and nine healthy controls (seven for brain scans and six for whole-body scans). Results: 11C-(R)-rolipram binding correlated with known locations of fibrous dysplasia in the periphery of individuals with MAS; no uptake was observed in the bones of healthy controls. In peripheral organs and the brain, no difference in 11C-(R)-rolipram uptake was noted between participants with MAS and healthy controls. Conclusion: This study is the first to find evidence for increased cAMP activity in areas of fibrous dysplasia in vivo. No differences in brain uptake between MAS participants and controls were detected, which could be due to several reasons, including the limited anatomic resolution of PET. Nevertheless, the results confirm the usefulness of PET scans with 11C-(R)-rolipram to indirectly measure increased cAMP pathway activation in human disease. Full Article
health and food Assessing the Activity of Multidrug Resistance-Associated Protein 1 at the Lung Epithelial Barrier By jnm.snmjournals.org Published On :: 2020-04-13T14:09:24-07:00 Multidrug resistance-associated protein 1 (ABCC1) is abundantly expressed at the lung epithelial barrier, where it may influence the pulmonary disposition of inhaled drugs and contribute to variability in therapeutic response. Aim of this study was to assess the impact of ABCC1 on the pulmonary disposition of 6-bromo-7-11C-methylpurine (11C-BMP), a prodrug radiotracer which is intracellularly conjugated with glutathione to form the ABCC1 substrate S-(6-(7-11C-methylpurinyl))glutathione (11C-MPG). Methods: Groups of Abcc1(-/-) rats, wild-type rats pretreated with the ABCC1 inhibitor MK571 and wild-type control rats underwent dynamic PET scans after administration of 11C-BMP intravenously (i.v.) or by intratracheal aerosolization (i.t.). In vitro transport experiments were performed with unlabeled BMP in the human distal lung epithelial cell line NCI-H441. Results: Pulmonary kinetics of radioactivity were significantly different between wild-type and Abcc1(-/-) rats, but differences were more pronounced after i.t. than after i.v. administration. After i.v. administration lung exposure (AUClung) was 77% higher and the elimination slope of radioactivity washout from the lungs (kE,lung) was 70% lower, whereas after i.t. administration AUClung was 352% higher and kE,lung was 86% lower in Abcc1(-/-) rats. Pretreatment with MK571 decreased kE,lung by 20% after i.t. radiotracer administration. Intracellular accumulation of MPG in NCI-H441 cells was significantly higher and extracellular efflux was lower in presence than in absence of MK571. Conclusion: PET with pulmonary administered 11C-BMP can measure ABCC1 activity at the lung epithelial barrier and may be applicable in humans to assess the effects of disease, genetic polymorphisms or concomitant drug intake on pulmonary ABCC1 activity. Full Article
health and food Repurposing Molecular Imaging and Sensing for Cancer Image-Guided Surgery By jnm.snmjournals.org Published On :: 2020-04-17T08:32:41-07:00 Gone are the days when medical imaging was used primarily to visualize anatomical structures. The emergence of molecular imaging, championed by radiolabeled fluorodeoxyglucose positron emission tomography (18FDG PET) has expanded the information content derived from imaging to include pathophysiological and molecular processes. Cancer imaging, in particular, has leveraged advances in molecular imaging agents and technology to improve the accuracy of tumor detection, interrogate tumor heterogeneity, monitor treatment response, focus surgical resection, and enable image-guided biopsy. Surgeons are actively latching on to the incredible opportunities provided by medical imaging for preoperative planning, intraoperative guidance, and postoperative monitoring. From label-free techniques to enabling cancer-selective imaging agents, image-guided surgery provides surgical oncologists and interventional radiologists both macroscopic and microscopic views of cancer in the operating room. This review highlights the current state of molecular imaging and sensing approaches available for surgical guidance. Salient features of nuclear, optical, and multimodal approaches will be discussed, including their strengths, limitations and clinical applications. To address the increasing complexity and diversity of methods available today, this review provides a framework to identify a contrast mechanism, suitable modality, and device. Emerging low cost, portable, and user-friendly imaging systems make the case for adopting some of these technologies as the global standard of care in surgical practice. Full Article
health and food The Changing Face of Nuclear Cardiology: Guiding Cardiovascular Care towards Molecular Medicine By jnm.snmjournals.org Published On :: 2020-04-17T08:32:41-07:00 Radionuclide imaging of myocardial perfusion, function, and viability has been established for decades and remains a robust, evidence-based and broadly available means for clinical workup and therapeutic guidance in ischemic heart disease. Yet, powerful alternative modalities have emerged for this purpose, and their growth has resulted in increasing competition. But the potential of the tracer principle goes beyond the assessment of physiology and function, towards the interrogation of biology and molecular pathways. This is a unique selling point of radionuclide imaging, which has been under-recognized in cardiovascular medicine until recently. Now, molecular imaging methods for the detection of myocardial infiltration, device infection and cardiovascular inflammation are successfully gaining clinical acceptance. This is further strengthened by the symbiotic quest of cardiac imaging and therapy for an increasing implementation of molecular-targeted procedures, where specific therapeutic interventions require specific diagnostic guidance towards the most suitable candidates. This review will summarize the current advent of clinical cardiovascular molecular imaging and highlight its transformative contribution to the evolution of cardiovascular therapy beyond mechanical interventions and broad "blockbuster" medication, towards a future of novel, individualized molecular targeted and molecular imaging-guided therapies. Full Article
health and food Factors predicting metastatic disease in 68Ga-PSMA-11 PET positive osseous lesions in prostate cancer By jnm.snmjournals.org Published On :: 2020-04-17T08:32:41-07:00 Bone is the most common site of distant metastatic spread in prostate adenocarcinoma. Prostate-specific membrane antigen uptake has been described in both benign and malignant bone lesions, which can lead to false-positive findings on 68Ga-prostate-specific membrane antigen-11 positron emission tomography (68Ga-PSMA-11 PET). The purpose of this study was to evaluate the diagnostic accuracy of 68Ga-PSMA-11 PET for osseous prostate cancer metastases and improve bone uptake interpretation using semi-quantitative metrics. METHODS: 56 prostate cancer patients (18 pre-prostatectomy, 38 biochemical recurrence) who underwent 68Ga-PSMA-11 PET/MRI or PET/CT examinations with osseous PSMA-ligand uptake were included in the study. Medical records were reviewed retrospectively by board-certified nuclear radiologists to determine true or false positivity based on a composite endpoint. For each avid osseous lesion, biological volume, size, PSMA-RADS rating, maximum standardized uptake value (SUVmax), and ratio of lesion SUVmax to liver, blood pool, and background bone SUVmax were measured. Differences between benign and malignant lesions were evaluated for statistical significance, and cut-off values for these parameters were determined to maximize diagnostic accuracy. RESULTS: Among 56 participants, 13 patients (22.8%) had false-positive osseous 68Ga-PSMA-11 findings and 43 patients (76.8%) had true-positive osseous 68Ga-PSMA-11 findings. Twenty-two patients (39%) had 1 osseous lesion, 18 (32%) had 2-4 lesions, and 16 (29%) had 5 or more lesions. Cut-off values resulting in statistically significant (p<0.005) differences between benign and malignant lesions were: PSMA-RADS ≥4, SUVmax ≥4.1, SUVmax ratio of lesion to blood pool ≥2.11, to liver ≥0.55, and to bone ≥4.4. These measurements corresponded to lesion-based 68Ga-PSMA-11 PET lesion detection rate for malignancy of 80%, 93%, 89%, 21%, 89%, and a specificity of 73%, 73%, 73%, 93%, 60%, respectively. CONCLUSION: PSMA-RADS rating, SUVmax, and SUVmax ratio of lesion to blood pool can help differentiate benign from malignant lesions on 68Ga-PSMA-11 PET. SUVmax ratio to blood pool above 2.2 is a reasonable parameter to support image interpretation and presented superior lesion detection rate and specificity when compared to visual interpretation by PSMA RADS. These parameters hold clinical value by improving diagnostic accuracy for metastatic prostate cancer on 68Ga-PSMA-11 PET/MRI and PET/CT. Full Article
health and food The role of Nuclear Medicine for COVID-19 - Time to act now. By jnm.snmjournals.org Published On :: 2020-04-17T08:32:41-07:00 Full Article
health and food Letter to the Editor: Who was the first doctor to report the Covid-19 outbreak in Wuhan, China? By jnm.snmjournals.org Published On :: 2020-04-17T08:32:41-07:00 Full Article
health and food MITIGATE-NeoBOMB1, a Phase I/IIa Study to Evaluate Safety, Pharmacokinetics and Preliminary Imaging of 68Ga-NeoBOMB1, a Gastrin-releasing Peptide Receptor Antagonist, in GIST Patients By jnm.snmjournals.org Published On :: 2020-04-24T14:33:41-07:00 Introduction: Gastrin Releasing peptide receptors (GRPRs) are potential molecular imaging targets in a variety of tumors. Recently, a 68Ga-labelled antagonist to GRPRs, NeoBOMB1, was developed for PET. We report on the outcome of a Phase I/IIa clinical trial (EudraCT 2016-002053-38) within the EU-FP7 project Closed-loop Molecular Environment for Minimally Invasive Treatment of Patients with Metastatic Gastrointestinal Stromal Tumours (‘MITIGATE’) (grant agreement number 602306) in patients with oligometastatic gastrointestinal stromal tumors (GIST). Materials and Methods: The main objectives were evaluation of safety, biodistribution, dosimetry and preliminary tumor targeting of 68Ga-NeoBOMB1 in patients with advanced TKI-treated GIST using PET/CT. Six patients with histologically confirmed GIST and unresectable primary or metastases undergoing an extended protocol for detailed pharmacokinetic analysis were included. 68Ga-NeoBOMB1 was prepared using a kit procedure with a licensed 68Ge/68Ga generator. 3 MBq/kg body-weight were injected intravenously and safety parameters were assessed. PET/CT included dynamic imaging at 5 min, 11 min and 19 min as well as static imaging at 1, 2 and 3-4 h p.i. for dosimetry calculations. Venous blood samples and urine were collected for pharmacokinetics. Tumor targeting was assessed on a per-lesion and per-patient basis. Results: 68Ga-NeoBOMB1 (50 µg) was prepared with high radiochemical purity (yield >97%). Patients received 174 ± 28 MBq of the radiotracer, which was well tolerated in all patients over a follow-up period of 4 weeks. Dosimetry calculations revealed a mean adsorbed effective dose of 0.029 ± 0.06 mSv/MBq with highest organ dose to the pancreas (0.274 ± 0.099 mSv/MBq). Mean plasma half-life was 27.3 min with primarily renal clearance (mean 25.7 ± 5.4% of injected dose 4h p.i.). Plasma metabolite analyses revealed high stability, metabolites were only detected in the urine. In three patients a significant uptake with increasing maximum standard uptake values (SUVmax at 2h p.i.: 4.3 to 25.9) over time was found in tumor lesions. Conclusion: This Phase I/IIa study provides safety data for 68Ga-NeoBOMB1, a promising radiopharmaceutical for targeting GRPR-expressing tumors. Safety profiles and pharmacokinetics are suitable for PET imaging and absorbed dose estimates are comparable to other 68Ga-labelled radiopharmaceuticals used in clinical routine. Full Article
health and food CXCR4-targeted positron emission tomography imaging of central nervous system B-cell lymphoma By jnm.snmjournals.org Published On :: 2020-04-24T14:33:41-07:00 C-X-C chemokine receptor 4 is a transmembrane chemokine receptor involved in growth, survival, and dissemination of cancer, including aggressive B-cell lymphoma. Magnetic resonance imaging (MRI) is the standard imaging technology for central nervous system involvement of B-cell lymphoma and provides high sensitivity but moderate specificity. Therefore, novel molecular and functional imaging strategies are urgently required. Methods: In this proof-of-concept study, 11 patients with lymphoma of the CNS (CNSL, n = 8 primary and n = 3 secondary involvement) were imaged with the CXCR4-directed positron emission tomography (PET) tracer 68Ga-Pentixafor. To evaluate the predictive value of this imaging modality, treatment response, as determined by MRI, was correlated with quantification of CXCR4 expression by 68Ga-Pentixafor PET in vivo before initiation of treatment in 7 of 11 patients. Results: 68Ga-Pentixafor-PET showed excellent contrast characteristics to the surrounding brain parenchyma in all patients with active disease. Furthermore, initial CXCR4 uptake determined by PET correlated with subsequent treatment response as assessed by MRI. Conclusion: 68Ga-Pentixafor-PET represents a novel diagnostic tool for central nervous system lymphoma with potential implications for theranostic approaches as well as response and risk assessment. Full Article