pspice

Using oscillograph waveform file CSV as the Pspice simulation signal source

hi,

     I save the waveform file of the oscilloscope as CSV file format.

     Now, I need to use this waveform file as the source of the low-pass filter .

     I searched and read the PSPICE help documents, and did not find any  methods. 

     How to realize it?

     Are there any reference documents or examples?

     Thanks!

    




pspice

Matlab cannot open Pspice, to prompt orCEFSimpleUI.exe that it has stopped working!

Cadence_SPB_17.4-2019 + Matlab R2019a

请参考本文档中的步骤进行操作

1,打开BJT_AMP.opj

2,设置Matlab路径

3,打开BJT_AMP_SLPS.slx

4,打开后,设置PSpiceBlock,出现或CEFSimpleUI.exe停止工作

5,添加模块

6,相同

7,打开pspsim.slx

8,相同

9,打开C: Cadence Cadence_SPB_17.4-2019 tools bin

orCEFSimpleUI.exe和orCEFSimple.exe

 

10,相同

我想问一下如何解决,非常感谢!




pspice

How to use PSpice library in Virtuoso/Spectre?

I want to use PSpice model (download from TI) in Virtuoso , but it can not work. Please help me to check the error message, Thanks

ADE-> Setup-> simulation files->Pspice  Files  /TPS628502-Q1_TRANS.LIB

Parse error before token ']' in expression '[[STEADY_STATE]*0.6]'. If '[[STEADY_STATE]*0.6]'  is a spice expression, quotes are required for the expression.

ERROR(SFE-46): An instance of 'TPS628502-Q1_TRANS'  can have at most 8 terminals (but has 9).

*****************************************************************************
.SUBCKT TPS628502-Q1_TRANS COMP_FSET EN FB GND PG SW SYNC_MODE VIN
+ PARAMS: STEADY_STATE=0
V_U9_V45 U9_N16725824 0 5
E_U9_ABM22 U9_N16725392 0 VALUE { V(FREQ)*1e-12 }
X_U9_U161 U9_N16849713 U9_N16846056 one_shot PARAMS: T=20




pspice

Is it possible to find or create a Pspice model for the JT3028, LD7552 components?

I would like to add these components to the component bank in ORCAD simulation. Even an accessible or free course that explained how to create these components.




pspice

OrCAD PCB Designer Pro w/ PSpice, Design Object Find Filter Greyed Out

Hello All,

I'm currently using OrCAD PCB Designer Professional w/ PSpice (version 16.6-2015).  In the 'Design Object Find Filter' side bar, all options are grayed out and unselectable.  I did attempt to 'Reset UI to Cadence Default' without any luck.  A colleague has no issues with the identical file on his computer.  Any guidance would be much appreciated.  Thanks!

George




pspice

Matlab cannot open Pspice, to prompt orCEFSimpleUI.exe that it has stopped working!

Cadence_SPB_17.4-2019 + Matlab R2019a

请参考本文档中的步骤进行操作

1,打开BJT_AMP.opj

2,设置Matlab路径

3,打开BJT_AMP_SLPS.slx

4,打开后,设置PSpiceBlock,出现或CEFSimpleUI.exe停止工作

5,添加模块

6,相同

7,打开pspsim.slx

8,相同

9,打开C: Cadence Cadence_SPB_17.4-2019 tools bin

orCEFSimpleUI.exe和orCEFSimple.exe

 

10,相同

我想问一下如何解决,非常感谢!