17.4 Amazon: Operating income increased to $17.4 billion in the third quarter By postandparcel.info Published On :: Fri, 01 Nov 2024 03:04:52 +0000 Amazon.com, Inc has announced financial results for its third quarter ended September 30, 2024. Full Article E-Commerce Parcel
17.4 The Oligonucleotide Synthesis Market was is expected to grow US$ 17.43 Bn by 2030, as per Maximize Market Research. By www.emailwire.com Published On :: Thu, 24 Oct 2024 00:00:00 -0700 (EMAILWIRE.COM, October 24, 2024 ) The oligonucleotide synthesis market is experiencing significant growth due to its applications in diagnostics, therapeutics, and research. North America holds the largest market share due to established research infrastructure and strong demand. Asia Pacific... Full Article
17.4 SPB17.4 installation package build defect By community.cadence.com Published On :: Thu, 09 Dec 2021 23:05:50 GMT 1, Some components in the installation package cannot choose to install; even if they do not choose them, they will still be installed; just less shortcut icons, the documents are still released to the installation directory. 2, "Catia Application Frame" repeat the problem? “x:CadenceSPB_17.4 oolsin“ ”x:CadenceSPB_17.4 oolsspatial“ "Catia Application Frame" shouldn't you use the latest version? 3,Follow-up update patch cleaning the useless files and extra empty folder action !!! The SPB17.4 installation package is currently the worst installation package I have seen for large-scale software packaging. Full Article
17.4 17.4 Design Sync Fails without providing errors By community.cadence.com Published On :: Tue, 14 Dec 2021 14:06:09 GMT As the title suggests I am unable to perform design sync between OrCAD Capture and Allegro. When I add a layout and try to sync to it I am given ERROR(ORCAP-2426): Cannot run Design Sync because of errors. See session log for error details. Session Log [ORPCBFLOW] : Invoking ECO dialog.INFO(ORNET-1176): Netlisting the designINFO(ORNET-1178): Design Name:C:USERSDDOYLEDOCUMENTSCADENCEBOARDSREMOTE POWER DEVICECAPTUREREMOTE_POWER_DEVICE.DSNNetlist Directory:c:usersddoyledocumentscadenceoards emote power devicelayoutallegroConfiguration File:C:CadenceSPB_17.4 ools/capture/allegro.cfgpstswp.exe - pst - d "C:USERSDDOYLEDOCUMENTSCADENCEBOARDSREMOTE POWER DEVICECAPTUREREMOTE_POWER_DEVICE.DSN"- n "c:usersddoyledocumentscadenceoards emote power devicelayoutallegro" - c "C:CadenceSPB_17.4 ools/capture/allegro.cfg" - v 3 - l 31 - s "" - j "PCB Footprint" - hpath "HPathForCollision"Spawning... pstswp.exe - pst - d "C:USERSDDOYLEDOCUMENTSCADENCEBOARDSREMOTE POWER DEVICECAPTUREREMOTE_POWER_DEVICE.DSN"- n "c:usersddoyledocumentscadenceoards emote power devicelayoutallegro" - c "C:CadenceSPB_17.4 ools/capture/allegro.cfg" - v 3 - l 31 - s "" - j "PCB Footprint" - hpath "HPathForCollision"{ Using PSTWRITER 17.4.0 d001Dec-14-2021 at 09:00:49 } INFO(ORCAP-36080): Scanning netlist files ... Loading... c:usersddoyledocumentscadenceoards emote power devicelayoutallegropstchip.dat Loading... c:usersddoyledocumentscadenceoards emote power devicelayoutallegropstchip.dat Loading... c:usersddoyledocumentscadenceoards emote power devicelayoutallegropstxprt.dat Loading... c:usersddoyledocumentscadenceoards emote power devicelayoutallegropstxnet.datpackaging the design view...Exiting... pstswp.exe - pst - d "C:USERSDDOYLEDOCUMENTSCADENCEBOARDSREMOTE POWER DEVICECAPTUREREMOTE_POWER_DEVICE.DSN"- n "c:usersddoyledocumentscadenceoards emote power devicelayoutallegro" - c "C:CadenceSPB_17.4 ools/capture/allegro.cfg" - v 3 - l 31 - s "" - j "PCB Footprint" - hpath "HPathForCollision"INFO(ORNET-1179): *** Done *** This issue started to occur after I changed parts that exist on previously created PCBs. I changed the following leading up to this: 1. Added height in Allegro to many of my components using the Setup->Area->Package Height tool. 2. Changed the reference designator category in OrCAD Capture to TP for several components on board. Any advice here would be most welcome. Thanks! Full Article
17.4 Allegro 17.4 always reports new files as created in 17.2 By community.cadence.com Published On :: Wed, 15 Dec 2021 22:17:58 GMT Hello. I am using Cadence 17.4 tools. When I open a package symbol (.dra) or board file (.brd) in Allegro that was created in an older version of the tool I get a message like this one (as expected): "The design created using release 17.2 will be updated for compatibility with the current software..." If I create a symbol or board file from scratch in the 17.4 tool then open it later, I get the same message. (always referring to version 17.2 which is the previous version I was using here). So far this has not caused me any problems, but I would like to understand why it is doing this in case I have something setup incorrectly. I only have version 17.4 installed. I am not exporting to a downrev version when I save (i.e. not using File->Export->Downrev design…) and in User Preferences->Drawing I don’t have anything selected for database_compatibility_mode. What else might I check? FYI here is the tool version information that I see after selecting Help->About Symbol: OrCAD PCB Designer Standard 17.4-2019 S012 [10/26/2020] Windows SPB 64-bit Edition Thanks -Jason Full Article
17.4 No windows cascading in OrCAD Capture 17.4 By community.cadence.com Published On :: Tue, 21 Dec 2021 08:02:37 GMT Hello All, I'm a novice to this forum and probably this subject has been already discussed here. My company has purchased OrCAD Capture 17.4 tools that have a new GUI if compared to my earlier used OrCAD Capture 9.2. I have been using Capture 9.2 for ~18 years and its GUI is really convenient. The GUI of 17.4 looks to be a modern one with new icons and really has improved features and new capabilities. However, my main complain about GUI 17.4 is that the schematic windows cannot be cascaded. Although they can be set floating, this is even more annoying because all toolbars remain in the Capture window and when you select a tool, the Capture window pops over already open schematic window and you need a lot of useless extra clicks to return back to the currently edited schematic page. I always used cascading of schematic windows before because my complex designs includes many pages, not speaking about the library windows that are typically open simulatneously. My view is that the lack of CASCADING in Capture GUI 17.4 is critical and unacceptable for complex projects, and I would very highly appreciate if the Cadence guys will return back the CASCADING capability for schematic pages. In case this will be done, this will make the GUI really great and comfortable to use. Does anybody have opinion on this issue? Many thanks, Pavel Full Article
17.4 Version upgrade 17.2 to 17.4 - Cadance orcad capture By community.cadence.com Published On :: Tue, 21 Dec 2021 10:49:08 GMT hello, We have a number of workstations with version 17.2 that work on a floating license server We want to know if it can be upgraded to version 17.4 If so, should the floating license server be upgraded as well? In addition, how can you know where the license was purchased from? Thanks! Full Article
17.4 UI issues of PCB Environment Editor 17.4 By community.cadence.com Published On :: Sun, 26 Dec 2021 14:04:11 GMT Hi, I found that under the Dark Theme of PCB Environment Editor 17.4, the window background is not all dark, resulting in unclear text display。 As shown in the figure below: Full Article
17.4 Skill : Draw Line 17.2 works , 17.4 doesn't By feedproxy.google.com Published On :: Mon, 09 Mar 2020 08:21:00 GMT Hi , I am sharing with you some simple skill script that draw line in user layer : axlCmdRegister("DrawLine" 'DrawLine)procedure(DrawLine() layer_name = "substrate geometry/userlayer" mypopup = axlUIPopupDefine(nil '( ("Done" "axlDBTransactionCommit(mark), axlFinishEnterFun()") ("Oops" "axlDBTransactionOops(mark), when(zerop(--oopsNum)") ("Cancel" "axlDBTransactionRollback(mark), axlCancelEnterFun()") ("MENU_SEPARATOR", nil))) axlUIPopupSet( mypopup) ; Clear the dynamic buffer axlClearDynamics() if(axlLayerGet(layer_name) != nil then if(axlIsVisibleLayer(layer_name) == nil then axlVisibleLayer(layer_name,t) axlVisibleUpdate(t) );End if else if(axlLayerGet("substrate geometry") == nil then layer_name = "board geometry/userlayer" axlLayerCreateNonConductor(layer_name) axlVisibleLayer(layer_name,t) axlVisibleUpdate(t) else axlLayerCreateNonConductor(layer_name) axlVisibleLayer(layer_name,t) axlVisibleUpdate(t) );End if );End if ; Clear mypath to nil, then loop gathering user picks: mypath = nil mark = axlDBTransactionStart() flag = t allP = list(nil) seg1 = nil seg2 = nil while( (mypath = axlEnterPath(?lastPath mypath)) if(flag == t then p = axlDBCreatePath(mypath, layer_name) seg1 = car(car(car(p))->segments) seg2 = car(cdr(car(car(p))->segments)) path = axlPathStart( list(car(seg1->startEnd)) , 0) axlPathLine( path , 0 , car(cdr(seg1->startEnd))) if(seg2 then axlPathLine( path , 0 , car(cdr(seg2->startEnd))) );end if flag = nil else p = axlDBCreatePath(mypath, layer_name) seg1 = car(car(car(p))->segments) seg2 = car(cdr(car(car(p))->segments)) axlPathLine( path , 0 , car(cdr(seg1->startEnd))) if(seg2 then axlPathLine( path , 0 , car(cdr(seg2->startEnd))) );end if );end if allP = cons(car(car(p)) allP) );Loop axlDBCreatePath(path, layer_name) forall( x allP axlDeleteObject(x)));End procedure Is anyone can help to understand why this script can work with 16.5/16.6/17.2 and doesn't work with 17.4 ? To be more informative in 17.4 this script behaves differently , when i am trying to draw line i can't zoom in/out ,i can't use my shortcuts to snap it on segment/middle/edge , it's like it's waiting only for next X/Y user click , all other functions just disabled . Thanks . Full Article
17.4 Everton open talks with Barcelona over £17.4m deal for Jean-Clair Todibo By www.dailymail.co.uk Published On :: Tue, 28 Apr 2020 08:49:55 GMT The 20-year old has been long term target for Everton who nearly signed him in January, only for him to join Bundesliga side Schalke on loan for the rest of the season instead. Full Article